HP StorageWorks MSA1510i/MSA20 HP StorageWorks 1510i Modular Smart Array insta
HP StorageWorks MSA1510i/MSA20 Manual
![]() |
View all HP StorageWorks MSA1510i/MSA20 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks MSA1510i/MSA20 manual content summary:
- HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 1
HP StorageWorks 1510i Modular Smart Array installation and user guide active/active firmware v2.0 or later Part number: 383070-002 Second edition: May 2008 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 3
9 Document conventions and symbols 10 Rack stability 11 HP technical support 11 Customer self repair 11 Product warranties 11 Subscription service 12 HP websites 12 Documentation feedback 12 1 Overview 13 Product overview 13 MSA1510i product features 13 Front features 14 Rear features - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 4
78 Verifying the operating status of the devices 55 Viewing the LEDs on the MSA1510i 55 Reading startup messages on the controller display panel 56 Troubleshooting 57 4 Configuration 59 Supported management tools 59 Storage Management Utility (SMU) overview 59 MSA Command Line Interface (MSA - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 5
hard drives that make up an array 101 Changing the management port IP address through the MSA1510i controller display panel 102 6 MSA controller LCD panel message descriptions 105 LCD panel overview 105 notice 133 Power cords 133 1510i Modular Smart Array installation and user guide 5 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 6
137 Latvian notice 137 Lithuanian notice 137 Polish notice 137 Portuguese notice 138 Slovakian notice 138 Slovenian notice 138 Spanish notice 138 Swedish notice 139 B MSA1510i worksheets 141 Index 153 6 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 7
142 9 MSA1510i 2-Port Ethernet iSCSI module IP address information 143 10 Network switch information 145 11 Server information 146 12 Array and unit information 150 13 Target information 151 14 Initiator access information 151 1510i Modular Smart Array installation and user guide 7 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 8
8 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 9
on the MSA1510i Support page: http://www.hp.com/support • HP StorageWorks 1510i Modular Smart Array firmware release notes • HP StorageWorks 1510i Modular Smart Array installation and configuration roadmap poster • HP StorageWorks 1510i iSCSI concepts and deployment guide • HP StorageWorks 1510i - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 10
• Novell Linux: http://www.novell.com • HP-UX: http://www.hp.com • VMware: http://www.vmware.com Document links and e-mail addresses Blue, underlined text: http://www.hp.com Bold text Website addresses • Keys that are pressed • instructions. NOTE: Provides additional information. 10 About - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 11
service provider. For North America, see the CSR website: http://www.hp.com/go/selfrepair Product warranties For information about HP StorageWorks product warranties, see the warranty information website: http://www.hp.com/go/storagewarranty 1510i Modular Smart Array installation and user guide - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 12
http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 12 About this guide - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 13
MSA1510i. • Product overview • iSCSI overview Product overview • MSA1510i product features • MSA1510i front features • MSA1510i rear features • Shipping contents MSA1510i product features The MSA1510i are supported. • the MSA1510i can supported HP a supported Web service is disabled. • MSA1510i - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 14
drive firmware flashing is supported directly from the SMU using HP Firmware Maintenance CD 7.90 and later. For more information, see the SMU user guide. Front features 1. Blank for an additional controller (controller slot 2) 2. Serial port for a CLI connection 3. MSA1510i controller (controller slot - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 15
for additional 2-Port Ethernet iSCSI module (for the controller in slot 2) 7. Blanks for additional SCSI I/O modules (buses 1, 2, and 3) 1510i Modular Smart Array installation and user guide 15 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 16
Shipping contents 1. 1510i Modular Smart Array (MSA1510i) 2. 2U universal rack mounting kit 3. Printed documents, 2U rack mounting template, and documentation CD 4. Custom CLI configuration cable 5. Power cords newpage pi 16 Overview - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 17
practices IMPORTANT: The following overview is very brief. For additional detail, see the MSA1510i iSCSI concepts and deployment guide, provided on the MSA1510i Support CD v2.0 and MSA1510i support page: http://www.hp.com/support. Targets A target is a grouping of one or more MSA Logical Units (LUNs - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 18
• Disable unused or insecure services (such as telnet). • Change the logon username and password of the Storage Management Utility. 18 Overview - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 19
component LEDs Front view 1. Chassis LEDs 2. Chassis Power On/Standby button 3. Blank for an additional controller (controller slot 2) 4. MSA1510i controller (controller slot 1) 5. Controller LCD message display panel 6. Controller LCD panel push buttons 1510i Modular Smart Array installation and - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 20
Rear view 1. 2-Port Ethernet iSCSI module (for the controller in slot 1) 2. Chassis slot diagram 3. Blank for additional 2-Port Ethernet iSCSI module (for the controller in slot 2) 4. Power supply module 2 5. Power supply module 1 6. SCSI I/O module (bus 0) 7. Blank for additional SCSI I/O module ( - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 21
LCD panel, and system event logs (such as those provided by HP Systems Insight Manager). The following sections define the LEDs. • Chassis LEDs • MSA1510i controller LEDs • Hard drive LEDs • Slot diagram LEDs • 2-Port mode. The power is off. 1510i Modular Smart Array installation and user guide 21 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 22
