Cobra Cobra JumPack Cobra JumPack - Page 1

Cobra Cobra JumPack Manual

Page 1 highlights

CPP 7500 User Manual Portable Power - Anytime, Anywhere! Thank for purchasing the Cobra CPP 7500 JumPack™ jump starter portable PowerPack. Before using this product, please read these instructions carefully to learn about the features and capabilities of the JumPack and how you can get the best out of it. Note: Please charge your CPP 7500 JumPack completely prior to using it for the rst time. ©2014 Cobra Electronics Corp. Part No. 480-936-P Printed in China Version B IMPORTANT SAFETY INSTRUCTIONS Charge the JumPack fully prior to use. WARNING: Keep the unit clear of re and water. WARNING: Shock Hazard. Keep away from children. Do not insert foreign objects into the jumper cables port/jack, the USB output port, or the DC input jack. Do not expose this product to water, rain, snow, condensation, or spray. Do not open the JumPack to replace the internal battery. No user replaceable parts are inside the JumPack. WARNING: Explosion Hazard. Do not use this product where there are ammable fumes or gases, such as in the bilge of a gasoline-powered boat, or near propane tanks. Do not use this product in an enclosure containing automotive-type lead-acid batteries. The jump start cable clamps must be connected positive to positive (red clip to battery (+)) and negative to negative (black clip to battery (-)). A reverse polarity connection (positive to negative) may cause damage to the JumPack and/or create a sparking/explosion hazard. WARNING: Fire Hazard Do not crush or puncture the JumPack. Never allow the jump start cables' red and black clamps' metal contacts to touch each other or another common metal conductor. This could cause damage to the unit and/or create a re hazard. Always disconnect the jump start cables from the JumPack after each use and store separately. The jump start feature is designed for short term operation only. Turn the ignition key for no more than 3 seconds at a time. Operating the jump start feature for more than 3 seconds may cause damage to the unit. Allow the JumPack to cool down for at least 1 minute after each jump start attempt. .1. Caution: Operating temperature Do not expose the JumPack to temperatures over +113° F (+45° C) or under -14° F (-10° C). Using the JumPack at high or low temperatures may reduce the internal battery capacity and shorten the battery life. Note: In extreme cold weather conditions, please bring the JumPack indoors for best results. Precautions when working with batteries WARNING: Explosion and re hazard 1. Follow all instructions published by the battery manufacturer and the manufacturer of the equipment in which the battery is installed. 2. Make sure the area around the battery is well-ventilated. 3. Never smoke or allow a spark or ame in the vicinity of the engine or batteries. 4. Be careful not to drop a metal object on the battery or allow a metal tool to simultaneously touch the positive and negative cable ends or battery terminals. 5. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with batteries. Batteries produce a short-circuit current high enough to weld a ring or other similar objects to metal, causing a severe burn. 6. If you need to remove a battery, always remove the negative terminal from the battery rst. Make sure all accessories are off so you don't cause an arc. 7. Someone should be within range of your voice, or close enough to come to your aid when you work near batteries. 8. Have plenty of fresh water, soap and a supply of baking soda on hand in the area of the batteries in case of contact with battery acid. Baking soda neutralizes lead acid battery electrolyte. 9. The JumPack is supplied with a rechargeable Li-Cobalt battery. This battery is self-contained and not consumer replaceable. Battery must be disposed of properly when it no longer holds a charge. Proper charging practices will increase the life of the batteries.For information on battery recycling call toll free 800-822-8837. .2. Product: Battery Status Indicator LEDs Jumper cable with clamps Power/Flashlight/Battery Capacity Button LED Flashlight/Strobe Light/ S.O.S Light USB 5V/2.1 Amp Output Jump Starter Cable Input 12V DC Charge Input Home adaptor Car adaptor Operation: Recharging the JumPack: The CPP 7500 JumPack can be recharged with the supplied 120V AC wall charger connected to an AC home outlet or with the supplied 13.8V DC vehicle charger. When the CPP 7500 is charging; the LEDs will show the current battery life. The last LED that is lit will blink to show that the JumPack is charging. When the JumPack is fully charged the LEDs will turn off automatically. For best battery performance the JumPack should be fully recharged every 3 months. .3. Check Battery Capacity: To check the battery capacity of the JumPack press the Power/Flashlight button on the top of the unit with no device connected. The blue LEDs will show the remaining battery capacity: Battery Status Indicator LEDs 1 LED on: 10%-40% charge 2 LEDs on: 40%-65% charge 3 LEDs on: 65%-85% charge 4 LEDs on: 85%-100% charge Note: When charging a device the number of lit LEDs may decrease while the JumPack is in use. The battery capacity indicator cannot accurately measure the capacity during rapid charging. To con rm the real battery capacity, disconnect the device being charged and press the power/ ashlight/capacity button. .4.

