Sub-Zero BI-36S Built-In Installation Guide

Sub-Zero BI-36S Manual

Sub-Zero BI-36S manual content summary:

  • Sub-Zero BI-36S | Built-In Installation Guide - Page 1
    INSTALLATION GUIDE Built-In Refrigeration
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 2
    Sub-Zero equipment, please take note of the following types of highlighted information throughout this guide: IMPORTANT NOTE highlights information that is especially relevant to a problem-free installation. CAUTION signals a situation where minor injury or product damage may occur if instructions
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 3
    Built-In Refrigeration 3 subzero.com/specs Sub-Zero Built-In Refrigeration The importance of the installation of the Sub-Zero built-in unit cannot be overemphasized. Installation should be done by a qualified installer. Before you begin the installation process, it is recommended that you read
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 4
    (227) 8.0 (227) 8.1 (230) 9.5 (269) 9.6 (267) 9.7 (265) Shipping Weight ALL REFRIGERATOR / ALL FREEZER MODELS BI-36R BI-36RG BI-36F OVER-AND-UNDER MODELS BI-30U BI-30UG BI-36U BI-36UG SIDE-BY-SIDE MODELS BI-36S BI-42S BI-42SID BI-42SD BI-48S BI-48SID BI-48SD lbs (kg) 420 (191) 430 (195) 406 (184
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 5
    Dimensions OVER-AND-UNDER MODELS 30" (762) 24" (610) 5 subzero.com/specs 36" (914) 24" (610) 84" (2134) 503/4" (1289) 84 BI-30U AND BI-30UG 23" (584) HEIGHT DIMENSIONS ± 1/2" (13) 4" (102) 237/8" (606) 237/8" (606) 235/8" (600) 17" (432) 371/4" (946) 23/8" (60) MODELS BI-36U AND BI-36UG
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 6
    Model Specifications Overall Dimensions SIDE-BY-SIDE MODELS 36" (914) 24" (610) 84" (2134) 733/4" (1873) 6 42" (1067) 24" ( 222) 237/8" (606) 121/2" (318) 261/4" (668) 23/8" (60) MODEL BI-36S Overall dimensions are based on stainless steel models. For flush inset applications, add 1/2" (13) to
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 7
    Model Specifications Overall Dimensions SIDE-BY-SIDE MODELS 48" (1219) 24" (610) 84" (2134) 733/4" (1873) HEIGHT DIMENSIONS ± 1/2" (13) 4" (102) 237/8" (606) 93/4" (248) 14" (356) 237/8" (606) 30" (762) 23/8" (60) MODELS BI-48S, BI-48SID AND BI-48SD 7 subzero.com/specs
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 8
    DEPTH 83 3/4" (2127) OPENING HEIGHT A OPENING WIDTH SIDE VIEW FRONT VIEW Opening Width BI-36R, BI-36RG and BI-36F BI-30U and BI-30UG BI-36U and BI-36UG BI-36S BI-42S, BI-42SID and BI-42SD BI-48S, BI-48SID and BI-48SD A 351/2" (902) 291/2" (746) 351/2" (902) 351/2" (902) 411/2" (1054) 471
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 9
    Site Preparation 9 subzero.com/specs Opening Dimensions FLUSH INSET INSTALLATION 26 3/16" 24" DETAIL B SIDE VIEW Flush Inset Opening Widths BI-36R, BI-36RG and BI-36F BI-30U and BI-30UG BI-36U and BI-36UG BI-36S BI-42S, BI-42SID and BI-42SD BI-48S, BI-48SID and BI-48SD FRONT VIEW A 351/2" (902)
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 10
    VIEW 24" (610) OPENING DEPTH 83 3/4" (2127) OPENING HEIGHT A OPENING WIDTH SIDE VIEW Opening Widths Two 30" (762) Models 30" (762) and 36" (914) Models Two 36" (914) Models FRONT VIEW A 593/4" (1518) 653/4" (1670) 713/4" (1822) IMPORTANT NOTE: A dual installation kit will be required for this
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 11
    Site Preparation 11 subzero.com/specs Dual Installation Opening Dimensions 3 FLUSH INSET INSTALLATION 26 3/ 32) SIDE VIEW FRONT VIEW DETAIL B Opening Widths Two 30" (762) Models 30" (762) and 36" (914) Models Two 36" (914) Models A B 593/4" (1518) 621/4" (1581) 653/4" (1670) 681/4" (1734)
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 12
    specifications are different for the flush inset application, whether you are using custom panels or Sub-Zero accessory flush inset panels. Make sure the opening dimensions, door and drawer clearances, electrical service and plumbing are correct for the model you are about to install. The floor
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 13
    Site Preparation 13 subzero.com/specs Plumbing Requirements All built not use self-piercing valves. A saddle valve kit is available through your authorized Sub-Zero dealer. The water line must not interfere with installation of the anti-tip brackets bar) Excess Water Line for Connection 36" (914)
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 14
