PACKAGING & NORMAL SOUNDS 7 Explanation of symbols displayed on the unit This symbol shows that this appliance used a flammable WARNING refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire. This symbol shows that the operation manual should be read CAUTION carefully. CAUTION This symbol shows that a service personnel should be handling this equipment with reference to the installation manual. CAUTION This symbol shows that information is available such as the operating manual or installation manual. Normal Sounds 3 4 2 5 1 1 Gurgle/Hiss "Gurgling or hissing" noise may be heard due to refrigerant passing through evaporator during normal operation. 2 Sound of Rushing Air At the front of the unit, you may hear the sound of rushing air being moved by the fan. 3 High pitched Chatter Today's high e ciency compressors may have a high pitched chatter during the cooling cycle. 4 Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation. 5 Pinging or Swishing Droplets of water hitting condenser during normal operation may cause "pinging or swishing" sounds. Note: Don't try to drill any holes on the base pan to eliminate the normal sounds, otherwise it will void the warranty.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

1
2
3
4
5
7
PACKAGING & NORMAL SOUNDS
Explanation of symbols displayed on the unit
WARNING
This symbol shows that this appliance used a flammable
refrigerant. If the refrigerant is leaked and exposed to an
external ignition source, there is a risk of fire.
This symbol shows that the operation manual should be read
carefully.
This symbol shows that a service personnel should be
handling this equipment with reference to the installation
manual.
This symbol shows that information is available such as the
operating manual or installation manual.
CAUTION
CAUTION
CAUTION
Gurgle/Hiss
“Gurgling or hissing” noise may be
heard due to refrigerant passing
through evaporator during normal
operation.
1
Sound of Rushing Air
At the front of the unit, you may hear
the sound of rushing air being moved
by the fan.
2
High pitched Chatter
Today’s high efficiency compressors
may have a high pitched chatter during
the cooling cycle.
3
4
Vibration
Unit may vibrate and make noise
because of poor wall or window
construction or incorrect installation.
5
Pinging or Swishing
Droplets of water hitting condenser
during normal operation may cause
“pinging or swishing” sounds.
Note: Don’t try to drill any holes on the
base pan to eliminate the normal
sounds, otherwise it will void the
warranty.
Normal Sounds