supply and some internal circuitry remain active. To remove the power completely, disconnect all power cords from the device. For instructions, see "Powering off the MSA1510i" on page 77. Controller LEDs During normal runtime, the array controller has 18 LEDs that indicate controller activity or - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 23
LEDs Each SCSI hard drive has three LEDs. The following figure and table describe their locations and meanings. 1510i Modular Smart Array installation and user guide 23 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 24
. Blinking The hard drive is being accessed in one of the following ways: • The hard drive has been selected for identification in HP-SIM, MSA-CLI, or other supported management utility. • The hard drive is being upgraded. Do not remove the hard drive. Removing a hard drive at this time can cause - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 25
possible. The drive is offline, a spare, or not configured as part of an array. newpage pi 1510i Modular Smart Array installation and user guide 25 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 26
Slot diagram LEDs Located on the rear of the MSA, the slot diagram provides information about MSA modules. 1. 2-Port Ethernet iSCSI module (for the controller in slot 2) 2. SCSI I/O module (bus 3) 3. SCSI I/O module (bus 2) 4. Fan module 1 5. Fan module 2 6. 2-Port Ethernet iSCSI module (for the - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 27
network is established, the status is good, and there is activity on network. There is no network activity. 1510i Modular Smart Array installation and user guide 27 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 28
Fan module LEDs Each fan module has one bi-color LED. This LED can be illuminated with either a green or amber color. The following figure and table describes their locations and meanings. Item Name 1 Status 2 Fault Condition Solid Off Blinking Color Green - Amber Meaning The power is on. The - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 29
power is off. There is activity on this SCSI module. There is no activity on this SCSI module. 1510i Modular Smart Array installation and user guide 29 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 30
Power supply module LEDs The power supply uses a single bi-color LED to indicate status. This LED can be illuminated with either a green or amber color. The following figure and table describes their locations and meanings. Item Name 1 Status 2 Fault Condition Solid Off Blinking Color Green - - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 31
information • Troubleshooting information Use this iSCSI concepts and deployment guide to develop guide, be sure to pay special attention to any listed "best practices." The iSCSI concepts and deployment guide is provided on the MSA1510i Support CD and MSA1510i support page: http://www.hp.com/support - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 32
guide is available on the Manuals page of the MSA1510i support page: http://www.hp.com/support , promotions and services. • Online HP StorageWorks 1510i Modular Smart Array, HP StorageWorks 20 Modular Smart Array, and HP StorageWorks 30 Modular Smart Array. 5. Follow the on-screen instructions - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 33
of the outstanding customer advisories before installing the MSA1510i. Advisories are available on the MSA1510i support page: http://www.hp.com/support. On this page, click See support and troubleshooting information. Also look for Troubleshoot a problem. Determining who will install and configure - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 34
http://www.hp.com/go/san Read the HP SAN Design reference guide, which details hp.com/servers/networking Support: http://www.hp.com/support Subscriber's Choice notification service: http://www.hp.com/go/e-updates Sign up to receive e-mail notifications about your MSA1510i, including alerts and service - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 35
or other supported models) • Hard drives • Confirm that the hardware and software components you plan to use are supported for use with the MSA1510i. Before troubleshooting purposes. Use the checklist on the poster or in the back of this guide. • Consider reading the HP SAN design guide. This guide - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 36
based on I/O loads of the LUNs. • Manual load balancing-Through the SMU or CLI, indicate see for a detailed list of MSA1510i specifications. Providing structural support for the floor Calculate the total verify that your site can support the weight. For HP ProLiant server environments, consider using - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 37
fully and provide at least 30 inches (76.2 cm) in the rear of the rack to allow for servicing and airflow. If there are unused spaces in your rack, attach blanking panels across those empty spaces two Uninterruptible Power Supplies (UPS). 1510i Modular Smart Array installation and user guide 37 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 38
/heat dissipation for your installation varies depending on the equipment configuration. Preparing the network Preparing the network for the MSA1510i includes: • Preparing the servers • Preparing the switches NOTE: For optimum network performance, use 1000BaseT Ethernet NICs, 1000BaseT switches, and - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 39
for use with the MSA1510i. For details, see the HP StorageWorks MSA1510i compatibility guide, located on the Manuals page of the MSA1510i support website: http://www.hp.com/support. • Install one or more Ethernet NICs in each server that will access the MSA1510i. For instructions, refer to the - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 40
connect to the MSA1510i. ("Basic MSA1510i information" on page 142) For installation instructions, see the hp.com/ products/servers/proliantstorage/sharedstorage/index.html. • MSA1510i maintenance and service guide, on the MSA1510i Support CD or the MSA1510i support website: http://www.hp.com/support - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 41
. CAUTION: To prevent damage and to ease insertion of the device into the rack, support the weight of the device and keep it level when sliding it into the rack. Racking procedures Use the following instructions to install the MSA1510i: 1510i Modular Smart Array installation and user guide 41 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 42
