the configuration that Hewlett-Packard supports for the HP NetServer LH 3000, HP Rack Storage/12 and Microsoft Cluster Server. These configurations minimize single points of failure (SPOF) and provide extended availability. The specific configuration certified and supported by both Hewlett-Packard - HP D5970A | HP Netserver LH 3000 NetRAID-3Si Config Guide for Windows 2000 Adva - Page 2
Adv. Server CD or later. For embedded DAC and NetRAID-xSi, use mraid35x.sys version 2.62 (Navigator L.18.04.5 or later). SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed) Any HP cables that meet SCSI specifications and any - HP D5970A | HP Netserver LH 3000 NetRAID-3Si Config Guide for Windows 2000 Adva - Page 3
's for each Rack Storage/12 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure including: HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module - HP D5970A | HP Netserver LH 3000 NetRAID-3Si Config Guide for Windows 2000 Adva - Page 4
the Client LAN NIC must use the same driver as the Intra-cluster NIC. 1 minimum Shared Storage Cabling This part of the guide defines the allowable cabling configurations for clusters using the HP NetServer LH 3000 and HP Rack Storage/12. Only these cabling configurations and cables are supported. - HP D5970A | HP Netserver LH 3000 NetRAID-3Si Config Guide for Windows 2000 Adva - Page 5
HP Microsoft Cluster Server with Rack Storage/12 - HP D5970A | HP Netserver LH 3000 NetRAID-3Si Config Guide for Windows 2000 Adva - Page 6
Power Cabling to Separate Power Sources - HP D5970A | HP Netserver LH 3000 NetRAID-3Si Config Guide for Windows 2000 Adva - Page 7
Versions 3 November 2000 5 September 2000 sym_hi.sys 5.00.2134.1 or later Initial release
![](/manual_guide/products/hewlettpackard-lh3000r-hp-netserver-lh-3000-netraid3si-config-guide-windows-2000-advanced-server-clusters-057b267/1.png)
HP NetServer LH 3000
with
NetRAID-3Si (HP Rack Storage/12)
Windows 2000 Advanced Server
Cluster Configuration Guide
3 November 2000
(see
Versions
at the end of this document)
Introduction
This document defines the configuration that Hewlett-Packard supports for the HP NetServer LH 3000, HP
Rack Storage/12 and Microsoft Cluster Server.
These configurations minimize single points of failure
(SPOF) and provide extended availability.
The specific configuration certified and supported by both
Hewlett-Packard and Microsoft is defined, as are other guidelines to assist you in configuring your
clustered NetServers.
This guide is prescriptive; it describes the configurations supported by HP.
Any
deviance to these configurations can result in an inoperative cluster or an operating cluster with degraded
performance, hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LH 3000
Each node must be the same model SPU, but may have different sizes of
main memory, cache, and different CPU clock speeds.
Installation
Pedestal or racked
Number of nodes
2
Shared Storage
HP Rack Storage /12 with HP NetRAID-3Si controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.