LiftMaster MA Quick Start Guide

LiftMaster MA Manual

LiftMaster MA manual content summary:

  • LiftMaster MA | Quick Start Guide - Page 1
    Function, and Fail Safe (Auto Open on AC Power Failure). B The S3 DIP switch is a service switch used to open and close the barrier arm from the SAMS (Sequence Access Management System). A DIP Switches ON ON S1 S2 1 2345678 1 2345678 OFF OFF B Manual Switch MANUAL OPEN S3 CLOSE J5
  • LiftMaster MA | Quick Start Guide - Page 2
    Clutch Option; when the barrier arm is manually forced UP (OPEN), the barrier arm will automatically CLOSE. such as Counters, Alarms, Buzzers, and SAMS (Sequence Access Management System), can be wired into the K1 Relay and the count memory is reset to zero. I FAIL SAFE (AUTO OPEN ON AC POWER FAILURE)
  • 1
  • 2

J5
2
3
4
5
6
7
8
9
1
J5
S3
OPEN
CLOSE
MANUAL
PWR
DC
NO
NC
C
AUX RELAY
J1
K1
24VAC XFMR
BAT+
MOTOR
ACC+ ACC– BAT–
MOTOR
J4
B
l
u
e
w
i
r
e
O
r
a
n
g
e
w
i
r
e
S1
1
2
3
4
5
6
7
8
1
OFF
OFF
ON
ON
2
3
4
5
6
S2
7
8
CAM POSITION
MODELS MADCBB, MATDCBB, MASDCBB, & MASTDCB
This Quick Start is intended to highlight the features and functions of the Mega Arm Gate Operator. Refer to the
installation manual for complete information regarding installation and programming.
INTRODUCTION
The operator functions can be customized by changing various DIP switches, and wiring auxiliary devices to the
control board on the J5 terminal strip.
DEFAULT SETTINGS ARE AS FOLLOWS:
• Timer-to-Close is activated and set to four seconds.
• Radio receiver is wired to open only.
• The barrier arm is set to right-hand gate operation.
NOTE:
Right-hand or left-hand operation is
determined by facing the control board
with the barrier
arm in the CLOSED position. If the barrier arm is to the right, it is set for right-hand gate operation.
• Motor speed is set to approximately 2.5 seconds of fast run time.
• Fail Safe is set for Auto Open after batteries drop below 50%.
OVERVIEW
The S1 and S2 DIP switches work together with devices wired into the J5 terminal strip. The DIP switch
settings can be set to control various features such as K1 Relay (optional), Timer-to-Close, Single Button
Function, and Fail Safe (Auto Open on AC Power Failure).
The S3 DIP switch is a service switch used to open and close the barrier arm from the control board.
NOTE:
The S3 DIP switch should be set to CLOSE for normal operation.
The J5 terminal strip is used for controlling the barrier arm with various accessories such as Receivers,
Loop Detectors, Access Controls, and Push Button Stations.
The J4 Motor Wiring is controlled by DIP switch S1-7. The gate operator default setting
for DIP switch S1-7 is in the OFF position, and set for right-hand gate operation.
The K1 Relay (optional) and terminal strip (J1) are used for auxiliary devices such as Counters, Alarms,
Buzzers, and SAMS (Sequence Access Management System).
A
B
C
F
DIP Switches
Manual Switch
K1 Relay (optional) and Terminal Strip (J1)
Limit Cam Position
J5 Terminal Strip (Wiring Inputs)
J4 Motor Wiring
(Factory default right-hand gate operation shown below.)
A
B
C
D
E
D
E
QuickStart
programming guide for MEGA Arm Gate Operators