1. If desired, use the instructions on the provided rack template to mark the holes on the front and rear rack uprights that will be used by the rails. 2. If the - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 43
of the rack until the pins extend through the marked holes and the scissor-pin clicks into place. 1510i Modular Smart Array installation and user guide 43 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 44
to the farthest position near the rear of the rack. 7. Repeat through to install the other rail. 8. Remove the bezel from the front of the MSA1510i by grasping the bezel by its left and right outside edges, and then, with even pressure, pulling toward you until the retaining clips disengage. 9. From - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 45
is flush with the front of the rack. Then, secure the MSA1510i to the front of the rack by tightening the thumbscrews on the front of the MSA1510i. 11. From the rear of the rack, secure the rear of the bezel until the retaining clips engage. 1510i Modular Smart Array installation and user guide 45 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 46
hard drives into the drive bays. For installation instructions, see the documents shipped with the hard drive supported for use with the MSA1510i and your storage enclosure, read the MSA1510i compatibility guide, located on the Manuals page of the MSA1510i support website: http://www.hp.com/support - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 47
label. Connecting SCSI cables To connect the MSA1510i to the storage enclosures, use standard VHDCI SCSI SCSI I/O module(s) are securely seated in the MSA1510i chassis and that the thumbscrews on the SCSI , bus, and preassigned box numbers HP recommends installing additional SCSI I/O modules and - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 48
Item Bus Port Assigned box Assigned box number-SATA number-SCSI A 1 1 0 B 5 1 not used A 2 2 1 B 6 2 not used A 3 3 2 B 7 3 not used A 4 4 3 B 8 4 not used newpage pi 48 Installation - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 49
Supported and unsupported SCSI connections Each SCSI I/O module has two ports. Depending on the type of storage enclosure you plan to connect, one or both of the ports might be supported. Supported Unsupported newpage pi 1510i Modular Smart Array installation and user guide 49 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 50
SATA storage enclosures In the following illustration, two MSA20 SATA storage enclosures are connected to the MSA1510i using the pre-installed MSA SCSI I/O module. 1 MSA1510i controller shelf 2 MSA20 SATA storage enclosure (SCSI bus 0, Box 1) 3 MSA20 SATA storage enclosure (SCSI bus 0, Box - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 51
MSA1510i NOTE: To obtain 1000BaseT performance from the MSA1510i, use 1000BaseT Ethernet NICs, 1000BaseT network and cables in the network cause the MSA1510i to reduce its performance level to that 1 Server 2 iSCSI Ethernet network switch 3 MSA1510i controller shelf newpage pi 4 Storage enclosure ( - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 52
can eliminate downtime caused by power-related failures. When connecting the power cords, use the power cords shipped with the MSA1510i. After power is supplied to the MSA1510i, the power supply automatically senses the input voltage and the LED behind the power switch illuminates as solid amber. 52 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 53
power sources fails due to a pulled cable, tripped breaker. The remaining power source can power the MSA1510i until the failed power source is restored or relocated. Depending on the cause and duration of the power equipment. newpage pi 1510i Modular Smart Array installation and user guide 53 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 54
Powering on the MSA 1. Verify that the following devices are powered on and in a ready state: • Uninterruptible Power Supplies (UPS) • Network switches 2. Power on all attached hard drive storage enclosures. IMPORTANT: Proceed to the next step only after confirming that the external storage - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 55
. If the LEDs indicate a fault, see documentation that came with the device. For information about the MSA1510i, see the MSA1510i maintenance and service guide.http://h18006.www1.hp.com/products/storageworks/msa1510i. IMPORTANT: Depending on the IP address that is automatically assigned to the - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 56
an integrated LCD panel. This panel displays informational and error messages, shows the current status of the MSA1510i, and provides an interface for user input. To verify that your MSA1510i is operating properly, press the arrow buttons on the controller LCD panel and look for the following - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 57
cable connections to the MSA1510i. • Check the availability of your power source. • Review the setup instructions in previous sections of this guide. • Remove and then reinsert the module. • Refer to the HP StorageWorks MSA1510i maintenance and service guide. 1510i Modular Smart Array installation - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 58
58 Installation - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 59
4 Configuration Configuration includes: • MSA1510i supported management tools • Configuration best practices • Configuration overview • Configuring the Microsoft iSCSI initiator • Configuring the VMware iSCSI software initiator Supported management tools The following is a partial list of the tools that - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 60
and write requests • Number of sectors read or written For more information, see the Management CD in the HP ProLiant Essentials Foundation Pack or the HP-SIM website: http://www.hp.com/go/hpsim. Packet InterNet Groper (PING) overview Use the PING utility to check network connections. PING bounces - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 61
MSA1510i using the Network switch information worksheet in the MSA1510i installation and user guide portal group, configure the mapping to manually load balance ownership of the LUNs between the MSA1510i Support CD from the MSA1510i Support page: http://www.hp.com/go/support. Upgrade instructions are - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 62