  • 1
  • 2

CPP 7500
User Manual
Portable Power - Anytime, Anywhere!
Thank for purchasing the Cobra CPP 7500 JumPack
jump
starter portable PowerPack. Before using this product, please
read these instructions carefully to learn about the features
and capabilities of the JumPack and how you can get the
best out of it.
Note:
Please charge your CPP 7500 JumPack completely
prior to using it for the first time.
©2014 Cobra Electronics Corp.
Part No. 480-936-P
Printed in China
Version B
Charge the JumPack fully prior to use.
WARNING:
Keep the unit clear of fire and water.
WARNING: Shock Hazard.
Keep away from children. Do not
insert foreign objects into the jumper cables port/jack, the USB
output port, or the DC input jack. Do not expose this product to
water, rain, snow, condensation, or spray. Do not open the
JumPack to replace the internal battery. No user replaceable
parts are inside the JumPack.
WARNING: Explosion Hazard.
Do not use this product where
there are flammable fumes or gases, such as in the bilge of a
gasoline-powered boat, or near propane tanks. Do not use this
product in an enclosure containing automotive-type lead-acid
batteries.
The jump start cable clamps must be connected positive to
positive (red clip to battery
(+)) and negative to negative (black
clip to battery (-)).
A reverse polarity connection (positive to
negative) may cause damage to the JumPack and/or create a
sparking/explosion hazard.
WARNING: Fire Hazard
Do not crush or puncture the JumPack. Never allow the jump start
cables’ red and black clamps’ metal contacts to touch each other or
another common metal conductor.
This could cause damage to the
unit and/or create a
fire hazard. Always disconnect the jump start
cables from the JumPack after each use and store separately. The
jump start feature is designed for short term operation only.
Turn the ignition key for
no more than
3 seconds
at a time.
Operating the jump start feature for more than
3 seconds
may
cause damage to the unit.
Allow the JumPack to cool down for at
least
1 minute
after each jump start attempt.
IMPORTANT SAFETY INSTRUCTIONS
Caution: Operating temperature
Do not expose the JumPack to temperatures over +113° F (+45° C) or
under -14° F (-10° C).
Using the JumPack at high or low temperatures
may reduce the internal battery capacity and shorten the battery life.
Note:
In extreme cold weather conditions, please bring the JumPack
indoors for best results.
Precautions when working with batteries
WARNING: Explosion and fire hazard
1.
Follow all instructions published by the battery manufacturer and the
manufacturer of the equipment in which the battery is installed.
2.
Make sure the area around the battery is well-ventilated.
3.
Never smoke or allow a spark or flame in the vicinity of the engine
or batteries.
4.
Be careful not to drop a metal object on the battery or allow a
metal tool to simultaneously touch the positive and negative cable
ends or battery terminals.
5.
Remove personal metal items such as rings, bracelets, necklaces,
and watches when working with batteries. Batteries produce a
short-circuit current high enough to weld a ring or other similar
objects to metal, causing a severe burn.
6
.
If you need to remove a battery, always remove the negative
terminal from the battery first. Make sure all accessories are
off so you don’t cause an arc.
7.
Someone should be within range of your voice, or close enough to
come to your aid when you work near batteries.
8.
Have plenty of fresh water, soap and a supply of baking soda on
hand in the area of the batteries in case of contact with battery acid.
Baking soda neutralizes lead acid battery electrolyte.
9.
The JumPack is supplied with a rechargeable Li-Cobalt battery.
This battery is self-contained and not consumer replaceable. Battery
must be disposed of properly when it no longer holds a charge. Proper
charging practices will increase the life of the batteries.
For information
on battery recycling call toll free 800-822-8837.
Product:
Jumper cable with clamps
Battery Status Indicator LEDs
Jump Starter Cable Input
12V DC Charge Input
USB 5V/2.1 Amp Output
LED Flashlight/Strobe
Light/ S.O.S Light
Power/Flashlight/Battery
Capacity Button
Home adaptor
Car adaptor
Recharging the JumPack:
The CPP 7500 JumPack can be recharged with the supplied 120V AC
wall charger connected to an AC home outlet or with the supplied 13.8V
DC vehicle charger.
When the CPP 7500 is charging; the LEDs will show the current battery
life. The last LED that is lit will blink to show that the JumPack is charging.
When the JumPack is fully charged the LEDs will turn off automatically.
For best battery performance the JumPack should be fully recharged
every 3 months.
Operation:
Check Battery Capacity:
To check the battery capacity of the JumPack press the
Power/Flashlight button on the top of the unit with no device
connected. The blue LEDs will show the remaining battery capacity:
1
LED on: 10%-40% charge
2
LEDs on: 40%-65% charge
3
LEDs on: 65%-85% charge
4
LEDs on: 85%-100% charge
Note:
When charging a device the number of lit LEDs may
decrease while the JumPack is in use. The battery capacity
indicator cannot accurately measure the capacity during rapid
charging. To confirm the real battery capacity, disconnect the
device being charged and press the power/flashlight/capacity button.
Battery Status Indicator LEDs
.1.
.2.
.3.
.4.