Invacare BAR600IVC Owners Manual

Invacare BAR600IVC Manual

Invacare BAR600IVC manual content summary:

  • Invacare BAR600IVC | Owners Manual - Page 1
    Invacare®IVC™Model BAR600IVC Bariatric Bed User Manual EN For more information regarding bed rail safety, refer to the Bed Rail Entrapment Risk Notification Guide at www.invacare.com. This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for
  • Invacare BAR600IVC | Owners Manual - Page 2
    in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. Invacare®IVC™Model BAR600IVC Bariatric Bed 2 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 3
    22 6 TROUBLESHOOTING 24 Troubleshooting: Electrical...24 Troubleshooting: Mechanical ...25 7 ASSEMBLY, MAINTENANCE AND ADJUSTMENT SECTIONS - FOR DEALERS ONLY 26 Overview of Procedures ...26 8 PACKAGING, HANDLING AND SET-UP 27 Part No 1123842 3 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 4
    -Up...30 Storing the Beds ...45 9 MAINTENANCE 46 Washing Bed Ends ...46 Cleaning Head and Foot Sections ...47 Maintenance Checklist ...47 10 TROUBLESHOOTING 50 Troubleshooting: Electrical...50 Troubleshooting: Mechanical ...51 Invacare®IVC™Model BAR600IVC Bariatric Bed 4 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 5
    1 GENERAL 1.1 Symbols Warnings Signal words are used in this manual and apply to hazards or unsafe practices which could result in is not avoided. Gives useful tips, recommendations and information for efficient, trouble-free use. Part No 1123842 5 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 6
    any subsequent purchaser or owner. Coverage under this service, please contact the dealer from whom you purchased your Invacare product. In the event you do not receive satisfactory warranty service, please write directly to Invacare Invacare®IVC™Model BAR600IVC Bariatric Bed 6 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 7
    Locking Tab Head Motor Cable Crossover Cable P/N 1171770 Rev A Part No 1123842 2 OVERVIEW Serial number label located here. Power Cord equipment is connected to a receptacle marked "Hospital Only" or "Hospital Grade". Rev D (1) 02/00 P/N 034059 7 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 8
    2 OVERVIEW NOTE: Labels located on bed frame. Invacare®IVC™Model BAR600IVC Bariatric Bed 8 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 9
    , occupant and any other objects positioned on the bed) *NOTE: Height from floor to bed deck. 2.3 Bed Components: • Head spring with one motor (BAR5000IVC) • Foot spring with two motors (BAR5490IVC) • Bed Ends (BAR5301IVC) 2 OVERVIEW Part No 1123842 9 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 10
    instructions and any additional instructional material such as owner's manuals, service manuals or instruction parts for shipping damage and test before using. In case of damage, DO NOT use. Contact Invacare/Carrier for further instruction. Invacare®IVC™Model BAR600IVC Bariatric Bed 10 Part
  • Invacare BAR600IVC | Owners Manual - Page 11
    - Connect this bed to a properly grounded outlet only. Refer to Grounding Instructions on page 16. 10. Risk of injury to persons - DO NOT place video equipment such as televisions or computer monitors on bed. SAVE THESE INSTRUCTIONS Part No 1123842 11 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 12
    sections are connected securely to the bed ends before use. The pendant and power cords MUST be routed and secured properly to ensure that the cords DO NOT become entangled, pinched and/or severed during operation of the electric bed. Invacare®IVC™Model BAR600IVC Bariatric Bed 12 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 13
    .com for additional safety information. Mattress MUST fit bed frame and bed rails snugly to reduce the risk of entrapment. After any adjustments, repair or service and before use, make sure all attaching hardware is tightened securely. Part No 1123842 13 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 14
    from the original equipment supplied or specified by the bed frame manufacturer are not interchangeable. Variations in bed side rail design, width and thickness or firmness of the mattress could cause/contribute to entrapment. Invacare®IVC™Model BAR600IVC Bariatric Bed 14 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 15
    boxes. No user serviceable parts are inside. Only qualified technicians are permitted to repair these parts. If unqualified individuals perform any work on these beds, the warranty is connections will cause permanent product damage. Part No 1123842 15 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 16
    the surface of the manual/electric bed. DO NOT lay, sit or lean in such a way that your entire body weight is placed only on raised head or foot sections of the bed. This includes when repositioning or transferring in or out of bed. Invacare®IVC™Model BAR600IVC Bariatric Bed 16 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 17
    trouble bed function. Depending on severity of the initial overheating, this could take up to 30 minutes. The emergency crank MUST be removed before the bed is used. Failure to remove the crank may cause damage or personal injury. Part No 1123842 17 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 18
    the test, recheck all electrical connections and mechanical hook ups. 2. A six-function pendant is used for all bed operations. 3. An emergency crank allows operation in the event of a power outage. Invacare®IVC™Model BAR600IVC Bariatric Bed 18 FIGURE 1 Operating Bariatric Bed Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 19
