Haier GV270REMB User Manual - Page 8

Operation instructions, Troubleshooting, Packing list

Page 8 highlights

Operation instructions Troubleshooting Packing list Operations 1)Before using water, the manual valve, mixing valve (hot water) and mixing valve (cold water) should be closed. 2)To fill water, use automatic function on the controller,or open the manual valve. 3)When using manual valve,when water flows from the overflow pipe, it indicates the water tank is full. Close the manual valve to finish filling water. 4)To use water, open the mixing valve (hot water) and the water comes from the shower nozzle. If the water is too hot, open the mixing value (cold water) to adjust the water temperature. 5)After use of water, make sure the manual valve and mixing valves are closed. Sensor Electric heating tube Over flow port Air supply hole Sensor wire Electric heating wire Accompanying heating strap Outdoor Indoor controller Inlet/outlet pipe plug Mixing valve (hot water) Non-return valve Solenoid valve wire Solenoid valve Manual valve Tap water Troubleshooting Mixing valve (cold water) Phenomena Possible causes Solutions The tank is empty Add water according to the tank The pipeline or the connector falls off or is blocked Maintain the pipeline or remove the blockage No water supply In the winter, water in the feeding/outgoing pipe Start the accompanying heating strap may become frozen or wait for natural ice-out. The vacuum tube is damaged Replace the tube Tap water supply stopped or low water pressure Wait for normal water supply No water from Pipeline or connector may become broken Repair or replace the pipeline or connector the overflow In the winter, water in the feeding/outgoing pipe Start the accompanying heating strap pipe May become frozen or wait for natural ice-out. In bad weather or winter when the sun is relatively low, the sunlight time is short, atmosphere quality is Use auxiliary electric heating as an The temperature poor, and sunshine radiation energy is insufficient option is not high enough The valve for water supply is loose or damaged Tighten or replace the valve The vacuum tube cannot effectively collect heat Remove the blockage or change the due to a blockage in front of it location for installatio Dust on the tube Clean the tube surface Packing list Main parts Water tank (PC) Water tank Manual (Copy) package Tank support (PC) GV150REMB 1 1 2 Quantity GV200REMB 1 1 2 GV270REMB 1 1 3 Sensor (PC) 1 1 1 Glass vacuum tube (PC) 16 22 30 Frame (set) 1 1 1 Controller (set) 1 1 1 0040503720

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Operations
Operation instructions
Troubleshooting
Packing list
Troubleshooting
16
22
30
1
1
1
1
1
1
1
1
1
2
2
3
1
1
1
1
1
1
Packing list
1)Before using water, the manual valve, mixing
valve (hot water) and mixing valve (cold
water) should be closed.
2)To fill water,
3)
,when water flows
from the overflow pipe, it indicates the water
tank is full. Close the manual valve to finish
filling
water.
4)To use water, open the mixing valve (hot
water) and the water comes from the
shower nozzle. If the water is too hot, open
the mixing value (cold water) to adjust the
water temperature.
5)After use of water, make sure the manual
valve and mixing valves are closed.
use automatic function on the
controller,or open the manual valve.
When using manual valve
Phenomena
No water supply
No water from
the overflow
pipe
The temperature
is not high
enough
Possible causes
The tank is empty
The pipeline or the connector falls off or is blocked
In the winter, water in the feeding/outgoing pipe
may become frozen
The vacuum tube is damaged
Tap water supply stopped or low water pressure
Pipeline or connector may become broken
In the winter, water in the feeding/outgoing pipe
May become frozen
In bad weather or winter when the sun is relatively
low, the sunlight time is short, atmosphere quality is
poor, and sunshine radiation energy is insufficient
The valve for water supply is loose or damaged
The vacuum tube cannot effectively collect heat
due to a blockage in front of it
Dust on the tube
Solutions
Add water according to the tank
Start the accompanying heating strap
or wait for natural ice-out.
Replace the tube
Wait for normal water supply
Repair or replace the pipeline or connector
Start the accompanying heating strap
or wait for natural ice-out.
Use auxiliary electric heating as an
option
Tighten or replace the valve
Remove the blockage or change the
location for installatio
Clean the tube surface
Main parts
Quantity
Water tank
package
Water tank (PC)
Sensor (PC)
Manual (Copy)
Tank support (PC)
Glass vacuum tube (PC)
Frame (set)
Controller (set)
Maintain the pipeline or remove the blockage
GV150REMB
GV200REMB
GV270REMB
0040503720
Mixing valve (cold water)
Electric heating wire
Sensor wire
Inlet/outlet
pipe
Mixing valve
(hot water)
Solenoid valve
Solenoid valve wire
Non-return
valve
Manual valve
plug
Outdoor
Tap water
Air supply hole
controller
Indoor
Electric
heating
tube
Accompanying
heating
strap
Over flow port
Sensor