the controllers based on I/O loads of the LUNs. (Recommended) • Manual (also called explicit) load balancing-Through the SMU or the CLI, configure the Microsoft iSCSI initiator to connect to a dual-controller MSA1510i in a multipathing environment. (For single-controller configurations, omit all - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 63
path to the target. a. Select the Discovery tab. b. In the Target Portals section of the window, click Add. 1510i Modular Smart Array installation and user guide 63 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 64
. However, if the target has not granted access to the initiator, when a logon is attempted, access will be denied. With the implementation of iSNS support, iSNS discovery domain may be put in place to address this issue. The following illustration shows the Discovery tab after adding the portals to - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 65
to select more than once per IP address and target. • Enable multi-path (Multipathing environments only) c. Click Advanced. 1510i Modular Smart Array installation and user guide 65 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 66
d. Expand the drop-down boxes and enter the following settings: • Local adapter: Microsoft iSCSI Initiator • Source IP: Enter the IP address of the NIC that has access to the target portal that you want to connect to (and will enter in the next step). • Target Portal: Select the destination target - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 67
. 5. Verify the connection status to the target. a. On the Targets tab, select the target and then click Details. 1510i Modular Smart Array installation and user guide 67 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 68
NOTE: In multipathing environments only, two sessions should be established: • one for the target portal associated with MSA controller A • one for the target portal associated with MSA controller B b. Select one of the listed sessions and then click Connections. c. View the information in the - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 69
Troubleshooting Problem initiator in the MSA1510i SMU or CLI MSA1510i target portal. • Bad cable connected to the network. • Other network problem; verify connectivity to the management port with ping command. • MSA hardware problem supports MSA1510i. iSCSI configuration was lost during a MSA1510i - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 70
initiators are supported by MSA1510i. This section describes how to configure the VMware iSCSI initiator to connect to a dual-controller MSA1510i in a , they appear on the Static Discovery list. To this list, you can manually add any additional targets, or remove targets you don't need. The static - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 71
ESX Server supports the Challenge Handshake Authentication Protocol (CHAP) that your iSCSI initiators can use for authentication purposes. After your initiator the iSCSI Initiator Properties dialog box. 2. Click the Dynamic Discovery tab. 1510i Modular Smart Array installation and user guide 71 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 72
3. To add a new iSCSI target that your ESX Server host can use for a SendTargets session, click Add. The Add Send Targets Server dialog box displays. 4. Enter the Send Targets server IP address, and click OK. 5. To change or delete a Send Targets server, select the server and click Edit or Remove. - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 73
secret to authenticate the initiator. Any established sessions are not affected. 7. Click OK to save changes. 8. Perform a rescan. 1510i Modular Smart Array installation and user guide 73 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 74
NOTE: If you disable CHAP, all sessions that require CHAP authentication will end immediately. Performing a Rescan If a new LUN becomes accessible through the adapter, then ESX Server registers this new virtual device for use by virtual machines. If an existing LUN is no longer used and appears to - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 75
Troubleshooting Problem Possible cause / solution iSCSI initiator cannot The initiator name in the iSCSI initiator software does not match the name entered add a discovery portal for the initiator in the MSA1510i The controller supports a MSA1510i. iSCSI configuration was lost during a MSA1510i - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 76
76 Configuration - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 77
arrays • Changing the management port IP address through the MSA1510i controller display panel Powering off and powering on the MSA all servers with access to the MSA, or if your operating system fully supports it, quiesce all I/O, disconnect all connections, and dismount all LUNs. 4. guide 77 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 78
Powering on the MSA 1. Verify that the following devices are powered on and in a ready state: • Uninterruptible Power Supplies (UPS) • Network switches 2. Power on all attached hard drive storage enclosures. IMPORTANT: Proceed to the next step only after confirming that the external storage - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 79
additional features and functions, performance enhancements, support for newly released hardware, or fixes of firmware may be placed on the HP website. When determining which version MSA Survey Utility • HP Systems Insight Manager (HP-SIM) • Network HP and MSA websites 1510i Modular Smart Array - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 80
Operating system patch kit Y/N Initiator Y/N Multipathing software Y/N Device Specific Module (DSM) Y/N Switch firmware Y/N SCSI hard drive firmware Y/N MSA1510i firmware Y/N MSA20 firmware Y/N NOTE: To determine the firmware version currently running on an MSA controller, do one of the - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 81
has been more than six months since you restarted your MSA storage system, HP recommends that you power-cycle the MSA (power off, and then power information, see the CLI or SMU user documents. • In dual-controller MSA1510i configurations, you MUST log off all redundant paths to the MSA array guide 81 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 82
