Rane CP52S CP52S Installation Manual

Rane CP52S Manual

Rane CP52S manual content summary:

  • Rane CP52S | CP52S Installation Manual - Page 1
    CP52S COMMERCIAL PROCESSOR INSTALLATION GUIDE L2 L3 L1 P PROGRAM SELECT 46 2 8 0 10 LEVEL ZR1 Program and Level Remote SCP1S Equalizer Security Cover Contents 2 4 5 6 7 8 8 10 14 15 16 17 20741
  • Rane CP52S | CP52S Installation Manual - Page 2
    Only use attachments and accessories specified by Rane. 12. Use only with the cart . 14. Refer all servicing to qualified service personnel. Servicing is required when the all mounting holes to provide the best support. WARNING: To reduce the risk of and maintenance instructions in the literature
  • Rane CP52S | CP52S Installation Manual - Page 3
    . 11. N'utilisez que des accessoires recommandés par Rane. 12. N'utilisez que les éléments de transport, stands 14. Adressez-vous à du personnel qualifié pour tout service après vente. Celui-ci est nécessaire dans n'importe et utilisé conformément aux instructions, peut également provoquer des interfé
  • Rane CP52S | CP52S Installation Manual - Page 4
    12 • 6 • 0 • 6 • 12 40 100 250 630 1.6k 4k 10k POWER CP52S COMMERCIAL PROCESSOR Quick Start If you were the type that cheated on school book reports by just skimming through the " on page 10. Please follow it to encounter fewer problems and reduce the need to increase our collective phone bills. WEAR
  • Rane CP52S | CP52S Installation Manual - Page 5
    CP52S COMMERCIAL PROCESSOR SCP1S Equalizer Security Cover General Description The CP52S is a versatile commercial preamplifier designed for use in restaurants, bars, health clubs and offices. The CP52S serves one stereo Zone. One gated Paging Input and four stereo Program Inputs are provided. A
  • Rane CP52S | CP52S Installation Manual - Page 6
    +16 OFF ON 0 10 0 10 SIG OL -20 +20 LIMIT 24 5 8 10 12 EQ + 12 • 6 • 0 • 6 • 12 40 100 250 630 1.6k 4k 10k POWER CP52S COMMERCIAL PROCESSOR 15 16 1 PAGING INPUT TRIM control adjusts the Page Input preamplifier gain to match the microphone / source in use. The range is 30 dB to
  • Rane CP52S | CP52S Installation Manual - Page 7
    CP52S COMMERCIAL AUDIO 100-240 V EQUIPMENT 24TJ 50/60 Hz 12 WATTS R ZONE REMOTE PROGRAM LEVEL D1 D0 MIN MAX Vr Vc ACN 001 RANE 8 7 6 5 432 1 1 PAGING INPUT Euroblock connector may be wired per instructions in"CP52S Connections" on page 8. 2 MIC PHANTOM POWER switch, when ON, enables +15
  • Rane CP52S | CP52S Installation Manual - Page 8
    CP52S COMMERCIAL PROCESSOR CP52S CP52S or is of a type that might create grounding problems, use isolation transformers. When connecting any CP52S The CP52S supports CP52S COMMERCIAL AUDIO 100-240 V EQUIPMENT 24TJ 50/60 Hz 12 WATTS R ZONE REMOTE PROGRAM LEVEL D1 D0 MIN MAX Vr Vc ACN 001 RANE
  • Rane CP52S | CP52S Installation Manual - Page 9
    CP52S COMMERCIAL PROCESSOR ZR1 Zone / Level L2 L3 L1 P PROGRAM SELECT 4 6 2 8 0 10 LEVEL Decora plate (not included) J1A type of wire required is influenced by your installation and local electrical codes. Rane Corporation does not provide or source cable. Please contact your local retail
  • Rane CP52S | CP52S Installation Manual - Page 10
    630 1.6k 4k 10k CP52S COMMERCIAL AUDIO 100-240 V EQUIPMENT 24TJ 50/60 Hz 12 WATTS R ZONE REMOTE PROGRAM LEVEL D1 D0 MIN MAX Vr Vc ACN 001 RANE CORP. MADE IN OFF ON 100 Hz / 7 kHz +15V POWER CP52S COMMERCIAL PROCESSOR INPUT +- +- PREFLIGHT CONTROL SETTINGS PAGING SETTINGS: • MIC
  • Rane CP52S | CP52S Installation Manual - Page 11
    POWER CP52S COMMERCIAL PROCESSOR CP52S COMMERCIAL AUDIO 100-240 V EQUIPMENT 24TJ 50/60 Hz 12 WATTS R ZONE REMOTE PROGRAM LEVEL D1 D0 MIN MAX Vr Vc ACN 001 RANE CORP. remote functions correctly (see page Manual-4). 12. Adjust the Equalizer as desired. SECURITY Rane offers a few options to
  • Rane CP52S | CP52S Installation Manual - Page 12
    CP52S COMMERCIAL PROCESSOR Specifications Parameter MIC/LINE PAGING INPUT ..........Input Type ..........RFI Filter ..........Gain range ..........Frequency Response ..........Input Referred Noise ..........CMRR ..........THD+NS Specification Balanced Yes +30 to +
  • Rane CP52S | CP52S Installation Manual - Page 13
    CP52S COMMERCIAL PROCESSOR Parameter OUTPUTS: Type ..........Zone Out Gain: Program In From Page Inputs ..........Expand Out Gain: Zone From Page or Program In ..........Frequency Response ..........S/N ..........THD+N ..........Crosstalk ..........Output