    -tip brackets for a stable installation, use all anti-tip bracket hardware as instructed for wood or concrete floors. IMPORTANT NOTE: For either wood or concrete floor the back holes of the brackets, use the provided #8-18 x 11/4" PH truss HD screws and #12 flat washers with the nylon zip-it wall
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 15
    subzero.com/specs Anti-Tip Bracket Installation WOOD FLOOR APPLICATIONS After properly locating the anti-tip brackets in the rough opening, drill pilot holes 3/16" (5) diameter maximum in the wall studs or wall plate. Use the #12 x 21/2" PH torque. Always wear safety glasses and use other necessary
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 16
    two grille screws. Check for proper fit. GRILLE HEIGHT ADJUSTMENT The grille was designed to rest on the upper door hinge(s) to minimize the reveal between the top of the door and bottom of the grille. To eliminate potential interference of the grille and hinge, the grille height can be adjusted
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 17
    Built-In Installation 17 subzero.com/specs Position the Unit Before moving the built-in unit into position, secure door(s) closed and protect , so it can be moved into position more easily. If possible, keep the door(s) closed until the unit is properly anchored. The rear levelers must be in their
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 18
    the rear roller base adjustment. When the unit is properly leveled, door and drawer adjustments are less likely to be necessary. IMPORTANT NOTE: surrounding cabinetry. This could affect the operation of the unit, such as door closing. To reduce the possibility of the unit tipping forward, the front
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 19
    height adjustment. Panel Installation If your customer has ordered either a framed or overlay model, you will be installing door panel(s) to give the unit the custom Sub-Zero look. Before you begin installing panels, refer to the panel specifications for framed, overlay or flush inset applications
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 20
    kickplate must be removable for service. The floor cannot interfere with removal. Refer to the label mounted on the kickplate support for height clearance. Reinstall the grille following the instructions on page 16. Turn power back on to the electrical outlet. 90° DOOR STOP The doors of all built-in
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 21
    Built-In Installation 21 subzero.com/specs Water Filtration System WATER FILTER BYPASS Purification System All Sub-Zero built-in units, except model BI-36F, come with an advanced air purification system. A factory installed air purification cartridge is located inside the refrigerator section, on
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 22
    can be found in the Sub-Zero design guide and on our website, subzero.com. If the thickness of DOOR TRIM REVEAL 1/4" (6) min ROUT TO 1/4" (6) MAIN FRAME DOOR Panels 1/4" (6) thick or less. Panels thicker than 1/4" (6). Framed Panel Requirements MAX WEIGHT PER PANEL BI-36R, BI-36RG and BI
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 23
    subzero.com/specs Framed Panels To install framed panels, the door handle(s) must be removed. To install framed panels, first remove the door trim molding. For side-by-side models and the upper door refrigerator doors. Slide the panel into the frame on the door to the Sub-Zero design guide for a
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 24
    Panel Installation 24 Framed Panel Specifications A H A AH W BI-36R / BI-36F B W BI-36RG A H A AH H W BI-30U / BI-36U A H W BI-30UG / BI-36UG Models BI-36R, BI-36RG and BI-36F REFRIGERATOR / FREEZER Door Panel W 353/4" (908) BI-36RG Window Cut-Out Cut-Out Location W 251/2" (648) A
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 25
    25 subzero.com/specs Framed Panel Specifications H H A B W W W W BI-36S / BI-42S / BI-42SID BI-42SD / BI-48SD BI-48S / BI-48SID Model BI-36S REFRIGERATOR Door Panel FREEZER Door Panel W 1913/16" (503) W 157/16" (392) H 699/16" (1767) H 699/16" (1767) Models BI-42S, BI-42SID and BI-42SD
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 26
    Sub-Zero design guide and on our website, subzero.com. IMPORTANT NOTE: The size of the overlay panel is critical. It must fit over the door into the channel. Overlay Panel Requirements MAX WEIGHT PER PANEL BI-36R, BI-36RG and BI-36F All Other Overlay Models Grille Panel MIN PANEL THICKNESS All
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 27
