GE JVX3300SJSS Use and Care Manual - Page 14
Power Supply, Advance Planning
![]() |
View all GE JVX3300SJSS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
INSTALLATION PREPARATION Installation Preparation ADVANCE PLANNING Vented Install Planning • This hood is designed to be vented vertically using a 7" round duct or a 3 1»4" x 10" rectangular duct or horizontally using a 3 1»4" x 10" rectangular duct. • Use metal ductwork only. • Determine the exact location of the vent hood. • Plan the route for venting exhaust to the outdoors. To maximize the ventilation performance of the vent system: 1. Minimize the duct run length and number of transitions and elbows. 2. Maintain a constant duct size. 3. Seal all joints with duct tape to prevent any leaks. 4. Do not use any type of flexible ducting. • Install a wall cap or roof cap at the exterior opening. Purchase the wall or roof cap and any transition and length of duct needed in advance. • When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions. Recirculation Install Planning This hood may be installed in recirculation mode and is shipped in this configuration. The charcoal filter is necessary for recirculation installation. This part may need to be ordered separately depending on model. Power Supply Planning The location of the power supply connection is called out in the Prepare for Electrical and Venting section on page 15. POWER SUPPLY IMPORTANT - (Please read carefully) WARNING FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow National Electrical Codes or prevailing local codes and ordinances. Electrical supply These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse. • Wiring must be 2 wire with ground. • If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding. • Route house wiring as close to the installation location as possible in the ceiling or wall. • Connect the wiring to the house wiring in accordance with local codes. Grounding instructions The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood. WARNING The improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded. 14 49-80783-3
![](/manual_guide/products/general-electric-pvx7360sjss-use-care-manual-ecb9904/14.png)