    IP PBX phone service has been ordered and configured for your location. For more information about installation options and phone setup, see the VCS754 User's manual and the VCS754 Administrator and Provisioning Manual, available at businessphones.vtech.com. • When the base unit is powered up, the
  • Vtech VCS754 | Quick Start Guide - Rev 3 - Page 2
    VCS754 Administrator and Provisioning Guide. • Consult your service provider if you require additional user accounts or if you suspect a service on the wireless mic. Operating range This conference phone operates with the maximum power allowed by the Federal Communications Commission (FCC
  • 1
  • 2

The ErisStation SIP Conference Phone with Four Wireless Mics
requires connection to AC power to operate.
The supplied power adapter is designed for use with only the
ErisStation SIP Conference Phone with Four Wireless Mics. It is
not PoE compatible and is not designed to power any network
devices. Do not connect the supplied power adapter to any other
network devices through the supplied DC power cable or any
other Cat5e ethernet cable.
The ErisStation SIP Conference Phone with Four Wireless
Mics requires a network connection to an IP PBX to operate.
This quick start guide assumes that your network infrastructure
is established and that your IP PBX phone service has been
ordered and configured for your location. For more information
about installation options and phone setup, see the VCS754
User’s manual and the VCS754 Administrator and Provisioning
Manual, available at
businessphones.vtech.com
.
When the base unit is powered up, the status indicators turn
green for about two seconds.
The AC power cord is intended for a vertical or floor mount
position. The prongs are not designed to hold the plug in place if it
is plugged into a ceiling or cabinet outlet.
Install the wireless mic battery
Status indicators overview
Status indicators on the base unit
Power up
Green for about two seconds.
On a call
Green during a call.
Red when the system is muted during a call.
Incoming call
Flashes green when there is an incoming call.
Status indicator on the wireless mic
Power up
Orange for about two seconds.
On the cradle
Orange when charging in the cradle except
during registration.
Flash red and green alternately when the
non-registered wireless mic is charging on
the cradle.
Off the cradle
Green during a call.
Red when the system is muted during a call.
Off when the wireless mic is in idle mode or
without a battery.
Flashes orange when the wireless mic’s battery
is low.
Flashes green when there is an incoming call.
Flashes red slowly when the wireless mic is:
out of range; or
not registered; or
off cradle during paging (with a paging tone).
During
registration
Flashes red and green alternately.
Introduction
This quick start guide provides you with the basic installation,
setup, and operation instructions. A limited set of features are
described in abbreviated form.
You may refer to the user’s manual for complete installation
and operation instructions for this innovative and feature-rich
VTech product.
Parts checklist
Your VCS754 SIP Conference Phone with Four Wireless Mics
package contains the following items. Save your sales receipt and
original packaging in the event warranty service is necessary.
Connect base unit
Quick Start Guide
Model: VCS754
Wireless Conference System
ErisStation
businessphones.vtech.com
SIP Conference Phone with Four Wireless Mics
ErisStation
®
is a registered trademark of VTech Communications, Inc.
Orbitlink Wireless Technology
TM
is a trademark of VTech Communications, Inc.
User’s manual
Model: VCS754
businessphones.vtech.com
SIP Conference Phone with Four Wireless Mics
Quick Start Guide
Model: VCS754
Battery ×4
User’s manual
Wireless mic ×4
Base unit
DC power cable
Ethernet cable
AC power cord
Power adapter
Battery door ×4
USB cable
VCS754
ETHERNT CABLE
Quick start guide
To purchase any accessories or replacements, visit our website at
businessphones.vtech.com
or call
1-888-370-2006
.
1.
Plug one end of the DC power cable into the power jack of
the base unit, and plug the other end into the
VCS754
jack
of the power adapter. Route the cord through the slots.
2.
Plug one end of the Ethernet cable into the
LAN
jack of the
power adapter, and plug the other end into a network switch
or router.
3.
Plug the small end of the AC power cord into the power jack
of the adapter, and plug the large end into a wall outlet not
controlled by a switch.
4.
Optional: Plug the mini-USB end of the USB cable to the
base unit. Connect the other end of the USB cable to a PC
(to use PC speakerphone mode).
1.
Plug the battery connector securely into the socket inside
the battery compartment. Insert the battery (with the label
THIS SIDE UP
facing up) into the battery compartment.
2.
Slide the battery door until it clicks into place.
3.
Place the wireless mics into the charging cradles until they
are flush.
The status indicator on the wireless mic turns orange when charging,
and turns off when the wireless mic is fully charged.
Connect the base unit as shown below.
1
LAN
VCS754
2
3
E
Wall outlet
DC power cable
Ethernet cable
AC power cord
Slots
Network switch
or router
4
businessphones.vtech.com
®