Konica Minolta AccurioPress 6120 manual content summary:
- Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 1
USB TO RS-232 ADAPTER User's Manual UMC-201 / UMC-102 / UMC-104 / UPR-202 1-51 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 2
Pin Assignment Windows OS Installation Guide 5 Win 98 ...7 Installation Uninstalling Troubleshooting Win 2000 ...15 Installation Uninstalling Troubleshooting Win CE ...22 Installation Troubleshooting Win XP ...27 Installation Uninstalling Troubleshooting VISTA,( Win 7 & Win 8/8.1 38 Installation - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 3
USB to Serial converter provides an external plug-and-play connection for RS-232 enabled devices with PC or any computerizing devices that support the USB specification. The converter comes with the standard connectors of Serial DB-9 and USB Type A or B to fulfill your working requirements. With - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 4
Specification Model No. Chipset USB Specification Data Speed USB Serial Connector Host Device Power Mode Cable Length Housing UMC-201 DB-9/M 1.1m PVC UMC-102 UPR-202 FTDI USB 1.1/2.0 compliant 1.5 / 12 Mbps 230 kbps USB A/M DB-9/M*2 DB-9/M & Mini DIN Bus 0.6 m Plastic UMC-104 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 5
Windows OS Installation Guide Driver can be installed through Windows Update automatically (Internet connection needed) The FTDI drivers that have passed the WHQL tests are available for download using - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 6
device successfully. Fig. 5 NOTE: It may occur when driver is not installed successfully, please check below steps. 1. There is busy on access databank of Microsoft's Support link. Please try again or install driver of CD-ROM provided. 2. Check your internet if it is failed to access Microsoft - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 7
Windows 98 Installation Guide If a device of the same type has been installed on your machine before and the drivers that are about to be installed are different from those installed already, the original drivers need to be uninstalled. Please refer to the uninstalling instruction. Download the - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 8
Check the box next to "Specify a location" and uncheck all others as shown below. Click "Browse" and locate the driver files. Once the files have been located, click "Next" to proceed with the installation. Windows may display a message reading "Building driver database" at this point which may take - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 9
If the driver being installed does not have Microsoft WHQL signature files (.CAT files), the wizard will request a driver disk to attempt to find them. Click "OK" on the "Insert Disk" message box. The following window will appear to assist in locating the file. To proceed with the installation - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 10
Under Windows 98, the COM port emulation driver will be automatically installed from the same location as the serial converter driver. However, if the driver is not WHQL certified as explained above for the serial converter driver, the wizard will ask for the location of .CAT files. Click "OK" on - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 11
the drivers we provided in this CD, you may download the updated or appropriate versions from FTDI Web site www.ftdichip.com/Drivers/VCP.htm supported device "FT232BL(M)". 11-51 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 12
To uninstall drivers, follow the instructions below: Disconnect any devices that are attached to the PC. Open the Add/Remove Programs utility located in "Control Panel\Add/Remove Programs". Select "FTDI - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 13
When the uninstaller has finished removing the device from the system, the caption on the "Cancel" button will change to "Finish". Click "Finish" to complete the process. 13-51 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 14
Troubleshooting 1. Windows 98 cannot find drivers for my device This error can occur persists, please contact the FTDI support department. 4. Device hangs randomly during operation under Windows 98 This is not caused by the driver, but is a hardware compatibility problem. Some newer USB 2.0 hubs - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 15
Windows 2000 Installation Guide If a device of the same type has been installed on your machine before and the drivers that are about to be installed are different from those installed already, the original drivers need to be uninstalled. Please refer to the uninstalling instruction. Download the - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 16
Check the box next to "Specify a location" and uncheck all others as shown below. Clicking "Next" displays a dialog box for you to enter to the location of the drivers. 16-51 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 17
Click "Browse" to display an open file dialog box. Locate the folder containing the latest drivers downloaded from the FTDI web site above and click "Open", then click "OK". The PC auto selects the correct INF file, in this case FTDIBUS.INF. Once Windows found the required driver .INF file, please - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 18
Windows should then display a message indicating that the installation was successful. Click "Finish" to complete the installation for the serial converter driver for this port of the device. The COM port emulation driver must be installed after this has completed. By examining the Device Manager ( - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 19
