Fisher and Paykel RDV3-304-N Data Sheet Dual Fuel Range - Page 2

Front View, Profile View, Plan View

Page 2 highlights

C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE F CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL PLAN VIEW DATUM : TOP OF COUNTERTOP C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE E MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY D MINIMUM CLEARANCE: VENTILATION HOOD D MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFACE B MINIMUM CLEARANCE: ADJACENT OVERHEAD CABINET DATA SHEET 30" Professional Freestanding Range - Dual Fuel Model no: RDV3-304 (refer page 5 for metric measurements) Clearance Dimensions a Minimum width of ventilation hood installed above range - not shown* B Minimum vertical distance between countertop and cabinet extending above counter c Minimum clearance from left and right of range to nearest vertical combustible surface d Minimum clearance from cooking surface to: - combustible surface centered above the cooking surface - combustible covering for ventilation hood centered above the cooking surface - non-combustible surface** centered above the cooking surface e Maximum overall depth of overhead cabinetry f Distance from center of rear burner to rear of product in 30'' 18'' 12'' 54'' 36'' 30'' 13'' 8 5/8" *IMPORTANT NOTE: For full installation and clearance details please refer to our installation manual. **Non-combustible surfaces: as defined in 'National Fuel Gas Code' (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less than 6" (152mm) must be approved by the local codes and/or by the local authority having jurisdiction. DATUM : FLOOR FRONT VIEW 0 5 10 20 inches PROFILE VIEW CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL INDICATES CLEARANCES INDICATES PRODUCT DATUM DATE: 14.07.2020 IMPORTANT NOTE: Throughout this guide, dimensions may vary by ±2mm (1/16''). Please read the installation manual for detailed information on installing the product. For full installation instructions & specifications visit fisherpaykel.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

DATA SHEET
30" Professional Freestanding Range -
Dual Fuel
0
5
10
20
inches
INDICATES CLEARANCES
---------------
INDICATES PRODUCT DATUM
--------------------
DATE:
14.07.2020
IMPORTANT NOTE: Throughout this guide, dimensions may vary by
±
2mm (1/16'').
Please read the installation manual for detailed information on installing the
product. For full installation instructions & specifications visit fisherpaykel.com
Model no:
RDV±-±04
(refer page 5 for metric measurements)
Clearance Dimensions
in
a
Minimum width of ventilation hood installed above range
- not shown*
30''
B
Minimum vertical distance between countertop and cabinet
extending above counter
18''
c
Minimum clearance from left and right of range to nearest
vertical combustible surface
12''
d
Minimum clearance from cooking surface to:
- combustible surface centered above the cooking surface
- combustible covering for ventilation hood centered above
the cooking surface
- non-combustible surface** centered above the cooking
surface
54''
36''
30''
e
Maximum overall depth of overhead cabinetry
13''
f
Distance from center of rear burner to rear of product
8 5/8"
*IMPORTANT NOTE: For full installation and clearance details please refer to
our installation manual.
**Non-combustible surfaces: as defined in ‘National Fuel Gas Code’ (ANSI
Z22±.1, Current Edition). Clearances from non-combustible materials are not
part of the ANSI Z21.1 scope and are not certified by UL. Clearances of less
than 6" (152mm) must be approved by the local codes and/or by the local
authority having jurisdiction.
DATUM : FLOOR
FRONT VIEW
PROFILE VIEW
DATUM :
TOP OF COUNTERTOP
CABINET FACE FOR INSTALLATION
WITH PROJECTING CONTROL PANEL
CABINET FACE FOR INSTALLATION
WITH FLUSH CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
PROJECTING CONTROL PANEL
CABINET FACE FOR
INSTALLATION WITH
FLUSH CONTROL PANEL
PLAN VIEW
MINIMUM CLEARANCE:
COMBUSTIBLE SURFACE
MAXIMUM OVERALL DEPTH
OF OVERHEAD CABINETRY
MINIMUM CLEARANCE:
ADJACENT OVERHEAD CABINET
MINIMUM CLEARANCE:
NON-COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
VENTILATION HOOD
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
MINIMUM CLEARANCE:
NEAREST VERTICAL
COMBUSTIBLE SURFACE
D
E
D
D
B
C
C
F