    end of the head section or the motor shaft end of the foot section. 3. Crank clockwise or counterclockwise to adjust the bed.  Push in the emergency crank while turning it the desired direction. 4. Remove the emergency crank. Part No 1123842 19 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 20
    the optional bed rails without reading and understanding the Bed Rail Risk Notification Guide that accompanies this manual and is included with each bed rail kit. The Bed Rail Risk Notification Guide can also be found at www.invacare.com. Invacare®IVC™Model BAR600IVC Bariatric Bed 20 Part No
  • Invacare BAR600IVC | Owners Manual - Page 21
    Stand or prop each bed end in an upright bed end and all components. 6. Repeat drying process until all components are dry.  Ensure that the bed end is completely dry before storing. Gear Box Bed End Part No 1123842 FIGURE 1 Washing Bed Ends 21 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 22
    bed components for damage or excessive wear (i.e., cracked or broken housings, or worn components). ❑ Check pendant, power and motor cords for chafing, cuts or excessive wear. ❑ Make sure all plugs are fully attached and free of damage. Invacare®IVC™Model BAR600IVC Bariatric Bed 22 Part
  • Invacare BAR600IVC | Owners Manual - Page 23
    bed is ready for placement into a client's home. ❑ FAIL: Bed, or any component, has failed any of the preceding inspection criteria. Tag the bed or component with a complete description of the failure(s) and have the bed serviced. Part No 1123842 23 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 24
    work. Cables Household fuse or breaker blown. Motors are not functioning. Hi/Lo Motor Bed Spring does not stop moving. Bed Hi/Lo movement does not stop. Pendant Invacare®IVC™Model BAR600IVC Bariatric Bed SOLUTIONS Operate opposite button. Ensure power cord is plugged into power source. Ensure
  • Invacare BAR600IVC | Owners Manual - Page 25
    gear box shaft. Drive shaft disconnected. Motor cable connections to junction box incorrect. 6 TROUBLESHOOTING SOLUTIONS Lock casters. Check pull tube(s) for binding. Call dealer for repairs. Call dealer. Call dealer. Call dealer. Part No 1123842 25 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 26
    Spring Sections ❑ Installing/Removing Bed Ends ❑ Installing Casters ❑ Connecting Crossover Cable. Refer to Set-Up - Connecting Crossover Cable on page 37. ❑ Assembling/Installing/Removing the Drive Shaft ❑ Inspecting the Bed Storing Invacare®IVC™Model BAR600IVC Bariatric Bed 26 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 27
    contact Invacare Customer Service department at (800) 333-6900. 8.2 Unpacking The bed is contained in three cartons. 1. Check bed components bed controls prior to completion of assembly. Otherwise, damage to bed components may occur. Part No 1123842 27 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 28
    Bed Ends 1. The foot section carton includes: • One foot section (including pendant, junction box with power cord and foot and hi/lo motors with cables). • One emergency crank handle. 2. The head section carton includes: • One head section. Invacare®IVC™Model BAR600IVC Bariatric Bed 28 Part
  • Invacare BAR600IVC | Owners Manual - Page 29
    plug. 2. Inspect the junction box for any damage to the connectors. 3. Ensure that the motor plugs are plugged into the junction box and fit properly. Part No 1123842 29 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 30
    of the bed from the packing carton. 3. Remove tie-wraps securing the cables for shipping (FIGURE 3 on page 31).  Place the foot section on a flat surface so that the motor guards on the bottom of the frame are supporting the foot section. Invacare®IVC™Model BAR600IVC Bariatric Bed 30 Part No
  • Invacare BAR600IVC | Owners Manual - Page 31
    Connecting Crossover Cable on page 37. 9. Assemble and install the drive shaft. Refer to Assembling/Installing/Removing Drive Shaft on page 40. 10. Activate the bed functions. Refer to Inspecting the Bed on page 44. Part No 1123842 31 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 32
    one side of bed, pull the release pin and pull the head section so that it starts to separate slightly from the foot section. 7. On the opposite side of bed, pull the release pin. 8. Separate the head section from the foot section. Invacare®IVC™Model BAR600IVC Bariatric Bed 32 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 33
     Motor guards located on underside of frame sections. Foot Section 8 PACKAGING, HANDLING AND SET-UP Foot Section (Inside) Head Section (Inside) Locking Pin Part No 1123842 Head Section FIGURE 4 Assembling/Disassembling Head and Foot Sections 33 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 34
    the casters. Refer to Installing Casters on page 35. Bed End Rivets Corner Plate Head Rivets Corner Plate Head Rivets Rivets Bed End Head Section Corner Locks FIGURE 5 Installing/Removing Bed Ends Foot Section Corner Locks Invacare®IVC™Model BAR600IVC Bariatric Bed 34 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 35
    two locking casters by pushing down on the caster lock.  Locking the casters may not prevent the bed from moving on slick or slippery surfaces. 4. To unlock each of the two locking casters, push down on the caster lock labeled off. Part No 1123842 35 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 36