problems during the firmware update process, stop and contact HP technical support. See for support contact information. Updating MSA firmware using the SMU NOTE: For complete information about accessing and using the SMU, see the HP Storage Management Utility user guide MSA1510i service instructions - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 83
completion message to display. For example, the following messages are displayed on the MSA controller LCD panel: MSA1510i update: 307 FIRMWARE FLASH DONE MSA20 update: 313 FIRMWARE FLASH DONE ON BOX (Each attached storage LCD panel. 1510i Modular Smart Array installation and user guide 83 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 84
the MSA-CLI This out-of-band, MSA-based updating method is supported for use in most environments, with a few limitations. IMPORTANT: Before methods. The preferred method of updating MSA1510i firmware is with the SMU. See the HP Storage Management Utility user guide for more information. NOTE: For - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 85
host: a. Navigate to the MSA1510i support page: http://www.hp.com/go/support. b. Click the title description changes, important notes, service considerations, and installation update, click Download and follow the on-screen instructions to save the download bundle to a temporary directory guide 85 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 86
CLI> download firmware where: offline -performs an update, but does not automatically restart the MSA; the MSA must be restarted manually. Can be used in single-controller and dual-controller configurations. online-performs an update with an automatic restart upon completion. Can be - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 87
message to display. For example, the following messages are displayed on the MSA controller LCD panel: MSA1510i update: 307 FIRMWARE FLASH DONE MSA20 update: 313 FIRMWARE FLASH DONE ON BOX (Each attached MSA controller LCD panel. 1510i Modular Smart Array installation and user guide 87 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 88
13. View the messages displayed on the array controller LCD panel during startup to confirm that the firmware was installed successfully and that the array controller restarts successfully. NOTE: In dual-controller configurations, firmware on the two controllers is compared each time the MSA chassis is - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 89
the ISO image for the latest ProLiant Firmware Maintenance CD from the following website: http://www.hp.com/support/proliantstorage. Then, burn the image onto a bootable CD using a standard CD-ROM burning utility a browser and access the SMU. 1510i Modular Smart Array installation and user guide 89 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 90
file, select an updating option, and then click OK. XML firmware filenames may be similar to the following: InventoryResultsLinux.xml 7. Wait for the MSA1510i to process the XML file and update the display with a list of all Smart Components that need updating. 8. In the updated display, select a Smart - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 91
to the controller using a serial connection. 1. Go to the MSA1510i support website and obtain the latest controller firmware. NOTE: If you notices about HP products. Information about your MSA is not requested when subscribing to this service. 2. Establish Array installation and user guide 91 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 92
3. Using the emulator transfer (or send file) command, send the firmware to the controller. The following instructions and examples use HyperTerminal. For more information, see user documentation for your emulator program. a. On the menu bar at the top of the HyperTerminal window, - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 93
to preserve the integrity of the local drive, but does require manual intervention to recover or re-enable the LUN. Although controller fi hard drives. For more information on troubleshooting hard drive problems, see the HP ProLiant servers troubleshooting guide. Effects of hard drive failure When - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 94
This is designed to protect the integrity of the LUN, but does require manual intervention to recover or re-enable the LUN. You are likely to lose all I/O activity. 2. Turn off the system as described in Powering off the MSA1510i. 3. Check for loose, dirty, broken, or bent cabling and connectors on - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 95
ADG configuration. Time required for a rebuild The time required for a rebuild varies considerably, depending on several factors: 1510i Modular Smart Array installation and user guide 95 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 96
• The priority that the rebuild is given over normal I/O operations (you can change the priority setting through the Array Configuration Utility (ACU), Storage Management Utility (SMU), or MSA Command Line Interface (MSA-CLI). • The amount of I/O activity during the rebuild operation • The rotational - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 97
• The HP ProLiant servers troubleshooting guide, available on the Management CD • MSA1510i installation and user guide Removing the hard all warnings, cautions, and preparation procedures as detailed in the MSA1510i Maintenance and service guide. 2. Be sure that the Online and Drive Access LEDs are - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 98
4. Pull the hard drive out of the storage enclosure bay (3). Installing the hard drive NOTE: Illustrations in this section demonstrate installing a hard drive in an MSA20 storage enclosure. The procedure for installing a hard drive in an MSA30 or other storage enclosure is similar. 1. Press the hard - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 99
with data from the other hard drives. While reconstruction is in progress, the online LEDs flash. newpage pi 1510i Modular Smart Array installation and user guide 99 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 100
up-to-date information on supported storage enclosures, see the MSA -CLI to configure the new storage. For instructions, see the user documents for the utility. 10 testing has been performed, HP recommends backing up data storage enclosures can be migrated. MSA1510i configurations have one limitation - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 101
