Gigabyte GE-M550A-D1 User Manual - Page 13
Protection, 11 Environment
View all Gigabyte GE-M550A-D1 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
English t 1: TURN-ON DELAY TIME t 2: RISE TIME t 3: POWER GOOD DELAY t 4: POWER FAIL DELAY t 5: HOLD-UP TIME 2-10 PROTECTION When OCP, OVP, OTP, or short protection is triggered, the main output will be latched off. The main outputs can be reset by cycling the DC remote on/off or AC power +5Vsb output is automatically recovered when a fault condition is removed. 2-10-1.OVER CURRENT PROTECTION No exceeding 240VA every output voltage (Beside of 12V) +12V1, +12V2 output 25A max (GE-S800A-D1; GE-M800A-D1; GE-S680A-D1; GE-M680A-D1) +12V3, +12V4 output 38A max (GE-S800A-D1; GE-M800A-D1; GE-S680A-D1; GE-M680A-D1) 2-10-2.OVER VOLTAGE PROTECTION +3.3V output 4.5V max. +5.0V output 7.0V max. +12.0V output 15.6V max. 2-10-3.UNDER VOLTAGE PROTECTION 12V1 & 12V2 output 9.5V min 12V3 & 12V4 output 9.5V min +5V output 4.1V min +3.3V output 2.55V min 2-10-4.SHORT PROTECTION All output to GND 2-10-5.OVER TEMPERATURE PROTECTION The power supply includes an over- temperature sensor, which can trip and shutdown the power supply at 100°C. Such an overheated condition is typically the result of internal current overloading or a cooling fan failure. 2-11 ENVIRONMENT 2-11-1 Operating Temp 13