Brother International BAS-511 Instruction Manual - English - Page 49

Error

Page 49 highlights

4. OPERATIONS 4-19. Error code list 4-19. Error code list • If an error message is displayed during sewing, refer to the table below for the necessary remedy. Error code El E2 E3 E4 E5 E6 E7 E8 E9 E10 E11 E12 E13 E14 El6 E17 Details of error Start switch is on when power is turned on. Remedy Turn power off Foot switch is on when power is turned on. Turn power off EMERGENCY switch is on when power is turned on. Turn power off Feed motor problem (communication error with motor circuit board) Turn power off Incorrect cutter or gauge size setting Turn power off Stop sensor does not turn on when not sewing. (sensor malfunction, incorrect adjustment or handle was turned) Distance A in program is smaller than minimum distance A allowed by panel DIP switch setting. Cutter sensor does not turn on. (sensor malfunction, incorrect adjustment or cutter has dropped) Pneumatic feed does not finish within allotted time. (mechanical contact, fuse F3 on power supply circuit board is blown, or feed motor or printed circuit board malfunction) Turn power off RESET switch Turn power off Turn power off Corrupt program data Turn power off Distance A + distance D + correction value in program is larger than maximum feed amount allowed by panel DIP switch setting. Servo sensor error (Either servo sensor is not on when power is turned on, or both sensors are off during sewing.) Machine error when sewing completed. (overrun error, upper clamping foot malfunction, etc.) Upper clamping foot operation problem (Upper clamping foot operation problem, upper clamping foot sensor switch malfunction or no air) Machine does not start. (Stop signal does not turn off even when machine is turned on.) Sewing does not stop. top signal does not switch on 7 seconds after sewing starts.) Table feed or ladies' garment sewing and long garment sewing are set simultaneously. RESET switch RESET switch Turn power off RESET switch Turn power off Turn power off Turn power off Turn power off (NOTE) If the error code is flashing, the error cannot be reset unless the power is turned off. If the error code is illuminated, remove the cause of the error, and then press the RESET switch.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

4.
OPERATIONS
4-19.
Error
code
list
4-19.
Error
code
list
If
an
error
message
is
displayed
during
sewing,
refer
to
the
table
below
for
the
necessary
remedy.
Error
code
Details
of
error
Remedy
El
Start
switch
is
on
when
power
is
turned
on.
Turn
power
off
E2
Foot
switch
is
on
when
power
is
turned
on.
Turn
power
off
E3
EMERGENCY
switch
is
on
when
power
is
turned
on.
Turn
power
off
E4
Feed
motor
problem
(communication
error
with
motor
circuit
board)
Turn
power
off
E5
Incorrect
cutter
or
gauge
size
setting
Turn
power
off
E6
Stop
sensor
does
not
turn
on
when
not
sewing.
(sensor
malfunction,
incorrect
adjustment
or
handle
was
turned)
Turn
power
off
E7
Distance
A
in
program
is
smaller
than
minimum
distance
A
allowed
by
panel
DIP
switch
setting.
RESET
switch
E8
Cutter
sensor
does
not
turn
on.
(sensor
malfunction,
incorrect
adjustment
or
cutter
has
dropped)
Turn
power
off
E9
Pneumatic
feed
does
not
finish
within
allotted
time.
(mechanical
contact,
fuse
F3
on
power
supply
circuit
board
is
blown,
or
feed
motor
or
printed
circuit
board
malfunction)
Turn
power
off
E10
Corrupt
program
data
Turn
power
off
E11
Distance
A
+
distance
D
+
correction
value
in
program
is
larger
than
maximum
feed
amount
allowed
by
panel
DIP
switch
setting.
RESET
switch
E12
Servo
sensor
error
(Either
servo
sensor
is
not
on
when
power
is
turned
on,
or
both
sensors
are
off
during
sewing.)
RESET
switch
Turn
power
off
E13
Machine
error
when
sewing
completed.
(overrun
error,
upper
clamping
foot
malfunction,
etc.)
RESET
switch
E14
Upper
clamping
foot
operation
problem
(Upper
clamping
foot
operation
problem,
upper
clamping
foot
sensor
switch
malfunction
or
no
air)
Turn
power
off
Machine
does
not
start.
(Stop
signal
does
not
turn
off
even
when
machine
is
turned
on.)
Turn
power
off
El6
Sewing
does
not
stop.
top
signal
does
not
switch
on
7
seconds
after
sewing
starts.)
Turn
power
off
E17
Table
feed
or
ladies'
garment
sewing
and
long
garment
sewing
are
set
simultaneously.
Turn
power
off
(NOTE)
If
the
error
code
is
flashing,
the
error
cannot
be
reset
unless
the
power
is
turned
off.
If
the
error
code
is
illuminated,
remove
the
cause
of
the
error,
and
then
press
the
RESET
switch.