Countertop Cutout Opening
UPC - 057112104263
View all Frigidaire FFGC3015LW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
GAS COOKTOP INSTALLATION INSTRUCTIONS 13" (33 cm) Max. Depth For Cabinet Installed Above Cooktop. A Min. 18" Min. (45.7cm Min.) Dimensions K is the Minimum Distance Required Between Rear of Cooktop and Adjacent Combustible Surfaces. Dimension J is the Minimum Clearance Required From Left Side of cooktop To Adjacent Combustible Surface. 24" (61 cm) 30" (76.2 cm) Min. Clearance Between the Top of the Cooking Platform and Unprotected Wood or Metal Cabinet 24" (61 cm) Min. when Bottom of Clearance Wood or Metal Cabinet is Protected by Not Less Than 1/8" Flame Retardant Millboard Covered with Not Less Than N0.28 MSG Sheet Steel, 0.015" (0.04 cm) Stainless Steel, 0.024" (0.06 cm) Aluminum or 0.020" (0.05 cm) Copper. Dimension L is the Minimum Clearance Required From Right Side of Cooktop To Adjacent Combustible Surface. Drawers Cannot Be Used With This Cooktop Since Burner Box Extends 3" (7.6 cm) Below Surface of Countertop. To eliminate the risk of burns or fire by reaching over heated surfaces, cabinet storage space located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets. MODEL 30" Models 36" Models J 6" (15.2 cm) 3" (7.6 cm) K 1¾" (3.8 cm) 3¾" (9.5 cm) L 4" (10.2 cm) 5" (12.7 cm) Figure 2 - COUNTERTOP CUTOUT OPENING 3