the drivers we provided in this CD, you may download the updated or appropriate versions from FTDI Web site www.ftdichip.com/Drivers/VCP.htm, supported device "FT232BL(M)". 19-51 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 20
Uninstalling Instruction When uninstalling devices from Windows 2000, it should always be done through the Add/Remove Programs utility as this uses the FTDI driver uninstaller program - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 21
Troubleshooting 1. Windows 2000 cannot find drivers for my device This error can be used in the EEPROM and INF/INI files. 2. Windows 2000 forces a reboot after installing a device This problem can occur if an application is accessing a file while the New Hardware Wizard is trying to copy it. This - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 22
Windows CE Installation Guide Download the latest available drivers for the required processor model from the FTDI website and unzip them, the critical CD, you may download the updated or appropriate versions from FTDI Web site www.ftdichip.com/Drivers/VCP.htm, supported device "FT232BL(M)". 22-51 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 23
Troubleshooting 1. "Unidentified USB Device" dialog is not displayed when device is connected for the first time If the "Unidentified USB Device" dialog is not displayed when - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 24
3. "Error installing USB driver ftdi_ser.dll" message The following installation error may be displayed for a number of reasons: The driver name has been miss pelt · The ".dll" file extension may be required for some platforms · The required driver files are not in the \\Windows directory · The - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 25
of 0x0403 (1027) and a PID of 0x6010 (24592) device. If this is not the device to be installed, the message will recur. To solve the problem, the INF files must be edited to accommodate the required VID and PID. For the D2XX drivers, edit the bold red entries in the following - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 26
very tolerant of noisy hardware, so even "good" designs for Windows 2000 and XP may experience problems with Windows CE. Another issue that has arisen with Windows CE is that different host devices support different bulk transfer sizes. One method to attempt to resolve this is to reduce In Transfer - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 27
Guide original drivers need to be uninstalled. Please refer to the Uninstalling instruction. Download the latest available drivers from the FTDI web site driver it finds for the device in preference to the driver manually selected. Figure 2.1 Select "Install from a list or specific location - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 28
Select "Search for the best driver in these locations" and enter the file path in the combo box ("C:\CDM 2.02.04" in Figure 2.3 below) or browse to it by clicking the browse button. Once the file path has been entered in the box, click next to proceed. Figure 2.2 Figure 2.3 If Windows XP is - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 29
The screen shown in Figure 2.5 will be displayed as Windows XP copies the required driver files. Figure 2.4 Figure 2.5 Windows should then display a message indicating that the installation was successful (Figure 2.6). Click "Finish" to complete the installation for the first port of the device. If - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 30
The Found New Hardware Wizard will launch automatically to install the COM port emulation drivers. As above, select "No, not this time" From the options and click "Next" to proceed with the installation (Figure 2.7). Figure 2.6 Figure 2.7 Select "Install from a list or specific location (Advanced)" - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 31
Select "Search for the best driver in these locations" and enter the file path in the combo box ("C:\CDM 2.02.04" in figure 2.9 below) or browse to it by clicking the browse button. Once the file path has been entered in the box, click next to proceed. Figure 2.8 Figure 2.9 If Windows XP is - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 32
The screen shown in Figure 2.11 will be displayed as Windows XP copies the required driver files. Figure 2.10 Figure 2.11 Windows should then display a message indicating that the installation was successful (Figure 2.12). Click "Finish" to complete the installation for the first port of the device. - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 33
Open the Device Manager (located in "Control Panel\System" then select the "Hardware" tab and click "Device Manger") and select "View > Devices by Connection", the device appears as a "USB Serial Converter" with an additional COM port with the label "USB Serial Port" (Figure 2.13). If the device is - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 34
files for the driver package, simply run DPInst.exe and the certified driver package will be installed on the machine. The current driver package supports 32bit and 64bit systems through common INF files. DPInst has separate executables for 32bit and 64bit installation. This means that if a single - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 35
