Output Log
View all 3M WX36 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
6 Output Log In order to enable logging status data, please enable log setting through [File] [Log]. It does not record log data when it is unchecked. Output folder : (PJman installed folder)\Log\ Filename : TCP / IP network --- (IP address)_(Port No.).log (ex: 192.168.1.10_23.log) Serial (RS232C) --- COMM_(Port No.).log (ex: COMM_1.log) Format : Command log [Cmd ], [Date], [Action code], [Operation ID], [Operation Name], [Setting Value], [Result], [Return Value] Status log (only status is changed) [Stat], [Date], [Status Name], [Status] Example [Stat], 2008/11/07 20:06:16, Power Status, ON [Stat], 2008/11/07 20:06:16, Lamp Time, 0 [Stat], 2008/11/07 20:06:16, Filter Time, 0 [Stat], 2008/11/07 21:06:16, Lamp Time, 1 [Stat], 2008/11/07 21:06:16, Filter Time, 1 [Cmd ], 2008/11/07 21:10:35, Set, 0x2000, Input Source, 1, OK, 0 [Cmd ], 2008/11/07 21:15:27, Get, 0x6000, Power, 0, OK, 0 [Cmd ], 2008/11/07 21:15:27, Set, 0x6000, Power, 0, OK, 0 [Stat], 2008/11/07 21:15:30, Error Status, Disconnect © 3M 2012. All Rights Reserved. 84