Dell Brocade 5100 Fabric OS v7.0.2 Release Notes v1.0 - Page 57

Defect ID, Technical Severity, Summary, Symptom, Feature, Function, Probability, Found in Release,

Page 57 highlights

Close with Code Change in Fabric OS v7.0.2 Defect ID: DEFECT000399130 Technical Severity: Medium Summary: Customer has experienced a large number of C2-5825 CRC with Good EOF Errors with FC864 in slot 1 of DCX Symptom: Customer is experiencing a large number of CRC with good EOF errors on DCX system when an FC8-64 is installed in slot 1. Feature: 8G ASIC Driver Function: C2 ASIC driver Probability: Low Found in Release: FOS6.4.2 Service Request ID: 721423 Defect ID: DEFECT000399592 Technical Severity: Medium Summary: BR6505 switch LED behavior of FAN FRU does not match the hardware manual. Symptom: When a FAN is stopped(or detected as faulty by FOS), the LED should flash green but BR6505 shows No light Feature: Field Escalation Function: Fabric Services Probability: High Found in Release: FOS7.0.1 Service Request ID: 724111 Defect ID: DEFECT000399874 Technical Severity: Medium Summary: FOS 7.0.1 isn't getting FR4-18i portshow fciptunnel output in supportsave Symptom: Supoportsave does not contain portshow fciptunnel output for FR4-18i Feature: FCIP Function: Other Probability: High Found in Release: FOS7.0.1 Service Request ID: 725315 Defect ID: DEFECT000399885 Technical Severity: Medium Summary: weblinker file descriptor on CEE platform leaks when monitored by BNA Symptom: Customer will experience asserts and weblinker terminations & restarts. This is non disruptive to customer traffic. Feature: Field Escalation Function: FCoE Probability: High Found in Release: FOS7.0.1 Service Request ID: 719205 Defect ID: DEFECT000342830 Technical Severity: Low Summary: ceeportloopbacktest "-port" option does not run correctly on 8000 Symptom: BR8000 did not test the CEE port which user selected with "-port" option. Feature: Diagnostics Function: Other Probability: High Found in Release: FOS6.4.1 Service Request ID: 577081 Fabric OS v7.0.2 Release Notes v1.0 Page 57 of 99

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

Close with Code Change in Fabric OS v7.0.2
Fabric OS v7.0.2 Release Notes v1.0
Page 57 of 99
Defect ID:
DEFECT000399130
Technical Severity:
Medium
Summary:
Customer has experienced a large number of C2-5825 CRC with Good EOF Errors with FC8-
64 in slot 1 of DCX
Symptom:
Customer is experiencing a large number of CRC with good EOF errors on DCX system when
an FC8-64 is installed in slot 1.
Feature:
8G ASIC Driver
Function:
C2 ASIC driver
Probability:
Low
Found in Release:
FOS6.4.2
Service Request ID:
721423
Defect ID:
DEFECT000399592
Technical Severity:
Medium
Summary:
BR6505 switch LED behavior of FAN FRU does not match the hardware manual.
Symptom:
When a FAN is stopped(or detected as faulty by FOS), the LED should flash green but
BR6505 shows No light
Feature:
Field Escalation
Function:
Fabric Services
Probability:
High
Found in Release:
FOS7.0.1
Service Request ID:
724111
Defect ID:
DEFECT000399874
Technical Severity:
Medium
Summary:
FOS 7.0.1 isn't getting FR4-18i portshow fciptunnel output in supportsave
Symptom:
Supoportsave does not contain portshow fciptunnel output for FR4-18i
Feature:
FCIP
Function:
Other
Probability:
High
Found in Release:
FOS7.0.1
Service Request ID:
725315
Defect ID:
DEFECT000399885
Technical Severity:
Medium
Summary:
weblinker file descriptor on CEE platform leaks when monitored by BNA
Symptom:
Customer will experience asserts and weblinker terminations & restarts.
This is non
disruptive to customer traffic.
Feature:
Field Escalation
Function:
FCoE
Probability:
High
Found in Release:
FOS7.0.1
Service Request ID:
719205
Defect ID:
DEFECT000342830
Technical Severity:
Low
Summary:
ceeportloopbacktest "-port" option does not run correctly on 8000
Symptom:
BR8000 did not test the CEE port which user selected with “-port” option.
Feature:
Diagnostics
Function:
Other
Probability:
High
Found in Release:
FOS6.4.1
Service Request ID:
577081