BenQ PH460 Color Management Manual - Page 14
The Color Management is transmitting the updated Look Up Table LUT
View all BenQ PH460 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
14 Using the Color Management 3. The calibration window appears. Click Run to proceed. You can also click Track to measure the CIE1931 (x,y) values of current W,R,G and B colors at level 255 for further analysis. 4. You will be requested to put the color meter in the center of the display's screen. A center pattern is displayed on the screen for alignment at the same time. Click Yes. 5. The calibration starts, and the status will be indicated in the Calibration Status area. - Initial: The computer is validating connection to the display and color meter. - Measure: The color meter is measuring the display's color profile. - Produce: The Color Management is calculating for optimal values. - Write: The Color Management is transmitting the updated Look Up Table (LUT) to the display. - Fine-tune: The Color Management is fine-tuning the backlight. During calibration, do not change the position of the color meter, move the display to another location or change display settings. Otherwise the precision of calibration will be affected. 6. A dialog requesting you to move the color meter to the next display (current display ID + 1) appears. Repeat step 4 and step 5 to complete calibration for all displays.