INSTALLATION PREPARATION 21-1/4" 26-1/2" Min - 37-1/2" Max. Installation Preparation PRODUCT DIMENSIONS 10-1/4" 2-9/16" 4-15/16" 4-15/16" 11-13/16" INSTALLATION CLEARANCES These vent hoods are designed to be installed onto a wall with no above cabinets. • Install these hoods between the 24" required minimum and 36" recommended maximum above the cooking surface. 15-3/4" 30" to 36" 15-3/4" 1/4" 14-3/16" 1-7/16" 24" Required Min. 36" Recommended Max. 18-1/2" 14-3/16" The vent hood must be installed between the 24" required minimum and 36" recommended maximum above the cooking surface. The hood installation height above the cooking surface depends upon ceiling height and duct cover limitations. The telescopic duct cover conceals the ductwork running from the top of the hood to the ceiling. For supplied duct cover ceiling heights, see table on page 5. NOTE: Installation height should be measured from the cooking surface to the lowest part of the hood. This hood must be installed onto a wall. It can be vented to the outdoors, or it can be installed for recirculating operation. For recirculation operation, see Recirculation Install Planning. 2 31-11007

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

2
31-11007
INSTALLATION PREPARATION
Installation Preparation
INSTALLATION CLEARANCES
These vent hoods are designed to be installed
onto a wall with no above cabinets.
Install these hoods between the 24” required
minimum and 36” recommended maximum
above the cooking surface.
The vent hood must be installed between the
24” required minimum and 36” recommended
maximum above the cooking surface. The hood
installation height above the cooking surface
depends upon ceiling height and duct cover
limitations. The telescopic duct cover conceals
the ductwork running from the top of the hood
to the ceiling.
For supplied duct cover ceiling
heights, see table on page 5.
NOTE:
Installation height should be measured
from the cooking surface to the lowest part
of the hood. This hood must be installed onto
a wall. It can be vented to the outdoors, or it
can be installed for recirculating operation. For
recirculation operation, see
Recirculation Install
Planning
.
24” Required Min.
36” Recommended Max.
PRODUCT DIMENSIONS
30” to 36”
15-3/4”
15-3/4”
18-1/2”
14-3/16”
14-3/16”
1-7/16"
1/4"
21-1/4”
26-1/2" Min - 37-1/2" Max.
11-13/16”
10-1/4”
2-9/16”
4-15/16”
4-15/16”