    Invacare® Bariatric Bed en Model BAR750 User Manual This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.
  • Invacare BAR750 | User Manual - Page 2
    rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. Making Life
  • Invacare BAR750 | User Manual - Page 3
    Label Locations 5 2.2 BAR 750 Bariatric Bed Specifications 6 3 Safety 7 3.1 General Guidelines 7 3.2 Disposal 14 4 Setup 15 4.1 Receiving 15 4.2 Unpacking 15 4.3 Inspecting 16 4.4 Assembling the Bed 16 4.5 Adjusting the Bed 19 4.6 Inspecting the Assembled Bed 20 4.7 Storing the Bed 20
  • Invacare BAR750 | User Manual - Page 4
    Invacare® Bariatric Bed 1 General 1.1 Symbols Signal words are used in this manual and apply to hazards or unsafe recommendations and information for efficient, trouble-free use. 1.2 Intended Use The bed is intended to be used as a mattress support system. The bed allows for articulation of the
  • Invacare BAR750 | User Manual - Page 5
    2 Overview 2.1 Label Locations Overview The same labels are located on the opposite side of the bed. 1143215-B-01 5
  • Invacare BAR750 | User Manual - Page 6
    Invacare® Bariatric Bed 2.2 BAR 750 Bariatric Bed Specifications MAXIMUM OVERALL WIDTH: WIDTH EXTENDER: MAXIMUM OVERALL LENGTH: (WITH HEADBOARD AND FOOTBOARD) CASTERS: BACK ANGLE: SHIPPING WEIGHT: WEIGHT LIMITATION: 48 inches (121.9 cm) 39
  • Invacare BAR750 | User Manual - Page 7
    completely reading and understanding these instructions and any additional instructional material such as user manuals, service manuals or instruction sheets supplied with this product or optional equipment. Continued use of the product with damaged parts could lead to the product malfunctioning
  • Invacare BAR750 | User Manual - Page 8
    Invacare® Bariatric Bed DANGER! Risk of Death, Injury or Damage To reduce the risk of shock: - Unplug from the outlet before servicing. - Close supervision is necessary when the product is used by, or near children and/or disabled persons. - Use this product only for its intended use
  • Invacare BAR750 | User Manual - Page 9
    prior to using the Invacare bed and bed rails. User manuals are available at www.invacare.com or your dealer. - After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. - Mattress platform, bed ends, pendant and accessories are applied parts. 9
  • Invacare BAR750 | User Manual - Page 10
    Invacare® Bariatric Bed DANGER! Risk of Death, Injury or Damage Conditions such as restlessness, mental deterioration and dementia or seizure disorders (uncontrolled body movement), sleeping problems, and incontinence can significantly impact a patient's risk of entrapment. Pediatric patients or
  • Invacare BAR750 | User Manual - Page 11
    Invacare mattresses. Non-Invacare mattresses are potentially incompatible with Invacare beds. - To avoid injury, ensure that only Invacare mattresses are used with Invacare beds When used with a manual/electric bed, the bed rails DO NOT fall under any weight limitations. Bed rails can be deformed or
  • Invacare BAR750 | User Manual - Page 12
    MUST fit firmly against the bed frame AND bed side rails to prevent patient entrapment. Follow the manufacturer's instructions. Monitor patient frequently. Read and understand the User Manual prior to using this equipment. Invacare manuals are available at www.invacare.com or your dealer. - An
  • Invacare BAR750 | User Manual - Page 13
    for Invacare products. - Junction box MUST be securely connected to the bed with metal screws and the spacer provided for proper grounding. Otherwise, electrical shock may occur. WARNING! Risk of Injury or Damage To avoid injury or damage from improper grounding or using damaged parts
  • Invacare BAR750 | User Manual - Page 14
    Invacare® Bariatric Bed Weight Limitations DANGER! Risk of Death, Injury or Damage To avoid bed collapse and resulting injury or damage: - The weight limit of the occupant of the bed CANNOT exceed 675 pounds. The TOTAL weight limit of the bed (including accessories, mattress, occupant and any other
  • Invacare BAR750 | User Manual - Page 15
    Assembly instructions parts could lead to the bed malfunctioning, causing injury to the user and/or caregiver. - Check ALL product components and carton for damage, and test components before use. In case of damage or if the product is not working properly, contact a qualified technician or Invacare
  • Invacare BAR750 | User Manual - Page 16
    Invacare® Bariatric Bed 4.3 Inspecting DANGER! Risk of Injury or Damage To avoid injury or damage, inspect the following and contact a qualified technician or Invacare if any of the following issues are present: - Pendant secured properly. - Keep all moving parts, including the main frame, mattress
  • Invacare BAR750 | User Manual - Page 17
    of the foot-end section. 5. Locate two clevis pins C (one each side of bed) on backrest of head-end section which connect shipping brace to bed. 10. Remove shipping bracket and two cardboard support blocks from foot-end bed section. 11. Unlock the casters on the foot-end section. 12. Place power
  • Invacare BAR750 | User Manual - Page 18
    Invacare® Bariatric Bed 15. From the outside of the bed, insert a clevis pin into each side frame hole F. Secure clevis pins using rue rings on inside of frame. 18. Remove lock-pin J from support leg K located under foot-end section. 16. Secure the actuators I to the frame section G using two
  • Invacare BAR750 | User Manual - Page 19
