P-touch Template 2.0 Command Reference ESC iXy1 Retrieve cut options (specifying number of labels) ASCII: ESC i X y 1 n1 n2 Decimal: 27 105 88 121 49 nd1 nd2 Hexadecimal: 1B 69 58 79 31 nh1 nh2 Parameters nh1: 00h (Fixed) nh2: 00h (Fixed) Description Retrieves the setting for cutting after a specified number of labels. 3-byte data is returned from the printer. [1]: 01h (Fixed) [2]: 00h (Fixed) [3]: Setting The retrieved value is a value specified by a static command. This command is applied to only a printer with auto cutter. Example When cutting is specified for every five labels: Code: ESC i X y 1 00h 00h (1Bh 69h 58h 79h 31h 00h 00h) Returned value: 01h 00h 05h - 95 - 7. Control Command Details
P-touch Template 2.0 Command Reference
- 95 -
7. Control Command Details
ESC iXy1
Retrieve cut options (specifying number of labels)
ASCII:
ESC i
X
y
1
n1
n2
Decimal:
27
105 88
121 49 nd1 nd2
Hexadecimal: 1B
69
58
79
31 nh1 nh2
Parameters
nh1: 00h (Fixed)
nh2: 00h (Fixed)
Description
Retrieves the setting for cutting after a specified number of labels.
3-byte data is returned from the printer.
[1]: 01h (Fixed)
[2]: 00h (Fixed)
[3]: Setting
The retrieved value is a value specified by a static command.
This command is applied to only a printer with auto cutter.
Example
When cutting is specified for every five labels:
Code: ESC i X y 1 00h 00h
(1Bh 69h 58h 79h 31h 00h 00h)
Returned value: 01h 00h 05h