identified, power down the system and verify the connections. 16. In MSA1510i configurations, be sure to enter the iSCSI configuration settings and map NOTE: For more information on migrations, go to the HP storage website: http://www.hp.com/go/storage. Migrating the hard drives that make up guide 101 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 102
Depending on your network configuration, this default IP address may not be accessible by the network servers. To change the IP address of the MSA1510i management port to be in the same LAN segment as the network servers, do the following: 1. Access the controller LCD panel management menu. Press the - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 103
that the IP address was entered correctly by pressing ^ or v until the Port #MA0 IP message is displayed. 7. Verify that the server can locate the MSA1510i by opening a command prompt window and using the ping command. 1510i Modular Smart Array installation and user - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 104
104 Operation and management - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 105
at the same time to delete the currently displayed message. The display module consists of the following components: 1510i Modular Smart Array installation and user guide 105 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 106
User input messages For a complete list of messages and their meanings, see "LCD message descriptions" on page 107. Error messages Error messages indicate that a problem has occurred and may require user action to correct it. The array controller Fault LED to the left of the LCD display panel lights - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 107
stops blinking. LCD message descriptions NOTE: Some messages may specify a box number. For the MSA1500 and MSA1510i, the following box numbers are predefined: Predefined box number Physical connection to MSA SCSI I/O module now operational. 1510i Modular Smart Array installation and user guide 107 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 108
single-controller configurations and in dual-controller configurations where both controllers are locked-up, restart the MSA chassis. If the issue persists, contact HP support. An issue has been found with all of the configured volumes that may result in data loss. The exact nature of the issue is - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 109
supported. Contact HP support. ROM flash failed. Download new firmware from the HP website and initiate the firmware update again. If the issue persists, contact HP support firmware from the HP website and initiate the firmware update again. If the issue persists, contact HP support. An online firmware - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 110
any SE devices and replace them with LVD devices. The array controller has been inserted in an MSA chassis in which it is not supported. Contact HP support. The MSA is not properly identifying an external storage enclosure. Do the following: 1. Remove power from the MSA and all attached storage - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 111
information is not valid. The MSA cannot continue to operate and will halt. Contact HP support. Two array controllers are installed, and they are attempting to enter redundant mode. chassis. Should the issue persist, contact HP support. 1510i Modular Smart Array installation and user guide 111 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 112
failed. Manually update the firmware on the older array controller. If volume expansion is in progress then redundancy is not supported. Volume expansion are fully seated in the chassis. Should the issue persist, contact HP support. Both array controllers must run the same version of firmware for - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 113
the issue persist, contact HP support. While either attempting to Should the issue persist, contact HP support. While either attempting to the issue persist, contact HP support. While either attempting to enter Should the issue persist, contact HP support. While operating in redundant mode, - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 114
safely be removed. Remove the other array controller for the planned service. When complete, reinsert the array controller, ensuring that it it is fully seated in the chassis. If the issue persists, contact HP support. The array controller has two cache modules attached but they are of different - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 115
controller, ensuring it is fully seated in the chassis. Should the issue persist, contact HP support. The cache memory hardware has temporarily been disabled, typically because the battery is not charged Command Line Interface (MSA-CLI). 1510i Modular Smart Array installation and user guide 115 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 116
Message Type 71 SYSTEM HALTED FOR CACHE ERROR Error 72 CACHE ERROR IGNORE? =YES User input Description Action This message is displayed upon a no response to message 72 CACHE ERROR IGNORE? =YES . If = 1.1 or 1.2: There is currently only one cache module in the array - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 117
the array controller, ensuring it is fully seated in the chassis. Should the issue persist, contact HP support. A SCSI hard drive that was previously missing or failed has now been replaced with a working SCSI their original positions. 1510i Modular Smart Array installation and user guide 117 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 118
Message 88 NON-HP DRIVE BOX #, BAY Type Informational 89 INVALID CONFIG BOX #, BAY Error 100 VOLUME # STATE OK Informational 101 VOLUME # STATE FAILED Error 102 VOLUME # STATE INTERIM - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 119
with a different new drive. The volume expansion operation on the configured volume has failed. Open the HP Storage Management Utility or MSA-CLI and use it to determine the state of the volume. If the volumes were detected at power up. 1510i Modular Smart Array installation and user guide 119 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 120