    Adjusting Length 1. Pull down on the release knob A located under the head section of the bed. Setup Adjusting Width 1. Pull down on the release knob C located under the side of the bed. 2. Pull the length extender B out six inches. 3. Release the knob and push the extender in until the knob locks
  • Invacare BAR750 | User Manual - Page 20
    Invacare® Bariatric Bed 4. Repeat STEPS 1 to 3 for the other four side sections E on that side of the bed. 5. Repeat STEPS 1 to 4 for the other side of the bed. 4.6 Inspecting the Assembled Bed Examine each item carefully for scratches, nicks, dents or any other apparent damage. Check all parts for
  • Invacare BAR750 | User Manual - Page 21
    use of multiple functions at one time. - To ensure trouble free operation, ALWAYS allow a slight pause between multiple adjustments and If any problems arise during the test, recheck all electrical connections and mechanical hook ups. A three-function pendant is used for all bed operations which:
  • Invacare BAR750 | User Manual - Page 22
    Invacare® Bariatric Bed Raising and Lowering DANGER! Risk of Death, Injury or Damage Pendant malfunction may cause injury or damage. - Unplug bed from electrical outlet and contact qualified technician or Invacare for repair if any malfunction is detected. Entire Bed Head and Foot Sections 1. To
  • Invacare BAR750 | User Manual - Page 23
    type. Locking the Casters The steering lock function allows you to easily steer the bed in a straight line. 1. Lower the bed to the lowest position. Refer to Operating the Bariatric Bed section. 2. At the head end of the bed, step down on the front of either caster pedal until it clicks. DO NOT
  • Invacare BAR750 | User Manual - Page 24
    Invacare® Bariatric Bed DETAIL "A" - UNLOCKED DETAIL "B" - LOCKED Unlocking the Casters To allow the bed to be rolled next to a stretcher, unlock all four casters. 1. Step down on the back of the control pedal A on each caster. 5.3 Adjusting the Bed Rail DANGER! Risk of Death, Injury or Damage To
  • Invacare BAR750 | User Manual - Page 25
    . - To avoid injury, ensure that only Invacare mattresses are used with Invacare beds at all times. 1143215-B-01 Operation DANGER! Risk of Death, Injury or Damage To avoid entrapment, product damage and/or personal injury: - When used with a manual/electric bed, the bed rails DO NOT fall under any
  • Invacare BAR750 | User Manual - Page 26
    entrapment. Follow the manufacturer's instructions. Monitor patient frequently. Read and understand the user manual prior to using the Invacare bed and bed rails. User manuals are available at www.invacare.com or your dealer. - After any adjustments, repair or service and before use, make sure
  • Invacare BAR750 | User Manual - Page 27
    this manual. The effective bed lifetime can vary according to the frequency and intensity of use. 6.2 Wear and Tear Normal wear and tear items and components include, but are not limited to the items in the table: Wear and Tear Items Hand Pendants Casters -tread wear, brake levers Invacare reserves
  • Invacare BAR750 | User Manual - Page 28
    Invacare® Bariatric Bed 1. Stand or prop each bed end in an upright position on its legs. 2. Using a mild soap/detergent and soft bristle brush or sponge, scrub all exterior surfaces. 3. Using a hose and nozzle attachment, rinse bed ends thoroughly with plain cold or warm water. Do not exceed a
  • Invacare BAR750 | User Manual - Page 29
    cover and end caps. 1143215-B-01 Maintenance Electrical Inspection and Maintenance q Inspect all electrical bed components for damage or excessive wear (i.e., cracked or broken housings, or worn components). q Check pendant, power and motor cords for chafing, cuts or excessive wear. q Make sure all
  • Invacare BAR750 | User Manual - Page 30
    Invacare® Bariatric Bed 7 Troubleshooting 7.1 Troubleshooting: Electrical SYMPTOM Bed section does not move. Bed functions do not operate. . Ensure Pendant correctly connected to junction box under the bed. Ensure Pendant cable is not entangled/pinched. Check fuse/breaker box. Call Invacare. Check
  • Invacare BAR750 | User Manual - Page 31
    is working satisfactorily. If problem actuator now operates "OK", but actuator that was operating "OK" now has a problem, either the control module 7.2 Troubleshooting: Mechanical SYMPTOM PROBABLE CAUSE Bed does not stay in place. Locking casters not locked. Pressing function on Pendant results
  • Invacare BAR750 | User Manual - Page 32
    Invacare® Bariatric Bed 8 Warranty 8.1 Limited Warranty THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the original purchaser who purchases this product when new and unused from Invacare or a
  • Invacare BAR750 | User Manual - Page 33
    Notes
  • Invacare BAR750 | User Manual - Page 34
    Notes
  • Invacare BAR750 | User Manual - Page 35
    Notes
  • Invacare BAR750 | User Manual - Page 36
    Invacare Corporation USA One Invacare Way Elyria, Ohio USA 44035 800-333-6900 www.invacare.com Canada 570 Matheson Blvd E. Unit 8 Mississauga Ontario L4Z 4G4 Canada 800-668-5324 1143215-B-01 2016-08-11 *1143215B-01* Making Life's Experiences Possible™ Product Distributed by Invacare
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

InvacareĀ® Bariatric Bed
en
Model BAR750
User Manual
This manual MUST be given to the user of the product.
BEFORE using this product, read this manual and save for future reference.