    8 PACKAGING, HANDLING AND SET-UP Bed End Caster Socket Caster Shaft Non-Locking Caster Caster Shaft Locking Caster Caster Socket Unlocked Locked Locking Caster FIGURE 6 Installing Casters Invacare®IVC™Model BAR600IVC Bariatric Bed 36 Locking Caster Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 37
    head actuator. 3. Gently pull the crossover cable toward the junction box so that any slack in the cable is taken up near the junction box. Part No 1123842 37 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 38
    . Mis-alignment of cable connections will cause permanent product damage. Locking Lever Locking Tab Head Motor Cable Crossover Cable P/N 1171770 Rev A FIGURE 7 Connecting Crossover Cable Invacare®IVC™Model BAR600IVC Bariatric Bed 38 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 39
    CABLE Side Channel Slack in Crossover Cable Junction Box Foot End of Bed Head End of Bed Part No 1123842 CAUTION All cable connections MUST be aligned properly. Align locking Cable P/N 1171770 Rev A FIGURE 8 Connecting Crossover Cable 39 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 40
    to FIGURE 10. 4. Attach the inner shaft to the bottom gear box output shaft on the head end of the bed. 5. Push in on the spring loaded end of the drive shaft and attach to the Hi/Lo motor output shaft facing the head end of the bed. Invacare®IVC™Model BAR600IVC Bariatric Bed 40 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 41
    Shaft 6. Locate the Hi/Lo motor output shaft spring-loaded coupler.  If necessary, shift the bed end to the right or left to align the Hi/Lo motor output shaft spring-loaded coupler with box as shown in Detail "A" of FIGURE 10. Part No 1123842 41 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 42
    . 9. Ensure that all components are securely installed. ƽ WARNING Close the drive shaft covers over all drive shafts that are not in use before placing the bed in service. Otherwise, damage or injury may occur. Invacare®IVC™Model BAR600IVC Bariatric Bed 42 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 43
    8 PACKAGING, HANDLING AND SET-UP DETAIL "A" Hi/Lo Motor Output Shaft Spring-Loaded Coupler Bed End Unlocked Position Drive Shaft Hi/Lo Motor Output Shaft (Full Electric Only) Hi/Lo Motor Drive Shaft FOOT END HEAD END Gear Box Part No 1123842 43 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 44
    8 PACKAGING, HANDLING AND SET-UP Inspecting the Bed ƽ WARNING The removal and installation of cables are to in Detail "A" in FIGURE 11). 4. Before placing bed into use, test the bed by operating it through all phases of operation. Invacare®IVC™Model BAR600IVC Bariatric Bed 44 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 45
    the Beds ƽ WARNING DO NOT place other objects on top of the cartons. If bed is not being assembled immediately, retain the cartons and packaging for storage until ready for assembly. Store the Invacare homecare bed in a dry area. Part No 1123842 45 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 46
    trapped water to drain. 5. Thoroughly towel dry bed end and all components. 6. Repeat drying process until all components are dry.  For this procedure, refer to FIGURE 1. Ensure that the bed end is completely dry before storing. Invacare®IVC™Model BAR600IVC Bariatric Bed 46 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 47
    bed with disinfectant. Allow it to dry completely. 9.3 Maintenance Checklist Invacare recommends the following maintenance and cleaning procedures be conducted between users or as needed. This form is provided as a guide excessive wear. Part No 1123842 47 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 48
    Broken or deformed connectors  If these conditions are present, the bed MUST not be used until the damaged component/wiring is replaced. Modification or other forms or repair including electrical or similar tape MUST NEVER be used. Invacare®IVC™Model BAR600IVC Bariatric Bed 48 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 49
    the bed is ready for placement into a client's home. ❑ FAIL: Bed, or any component, has failed any of the above inspection criteria. Tag the bed or component with a complete description of the failure(s) and have the bed serviced. Part No 1123842 49 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 50
    drive shaft is correctly installed. Bed Spring does not stop moving. Pendant Check for depressed/stuck buttons. If button is stuck, call dealer for repair. Bed Hi/Lo movement does not stop. Check cables. If damaged, call dealer. Invacare®IVC™Model BAR600IVC Bariatric Bed 50 Part No 1123842
  • Invacare BAR600IVC | Owners Manual - Page 51
    Troubleshooting: Mechanical SYMPTOM PROBABLE CAUSE Bed does not stay in place. Locking casters not locked. Bed sections do not move. Pull tube Bed ends move in opposite directions (electrical or manual bed . Refer to FIGURE 11. Part No 1123842 51 Invacare®IVC™Model BAR600IVC Bariatric Bed
  • Invacare BAR600IVC | Owners Manual - Page 52
    Part No 1123842 Rev H - 4/11 Invacare Corporation USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 www.invacare.com Canada 570 Matheson Blvd E Unit 8 Mississauga Ontario L4Z 4G4 Canada 800-668-5324
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

User Manual
This manual MUST be given to the user of the product.
BEFORE using this product, read this manual and save for future reference.
EN
Invacare
®
IVC
Model BAR600IVC
Bariatric Bed
For more information regarding bed rail safety, refer to the Bed Rail
Entrapment Risk Notification Guide at www.invacare.com.