GE DMCD330GJWC Quick Specs - Page 2
Cu. Ft. Capacity Coin-Operated Gas Dryer
![]() |
View all GE DMCD330GJWC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
DMCD330GJ GE® 7.0 Cu. Ft. Capacity Coin-Operated Gas Dryer For complete information, see installation instructions packed with your dryer. Special Installation Requirements Ducting Materials: For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. If "all rigid metal" duct cannot be used, then "flexible all metal" venting can be used, but it will reduce the maximum recommended duct length. Exhaust Length Calculation: 1. D etermine the number of 90° turns needed for your installation. If you exhaust to the side or bottom of dryer, add one turn. 2. T he maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated is shown in the table. The maximum length for flexible ducts are less than for rigid duct. A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated as a 90° elbow. A turn over 45° should be treated as a 90° elbow. Exhausting the dryer to the outside is strongly recommended to prevent large amounts of moisture and lint from being blown into the room. Gas dryers or any dryer located in a closet must be exhausted to the outside. Alcove or Closet Installation: • If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back. • The dryer MUST be exhausted to the outside. • Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side; 3" front and rear • Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52". • Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed. • No other fuel-burning appliance shall be installed in the same closet with a gas dryer. Bathroom or Bedroom Installation: • The dryer GE Dryer Vent GE Dryer Vent MUST be exhausted to the outdoors. • The installation must conform with the local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223. Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down. Other terminations, such as louvered wall boxes, are acceptable provided they are equivalent to a 4" opening dampered wall cap. For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.626.2000. Minimum Clearances other than Alcove or Closet Installation: • Minimum clearances to combustible surfaces are: 0" both sides; 3" rear Dryer Exhausting Information: Use metal duct only, vertical and horizontal ducting. A A A4 4 B B Domestic 2-1/2 Dryer Models 2-1/2 7.3 Capacity Electric and Gas Dryers 7.0 and 6.0 Capacity Models all Electric Dryers 7.0 and 6.0 Capacity Models all Gas Dryers 5.7 Capacity Electric and Gas Dryers Number of 90° Turns 0 1 2 3 4 0 1 2 3 4 0 1 2 3 0 1 2 3 4 Best Performance Maximum Length of 4" Dia. Rigid Metal Duct Exhaust Hood Type B A 2 -1/2" 4" Opening Opening 150 ft. 140 ft. 130 ft. 120 ft. 110 ft. 90 ft. 60 ft. 45 ft. 35 ft. 25 ft. 90 ft. 60 ft. 45 ft. 35 ft. 60 ft. 52 ft. 44 ft. 32 ft. 28 ft. 127 ft. 117 ft. 107 ft. 97 ft. 87 ft. 60 ft. 45 ft. 35 ft. 25 ft. 15 ft. 60 ft. 45 ft. 35 ft. 25 ft. 48 ft. 40 ft. 32 ft. 24 ft. 16 ft. Maximum Length of 4" Dia. Flexible Metal Duct Exhaust Hood Type A 4" Opening B 2 -1/2" Opening 75 ft. 52 ft. 65 ft. 42 ft. 55 ft. 32 ft. 45 ft. 22 ft. 35 ft. 12 ft. 55 ft. 45 ft. 40 ft. 30 ft. 30 ft. 20 ft. 20 ft. 15 ft. 15 ft. 10 ft. 55 ft. 45 ft. 40 ft. 30 ft. 30 ft. 20 ft. 20 ft. 15 ft. 30 ft. 18 ft. 22 ft. 14 ft. 14 ft. 10 ft. - - - - Listed by Underwriters Laboratories Specification Revised 11/11 370426
![](/manual_guide/products/general-electric-dmcd330gjwc-quick-specs-58291f4/2.png)