Connection to gas

Page 6 highlights

GAS COOKTOP INSTALLATION INSTRUCTIONS 4. Connection to gas A. 26" Cooktop (see figure 7) Cooktop Burner Box 90° Elbow Pressure Regulator Adaptor or Union Figure 7 Coupling Manifold Pipe ½" Nipple External Shut-off Valve Hookup the cooktop to the gas supply line. Install the pressure regulator with the arrow pointing toward cooktop and where you can reach the access cap. Be sure you know how and where to shut off the gas supply to the cooktop. Leak testing of the appliance shall be conducted according to the manufacturer's instructions. Check for leaks. After connecting cooktop gas, check system for leaks with a manometer. If a manometer is not available shut all pilots off, turn the gas supply on the unit and use a liquid leak detector at all joints and connections to check for leaks. Tighten all connections if necessary to prevent gas leakage in the cooktop or supply line. Check alignment of valves after connecting the cooktop to the gas supply to be sure the manifold pipe has not been moved. A misalignment could cause the valve knob stem to rub on the control panel, resulting in a gas leak at the valve. IMPORTANT: A pipe joint sealant resistant to the action of LP Gas must be used on all pipe connections. IMPORTANT: Remove all packing material and literature from cooktop before connecting gas and electrical supply to the appliance. B. 30" and 36" Cooktops (see figure 8) Cooktop Burner Box Pressure Regulator Manifold Pipe ½" Coupling (36" Cooktops Only) ½" Nipple Do not use flame to check for leaks from gas connections. Checking for leaks with a flame may result in a fire or explosion. Disconnect the cooktop and its individual shutoff valve from the gas supply piping system during any pressure test greater than ½ psig. Isolate the cooktop from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig. Adaptor or Union Figure 8 External Shut-off Valve 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

GAS COOKTOP INSTALLATION INSTRUCTIONS
6
4. Connection to gas
A. 26" Cooktop
(see figure 7)
Figure 7
Cooktop
90° Elbow
Coupling
Manifold Pipe
½" Nipple
Pressure Regulator
Adaptor or Union
External
Shut-off Valve
B. 30" and 36" Cooktops
(see figure 8)
Hookup the cooktop
to the gas supply line.
Install the pressure regulator
with the arrow pointing
toward cooktop and where you can reach the access
cap. Be sure you know how and where to shut off the
gas supply to the cooktop.
Leak testing
of the appliance shall be conducted
according to the manufacturer's instructions.
Check for leaks.
After connecting cooktop gas, check
system for leaks with a manometer. If a manometer is
not available shut all pilots off, turn the gas supply on
the unit
and use a liquid leak detector at all joints and
connections to check for leaks.
Tighten all connections
if necessary to prevent gas
leakage in the cooktop or supply line.
Check alignment of valves
after connecting the
cooktop to the gas supply to be sure the manifold pipe
has not been moved. A misalignment could cause the
valve knob stem to rub on the control panel, resulting in
a gas leak at the valve.
IMPORTANT
: A pipe joint sealant resistant to the action
of LP Gas must be used on all pipe connections.
IMPORTANT
: Remove all packing material and literature
from cooktop before connecting gas and electrical
supply to the appliance.
Do not use flame to check for leaks from
gas connections. Checking for leaks with a flame may
result in a fire or explosion.
Disconnect the cooktop and its individual shutoff
valve
from the gas supply piping system during any
pressure test greater than ½ psig.
Isolate the cooktop from the gas supply piping
system
by closing its individual manual shutoff valve
during any pressure testing of the gas supply piping
system at test pressures equal to or less than ½ psig.
External Shut-off
Valve
Burner
Box
Cooktop
Manifold Pipe
½" Nipple
Pressure
Regulator
Adaptor or Union
Figure 8
Burner
Box
½" Coupling