controller. The configuration information has been updated. The array controller supports a maximum of 32 configured volumes. More than 32 volumes were been modified so as to allow the migration to proceed. Run the HP Storage Management Utility or MSA-CLI to check the new access controls and modify - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 121
ensuring that it is fully seated in the chassis. If the issue persists, contact HP support. 205 ARRAY CONTROLLER RESTARTING Informational 300 RECOVERY ROM AUTOFLASH STARTED Informational The array controller the backup recovery ROM. 1510i Modular Smart Array installation and user guide 121 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 122
reinsert the array controller ensuring that it is fully seated in the chassis. The ROM cloning process is attempted again. If the issue persists, contact HP support. The array controller in the MSA has started the firmware flash process. Do not turn off power to the system until it has completed - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 123
unable to update the firmware on the iSCSI daughter board. Retry the operation. Contact HP support if the problem persists. Indicates that the array controller has detected out-of-date firmware on a fan . This could take several minutes. 1510i Modular Smart Array installation and user guide 123 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 124
on a fan module. Indicates that the array controller was unable to update the firmware on a fan module. Retry the operation. Contact HP support if the problem persists. The array controller was unable to proceed with a firmware flashing or cloning operation because the cache batteries are low and - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 125
the storage enclosure. Then reapply power to the storage box and then the MSA. If the issue persists, contact HP support. The version of firmware running on the EMU. This is only displayed for the internal EMU of the MSA the back of the MSA. 1510i Modular Smart Array installation and user guide 125 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 126
to the MSA. For more information, see the MSA installation guide. The array controller's PCI subsystem is being initialized as part of persist, contact HP support. An error occurred while programming iSCSI configuration to the iSCSI hardware. Contact HP support if the problem persists. 126 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 127
has failed. Verify that the module is inserted properly into the bay. If the problem persists, replace the module. The Target-Based Management subsystem is being initialized as part of functionality is disabled. Contact HP support. 1510i Modular Smart Array installation and user guide 127 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 128
from the network. The detected MSA processor revision. The array controller has detected a 10 Mb/s link on the indicated Ethernet port. The MSA1510i does not support 10 Mb/s, so communication with this port is not possible. Connect the port to a switch capable of 100 Mb/s or 1000 Mb/s. 128 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 129
both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. The rating label on the device shows which class (A or B) the equipment cause undesired operation. 1510i Modular Smart Array installation and user guide 129 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 130
than those specified herein, or in the laser product's installation guide, may result in hazardous radiation exposure. To reduce the risk of • Do not try to open the module enclosure. There are no user-serviceable components inside. • Do not operate controls, make adjustments, or perform procedures - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 131
• EN61000-3-2 (IEC61000-3-2) - Power Line Harmonics • EN61000-3-3 (IEC61000-3-3) - Power Line Flicker • EN 60950 (IEC 60950) - Product Safety BSMI notice 1510i Modular Smart Array installation and user guide 131 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 132
Japanese notice Korean notice (A&B) Class A equipment Class B equipment Safety Battery replacement notice WARNING! The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 133
and 3.6 m (12 ft). If you have questions about the type of power cord to use, contact an HP authorized service provider. NOTE: Route power cords so that they will not be walked on and cannot be pinched by items static-safe containers. 1510i Modular Smart Array installation and user guide 133 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 134
at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 135
waste equipment for recycling, please contact your local city office, your household waste disposal service, or the shop where you purchased the product. Estonian notice Seadmete jäätmete kõrvaldamine tai liikkeeseen, josta tuote on ostettu. 1510i Modular Smart Array installation and user guide 135 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 136
d'informations sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit. German notice Entsorgung von Altgeräten aus privaten - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 137
łych ze sprzętu elektrycznego i elektronicznego. Osobna zbiórka oraz recykling zużytego sprzętu pomogą w ochronie zasobów 1510i Modular Smart Array installation and user guide 137 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 138
o ambiente e a saúde das pessoas. Para obter mais informações sobre locais que reciclam esse tipo de material, entre em contato com o escritório dan HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido. Slovakian notice Likvidácia vyradených zariadení v dom - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 139
ållsavfall eller affären där du köpte produkten för att få mer information om var du kan lämna ditt avfall för återvinning. 1510i Modular Smart Array installation and user guide 139 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 140
140 Regulatory compliance and safety - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 141
some of the information may be helpful for future configuration changes and troubleshooting purposes. The following worksheets are included in this section: • Basic MSA1510i information • MSA1510i 2-Port Ethernet iSCSI module IP address information • Network switch information • Server information - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 142
