Behringer UB-Xa User Manual - Page 15
USB Control, DIN Control, MPE Pitch Lowe, MPE Pitch Upper, MPE Profile, Shift & 66 - Velocity &
View all Behringer UB-Xa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
15 UB-Xa User Manual c - DIN Clock - switches transmission of internal clock over DIN MIDI OUT (on (default) or off using +/- buttons). d - USB Rt - switches sending of System Real Time data (start/stop/ pause/continue) from UB-Xa to USB MIDI OUT (on (default) or off using +/buttons). e - USB Clock - switches transmission of internal clock over USB (on (default) or off using +/- buttons). f - Program Change Rx - switches reception of program and bank change messages over either DIN or USB (on or off (default) using +/- buttons). g - Program Change Tx - switches transmission on program and bank change messages over either DIN or USB (on or off (default) using +/buttons). h - Surface NRPN - switches transmission of NRPN messages when controls are adjusted on or off (default). When NRPN is off MIDI CCs will be transmitted. Note that when the UB-Xa is acting as synchronization master for other MIDI equipment a short press of the play/pause or stop buttons will only enable or disable the UB-Xa's own sequencer. To control the external equipment as well use a double press or a long press. 10. USB Control - selects how the UB-Xa responds to, and transmits, MIDI messages over USB a - NRPN Tx - switches transmission of Non-Registered Parameter Numbers over USB for coarse and fine adjustment of parameters where allowed (on or off (default) using +/- buttons). b - NRPN Rx - switches reception of Non-Registered Parameter Numbers over USB for coarse and fine adjustment of parameters where allows (on (default) or off using +/- buttons). c - CC Tx - switches transmission of continuous controller data over USB (on (default) or off using +/- buttons). d - CC Rx - switches reception of continuous controller data over USB (on (default) or off using +/- buttons). 11. DIN Control - selects how the UB-Xa responds to, and transmits, MIDI messages over DIN a - NRPN Tx - switches transmission of Non-Registered Parameter Numbers over DIN for coarse and fine adjustment of parameters where allowed (on or off (default) using +/- buttons. b - NRPN Rx - switches reception of Non-Registered Parameter Numbers over DIN for coarse and fine adjustment of parameters where allow (on (default) or off using +/- buttons). c - CC Tx - switches transmission of continuous controller data over DIN (on (default) or off using +/- buttons). d - CC Rx - switches reception of continuous controller data over DIN (on (default) or off using +/- buttons). 12. MPE Pitch Lower - controls the sensitivity of MPE control of pitch bend for the lower keyboard, from 0 to 96. Default is 48. 13. MPE Pitch Upper - controls the sensitivity of MPE control of pitch bend for the upper keyboard, from 0 to 96. Default is 48. 14. MPE Profile - selects the MPE profile. Single allocates fifteen channels of MPE control to the spread of the keyboard, with channel 1 as the base channel; or Zones which allocates 7 channels each to upper and lower keyboards, with channel 1 as the lower base channel and channel 16 as the upper. MPE can also be disabled in this option. Default is Disabled. Note that the MIDI Rx channels selected in options 1 & 2 are disabled when in MPE mode. Please see the MPE chapter later in the manual for a full explanation of how MPE works, and specifically how it works with the UB-Xa. Shift & 66 - Velocity & Aftertouch 1. Porta Modes - allows selection of different portamento types: a - Match - matches the portamento speed of each note so that they arrive at their destination simultaneously (on or off (default) using +/- buttons). b - Quantize -switches between a standard smooth portamento curve and one where notes glissade through semitones between notes (on or off (default) using +/- buttons). c - Bend - switches between a standard portamento and one where there is always a bend from highest to lowest note when playing the same chord repeatedly (on or off (default) using +/- buttons). d - Exponential - all voices will take the same length of time to reach their new note (on or off (default) using +/- buttons). 2. Unison Priority - switches between Below (default), Above and Last note priority when in Unison mode. 3. Chord Priority - switches between Below (default), Above and Last note priority when in Chord mode. 4. Aftertouch Out - switches between Channel Pressure and Polyphonic Aftertouch (default) on MIDI OUTs. 5. AT Curve - sets intensity of Aftertouch Curve. Options are Soft, Medium (default) and Hard. 6. Aftertouch Flt - sets the amount of aftertouch affecting the filter from 0 (no affect) to 127 (full affect). Default is 63 7. Vel Curve - sets the intensity of the Velocity Curve. Options are Soft, Medium (default) and Hard. 8. Vel Scale - sets the velocity response level from 0 (minimum) to 127 (maximum). Default is 63. Shift & 67 - Voice Menu Atrophy - allows alteration of Atrophy settings for the current profile. 1. 2pole Floor - adjusts the minimum point of the Filter Frequency control (32) when the filter is in 2-pole mode; from 8.18 Hz to 130.81 Hz. 2. 4pole Floor - adjusts the minimum point of the Filter Frequency control (32) when the filter is in 4-pole mode; from 8.18 Hz to 130.81 Hz. 3. FltrFreq Amount - adjusts the sensitivity of the Filter Frequency control (32) from 48 semitones to 111 semitones. 4. FEnv Freq Amt - adjusts the range of the Filter Modulation control (34) from 48 semitones to 175 semitones. Default is 120 in all profiles. 5. ltrLFO Depth - adjusts the range of the LFO's filter modulation when selected by button 18 and Depth control (15); from 48 semitones to 175 semitones. 6. Res 2pCV Cap - caps the maximum level of the Resonance control (33) when the filter is in 2-pole mode; from 50.20 % to 100.00 %. At settings below 97.00 % the filter will not self-oscillate. 7. Res 4pCV Cap - caps the maximum level of the Resonance control (33) when the filter is in 4-pole mode; from 0.00 % to 100.00 %. At settings below 48.00 % the filter will not self-oscillate. 8. Filter Drift - adds a random voltage to the filter frequency cutoff. Ranges from 0.00 cent to 400.00 cent with the effect becoming more pronounced at higher settings. Default is 0.00 cent in all profiles.