Dacor RNR30N Installation Instruction - Renaissance 30" Electric Inductio - Page 15
Wire Conduit-Junction Box, Connection with External Ground, Wire Conduit-Junction Box Connection
![]() |
View all Dacor RNR30N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Installation Instructions Connection to house power supply Junction box Separate No. 10 (minimum) copper grounding wire Connection to house power supply Wire nut 3 places Junction box RED RED GREEN GREEN WHITE WHITE BLACK BLACK Fasten clamp tightly on pipe Wire nut 4 places Conduit to appliance 3-Wire Conduit-Junction Box Connection Conduit to appliance 3-Wire Conduit-Junction Box Connection with External Ground 13
![](/manual_guide/products/dacor-rnr30n-installation-instruction-renaissance-30-electric-induction-range-eb45dae/15.png)
13
Installation Instructions
RED
RED
GREEN
WHITE
WHITE
BLACK
BLACK
GREEN
Fasten clamp
tightly on pipe
3-Wire Conduit-Junction Box
Connection with External Ground
Separate No. 10 (minimum)
copper grounding wire
Wire nut
4 places
Conduit to
appliance
Conduit to
appliance
Wire nut
3 places
Junction box
Junction box
3-Wire Conduit-Junction Box Connection
Connection to house
power supply
Connection to house
power supply