information Component Configuration type (check one) MSA1510i chassis serial number Controller firmware version, installed Controller firmware version, Web Installation CD version servers Multipath, multiple clustered servers Yes Yes Yes Yes Yes Yes Yes MSA20 MSA30 142 MSA1510i worksheets - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 143
Component Settings Primary Ethernet iSCSI module, for the controller in slot 1: Location: Rear-left of the MSA1510i Physical port 0 (top port) Logical port SA0 IP address / VLAN ID TCP port TCP port fewer or more IP segments. 1510i Modular Smart Array installation and user guide 143 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 144
2-Port Ethernet iSCSI module IP address information (continued) Component Settings Redundant module, for the controller in slot 2 Location: Rear-right of the MSA1510i Physical port 0 (top port) Logical port SB0 IP address / VLAN ID TCP port TCP port IP address / VLAN ID TCP port TCP - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 145
network switches with VLANs per network switch. Your configuration may have fewer or more switches and VLANs. 1510i Modular Smart Array installation and user guide 145 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 146
Table 11 Server information Component Make and model Operating system, version Service pack and patch kit Server name iSCSI qualified name (iQN) VLAN in this table. Complete one worksheet for each server connected to your MSA1510i. If necessary, create additional copies of this worksheet. 146 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 147
Server information (continued) Component An additional server: Make and model Operating system, version Service pack and patch kit Server name iSCSI qualified name (iQN) VLAN ID : Clustering software and version Cluster cabling 1510i Modular Smart Array installation and user guide 147 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 148
information (continued) Component An additional server: Make and model Operating system, version Service pack and patch kit Server name iSCSI qualified name (iQN) VLAN ID Additional items for clustered configurations: Clustering software and version Cluster cabling 148 MSA1510i worksheets - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 149
Server information (continued) Component An additional server: Make and model Operating system, version Service pack and patch kit Server name iSCSI qualified name (iQN) VLAN ID : Clustering software and version Cluster cabling 1510i Modular Smart Array installation and user guide 149 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 150
Table 12 Array and unit information Array Unit # RAID level Disk members Unit nl capacity Drive type (SCSI/SATA) Spare 150 MSA1510i worksheets - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 151
Table 13 Target information Target Units LUNs IP address/subnet/port MSA portal/portal group/logical port Table 14 Initiator access information Server name iQN name Initiator alias Assigned target VLAN ID 1510i Modular Smart Array installation and user guide 151 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 152
152 MSA1510i worksheets - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 153
Ethernet cables, 51 installing the MSA1510i, 34 iSCSI, 17 performance, , overview, 59 components, 19 supported hard drives, 46 compromised fault tasks, 61 configuring the MSA1510i best practices, 34 choosing , 110 beacon on, 121 begin redundancy support, 111 cache batteries low recharging, 115 cache - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 154
upgrade restarting system, 109 PCI bridge ASIC self-test failure, 126 PCI subsystem hardware failure, 126 persistent mem disabled, 126 pilot 2 contrlr not supported, 109 read failure, 110 recovery ROM autoflash done, 122 recovery ROM autoflash failed, 122 recovery ROM autoflash started, 121 redundancy - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 155
on box #, 124 firmware flash failed, 109 firmware flash failed on box #, 123 fw version is not supported, 110 hard drive failure box, 117 I2C read failure, 110 I2C write failure, 111 invalid config box 3, bay 126 volume expansion failure, 119 1510i Modular Smart Array installation and user guide 155 - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 156
, 41 installing, 46 migrating, 101 from one controller to another, 101 supported, 46 help obtaining, 11, 33 High Availability website, 34 HP series number, 130 Subscriber's Choice for Business, 32 technical support, 11 HyperTerminal emulator program, 85 I indicators fan module, 28 informational - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 157
support assistance, HP, 33 getting started, 31 hard drive, 98 rack-mounting the MSA1510i, 41 guide, 31 iSCSI concepts and deployment guide, 31 iSCSI terminology concepts guide, 31 L laser compliance, 130 latches, hard drive, 97, 99 LCD display, 56 LCD message descriptions, 107 LCD messages at MSA1510i - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 158
using the SMU, 82 MSA1510i overview, 13 MSA1510i compatibility guide website, 46 MSA1510i controller LEDs, 22 MSA1510i controller display panel changing management port IP address, 102 MSA1510i information iSCSI concepts and deployment guide, 31 MSA1510i worksheet, 142 multipath configuration - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 159
support, 36 Subscriber's Choice website, 34 Subscriber's Choice, HP, 12 website, 32 switches at MSA1510i startup, 55 overview of, 17 preparing for use with the MSA1510i support HP, 11 service locator website, 12 text symbols, 10 troubleshooting of switches, 55 of the MSA1510i, 56 views, front and rear - HP StorageWorks MSA1510i/MSA20 | HP StorageWorks 1510i Modular Smart Array insta - Page 160
websites clustering, 34 customer self repair, 11 enclosures, 34 HP , 12 HP documentation, 9 HP Subscriber's Choice for Business, 12 infrastructure, 34 Insight Manager, 34 MSA1510i, 9, 34 multipathing, 34 OS information, 10 related information, 9 servers, 34 Subscriber's Choice, 34 switches, 34
![](/manual_guide/products/hewlettpackard-storageworks-1510i-hp-storageworks-1510i-modular-smart-array-installation-user-guide-383070002-2008-1efa5c4/1.png)
HP StorageWorks
1510i Modular Smart Array installation and
user guide
active/active
fi
rmware v2.0 or later
Part number: 383070–002
Second edition: May 2008