GE PVW7361SJSS Installation Instructions - Page 2
INSTALLATION PREPARATION, Installation Preparation
View all GE PVW7361SJSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
INSTALLATION PREPARATION 21-1/4" 26-1/2" Min - 37-1/2" Max. Installation Preparation PRODUCT DIMENSIONS 10-1/4" 2-9/16" 4-15/16" 4-15/16" 11-13/16" INSTALLATION CLEARANCES These vent hoods are designed to be installed onto a wall with no above cabinets. • Install these hoods between the 24" required minimum and 36" recommended maximum above the cooking surface. 15-3/4" 30" to 36" 15-3/4" 1/4" 14-3/16" 1-7/16" 24" Required Min. 36" Recommended Max. 18-1/2" 14-3/16" The vent hood must be installed between the 24" required minimum and 36" recommended maximum above the cooking surface. The hood installation height above the cooking surface depends upon ceiling height and duct cover limitations. The telescopic duct cover conceals the ductwork running from the top of the hood to the ceiling. For supplied duct cover ceiling heights, see table on page 5. NOTE: Installation height should be measured from the cooking surface to the lowest part of the hood. This hood must be installed onto a wall. It can be vented to the outdoors, or it can be installed for recirculating operation. For recirculation operation, see Recirculation Install Planning. 2 31-11007