  • Rane CP52S | CP52S Installation Manual - Page 14
    CP52S COMMERCIAL PROCESSOR Example System: Restaurant and Lounge CD JUKEBOX MUSIC SERVICE "SATELLITE AUDIO" 11 17 70:00 TRANSFORMER MENU MP3 PLAYER CP52S COMMERCIAL AUDIO 100-240 V EQUIPMENT 24TJ 50/60 Hz 12 WATTS R ZONE REMOTE PROGRAM LEVEL D1 D0 MIN MAX Vr Vc ACN 001 RANE CORP.
  • Rane CP52S | CP52S Installation Manual - Page 15
    MENU Wireless Mic Receiver CP52S Commercial Processor CP52S COMMERCIAL AUDIO 100-240 V EQUIPMENT 24TJ 50/60 Hz 12 WATTS R ZONE REMOTE PROGRAM LEVEL D1 D0 MIN MAX Vr Vc ZONE OUTPUT EXPAND OUTPUT RIGHT +- LEFT +- MONO EXPAND +- SOURCE LEVEL ACN 001 RANE CORP. MADE IN U.S.A. 345
  • Rane CP52S | CP52S Installation Manual - Page 16
    CP52S COMMERCIAL PROCESSOR Technical Support CP52S operate in Mono mode? Yes. The CP52S has a Zone 1 Mono Switch on the rear panel. When Zone 1 of the CP52S to the CP52S remote control terminals the CP52S. If all works fine now, the problem lies Calibration Procedure in the manual. If the above options
  • Rane CP52S | CP52S Installation Manual - Page 17
    "AES48-2005: AES standard on interconnections -Grounding and EMC practices - Shields of connectors in audio equipment containing active circuitry." Rane's policy is to accommodate rather than dictate. However, this document contains suggestions for external wiring changes that should ideally only
  • Rane CP52S | CP52S Installation Manual - Page 18
    circuit is low, and even though the voltage is low, the current is high, thanks to Mr. Ohm, without whose help we wouldn't have these problems. It would take a very high resolution ohm meter to measure the impedance of the steel chassis or the rack rails. We're talking thousandths of
  • Rane CP52S | CP52S Installation Manual - Page 19
    Well, some does, and since 1993, more of it does. That's when Rane started manufacturing some of its products with balanced inputs and outputs tying pin 1 proper grounding practices were in effect. Unbalanced equipment is another problem: it is everwhere, easily available and inexpensive. All those
  • Rane CP52S | CP52S Installation Manual - Page 20
    It is true that an entire system of properly grounded equipment, without ground lift switches, is guaranteed (yes guaranteed) to be hum free. The problem is most equipment is not (both internally and externally, AC system wise) grounded properly. Most units with ground lifts are shipped so the unit
  • Rane CP52S | CP52S Installation Manual - Page 21
    to an earth ground using a star washer for a reliable contact. (Rane always provides this chassis point as an external screw with a toothed washer , 1992). 8. Macatee, RaneNote: "Grounding and Shielding Audio Devices," Rane Corporation, 1994. 9. Philip Giddings, "Grounding and Shielding for Sound and
  • Rane CP52S | CP52S Installation Manual - Page 22
    CABLE CONNECTORS FEMALE BALANCED XLR (NOT A TRANSFORMER, NOR A CROSS-COUPLED OUTPUT STAGE) To Input MALE BALANCED XLR ¼" BALANCED TRS (TIP-RING-SLEEVE) ¼" OR 3.5mm UNBALANCED TS (TIP-SLEEVE) UNBALANCED RCA BALANCED EUROBLOCK 1 2 3 4 + to + - to - B B SHIELD NC FEMALE BALANCED XLR (
  • Rane CP52S | CP52S Installation Manual - Page 23
    From Output To Input FEMALE 1 1=SHIELD 2=RED 3=BLACK 2 C3 1 RED BLACK SHIELD 2-CONDUCTOR SHIELDED CABLE FEMALE 2 1=SHIELD 2=RED 3=BLACK 2 C3 1 RED BLACK SHIELD FEMALE 3B 1=SHIELD 2=RED 3=NC 2 C3 1 RED SHIELD FEMALE 4B 1=SHIELD 2=RED 3=NC 2 C3 1 RED SHIELD 2-CONDUCTOR SHIELDED
  • Rane CP52S | CP52S Installation Manual - Page 24
    SHIELDED CABLE BLACK T=RED S=BLACK + CROSS-COUPLED OUTPUT ONLY: CONNECT BLACK TO SHIELD AT THIS END AND SET GROUND LIFT SWITCH TO 'GROUNDED' (IF PRESENT). ©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5000 USA TEL 425-355-6000 FAX 425-347-7757 WEB www
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

CP52S
COMMERCIAL PROCESSOR
INSTALLATION GUIDE
PROGRAM SELECT
LEVEL
8
2
10
0
4
6
L1
L3
L2
P
SCP1S Equalizer Security Cover
ZR1 Program and
Level Remote
Contents
2
4
5
6
7
8
8
10
14
15
16
17
Important Safety Instructions
Quick Start
General Description
CP52S Front Panel
CP52S Rear Panel
CP52S Connections
ZR1 Remote
Recommended Calibration Procedure
Example System: Restaurant and Lounge
Example System: Cardio Fitness Room
Technical Support
Sound System Interconnection
20741