    refrigerator door panel will need to accommodate a cut-out for the glasswell bezel. To remove the glasswell bezel for an overlay or flush inset model BI-42SD or BI- air flow to the compressor area and cause problems with the operation of the Sub-Zero unit. LOCK INDICATOR ICE WATER LIGHT WATER
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 28
    28 Overlay Panel Specifications H H A H H A H A AH H A AH W BI-36R / BI-36F B W BI-36RG H W BI-30U / BI-36U A H W BI-30UG / BI-36UG Models BI-36R, BI-36RG and BI-36F REFRIGERATOR / FREEZER Overlay Panel Spacer Panel Backer Panel W 36" (914) 351/8" (892) 353/4" (908) H 693
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 29
    Panel Installation 29 subzero.com/specs Overlay Panel Specifications H H H H A B W W W W BI-36S / BI-42S / BI-42SID BI-42SD / BI-48SD BI-48S / BI-48SID Model BI-36S REFRIGERATOR Overlay Panel Spacer Panel Backer Panel FREEZER Overlay Panel Spacer Panel Backer Panel GRILLE Overlay Panel
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 30
    in the Sub-Zero design guide and on our website, subzero.com. BI-36R, BI-36RG and BI-36F All Other Flush Inset Models Grille Panel MIN PANEL THICKNESS All Flush Inset Panels 75 lbs (34 kg) 50 lbs (23 kg) 13 lbs (6 kg) 5/8" (16) Sub-Zero will slide easily into the door frame. The illustration below
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 31
    Installation 31 subzero.com/specs Flush Inset Panels Install the handle hardware before inserting the panel. Sub-Zero recommends using larger on side-by-side models and the upper door for over-and-under models, insert the top of the trim molding problems with the operation of the Sub-Zero unit.
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 32
    Panel Installation 32 Flush Inset Panel Specifications H H A H H B H A AH H A AH W BI-36R / BI-36F B W BI-36RG H W BI-30U / BI-36U B H W BI-30UG / BI-36UG Models BI-36R, BI-36RG and BI-36F REFRIGERATOR / FREEZER Flush Inset Panel Spacer Panel Backer Panel W 37" (940) 351/8" (892
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 33
    Panel Installation 33 subzero.com/specs Flush Inset Panel Specifications H H H H A B W W W W BI-36S / BI-42S / BI-42SID BI-42SD / BI-48SD BI-48S / BI-48SID Model BI-36S REFRIGERATOR Flush Inset Panel Spacer Panel Backer Panel FREEZER Flush Inset Panel Spacer Panel Backer Panel GRILLE
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 34
    library section of our website, subzerotrade.com. Panel Offsets ALL REFRIGERATOR / ALL FREEZER Door / Grille Sides Grille Top Grille Bottom / Door Top Door Bottom OVER-AND-UNDER Door / Drawer / Grille Sides Grille Top Grille Bottom / Door Top Door Bottom / Drawer Top Drawer Bottom SIDE-BY-SIDE
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 35
    need to provide the necessary screws to attach the brackets. IMPORTANT NOTE: If you have a model BI-30U, BI-30UG, BI-36U or BI-36UG, extra routing will be necessary to avoid having the panel hit the refrigerator lower hinge plate. Place the panel at a 75° angle and engage the front brackets into the
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 36
    required. Contact your authorized Sub-Zero dealer for the proper components and installation instructions. For questions regarding the installation, call Sub-Zero at 800-222-7820. For local dealer information, visit the find a showroom section of our website, subzero.com. DUAL STANDARD INSTALLATIONS
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 37
    Dual Installation 37 subzero.com/specs Dual Installation-Flush Inset Panel Specifications H H A H H B H A AH H A AH W BI-36R / BI-36F B W BI-36RG H W BI-30U / BI-36U B H W BI-30UG / BI-36UG Models BI-36R, BI-36RG and BI-36F REFRIGERATOR / FREEZER Flush Inset Panel Spacer Panel
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 38
    dimensions. Exceeding dimensions could cause damage to the panels and the Sub-Zero unit. 5 TOP VIEW DOOR / DRAWER / GRILLE BACKER SPACER CABINETRY DOOR TOP VIEW DUAL TRIM DOOR FLUSH INSET PANEL 5/16" (8) 1/2" (13) 5/8" (16) 5/16" (8) 1/8" (3) 1/4" (6) REVEAL Illus. A Illus. B CABINETRY
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 39
    contact & support section of our website, subzero.com or call Sub-Zero customer care at 800-222-7820. When calling for service, you will need the model and serial numbers of your unit. Both numbers are listed on the product rating plate, located at the top frame of the unit inside the door. Refer
  • Sub-Zero BI-36S | Built-In Installation Guide - Page 40
    SUB-ZERO, INC. P. O. BOX 44848 MADISON, WI 53744 SUBZERO.COM 800.222.7820 7022648 REV-B 7/2011
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

INSTALLATION GUIDE
Built-In Refrigeration