only. Under Windows XP, driver files and OEM INF and PNF files must be removed manually or by using a custom application. OEM INF and PNF files are located in the bus layer has been removed first. Instructions on how to display phantom devices are given in the Advanced Driver Options application note. - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 36
Troubleshooting themselves. 2. Windows XP Forces a Reboot after Installing a Device This problem can occur if an application is accessing a file while the New Hardware hub with other devices), or may indicate a more serious hardware problem. Also, it may be indicative of USB root hub drivers being - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 37
4. Windows XP Displays An Error And Then Terminates Installation If the following screen is displayed with this message, Windows XP has been configured to block the installation of any drivers that are not WHQL certified. Figure 4.1 Two options are available to successfully install the device. - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 38
Installation Guide Connect the device to a spare USB port on your PC. If there is an available Internet connection, Windows VISTA (Win 7, Win 8)will silently connect to the Windows Update website and install any suitable driver it finds for the device in preference to the driver manually selected - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 39
Select "I don't have the disk. Show me other options" The next screen will appear. Select "Browse my computer for driver software (advanced)". The next screen will appear. Browse to the folder where the CDM driver has been stored (when uncompressed) and press "Next" The example shown above uses a - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 40
The next screen will appear. This screen will automatically complete and then change to the one below: The bus layer of the driver is now installed. After the driver is installed it is important to determine which COM port has been assigned to the device for configuring the application that will use - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 41
the drivers we provided in this CD, you may download the updated or appropriate versions from FTDI Web site www.ftdichip.com/Drivers/VCP.htm, supported device "FT232BL(M)". 41-51 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 42
Uninstalling Instruction With the release of Microsoft Windows Vista, the FTDI uninstaller 2003 do not have this check box, so driver files and OEM INF and PNF files must be removed manually or by using a custom application. Some points to note about the new uninstallation method: In the case of - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 43
Troubleshooting 1. Windows VISTA (Win 7, Win 8) can not find drivers for my device This error can occur if the VID and PID programmed into the device EEPROM - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 44
has customized the driver but has not recertified it, then the driver will not load. You should contact your vendor to determine if they will support VISTA x64. 44-51 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 45
MAC OS X Installation Guide Download the driver from the VCP Drivers section of the FTDI web site and save clicking on the FTDIUSBSerialDriver.dmg icon. Click Continue to proceed with the installation and follow the instructions on screen. When the installation is complete, reboot the computer. 45-51 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 46
When the computer has rebooted, plug in the device. If the device is installed properly, you will see entries in the /dev directory: /dev/cu.usbserial-xxxxxxxx /dev/tty.usbserial-xxxxxxxx Where xxxxxxxx is either the device's serial number or, for unserialized devices, a location string that depends - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 47
the Internet account for each user. If you do not know the required details, contact your Internet service provide Please note: 1. For multiple-port converter, each port has to be installed with the driver from FTDI Web site www.ftdichip.com/Drivers/VCP.htm, supported device "FT232BL(M)". 47-51 - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 48
Uninstalling instruction To remove the drivers from Mac OS X, the user must be logged on as root. Root is a reserved username that has the privileges required to - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 49
Troubleshooting 1. How do I know what my device ID is? Launch the System Profiler utility, or work after installing the driver, it is likely to be because the PID is not supported by the driver. If this is the case, contact FTDI Support with the PID that needs to be added to the driver. If the VID - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 50
your device ID and a description of your device. 3. The device cannot be accessed even though the device ID is Supported in FTDI USBSerial Driver An ownership or permissions problem is preventing the system from making the device accessible. Check that the driver is owned by root and wheel. The - Konica Minolta AccurioPress 6120 | Plockmatic SD-350/SD-500 USB to RS-232 Adapte - Page 51
Regulatory Compliance Disclaimer Information in this document is subject to change without notice. The manufacturer does not make any representations or warranties (implied or otherwise) regarding the accuracy and completeness of this document and shall in no event be liable for any loss of profit
1-51
USB TO RS-232 ADAPTER
User’s Manual
UMC-201 / UMC-102 / UMC-104 / UPR-202