HP D5970A HP Netserver LC 2000 NetRAID-4M Config Guide
HP D5970A - NetServer - LCII Manual
![]() |
View all HP D5970A manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D5970A manual content summary:
- HP D5970A | HP Netserver LC 2000 NetRAID-4M Config Guide - Page 1
and Microsoft® is defined, as are other guidelines to assist you in configuring your clustered Netservers. This guide is prescriptive; it describes the configurations supported by HP. Any deviance to these configurations can result in an inoperative cluster or an operating cluster with degraded - HP D5970A | HP Netserver LC 2000 NetRAID-4M Config Guide - Page 2
drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications and any SCSI bus speed Any Shared Controller Model No. of controllers BIOS Firmware Driver NetRAID-4M FAST HP NetRAID-4M Adapter D9161A or D9351A 2 maximum Disabled 4584 Hpn.sys version 2.4.0.4571 - HP D5970A | HP Netserver LC 2000 NetRAID-4M Config Guide - Page 3
used for client communication. Client LAN Any LAN Embedded NIC Hptxnt.sys 4.02.35 (Navigator L.20.00) or later 1 Any that is on both the HP Tested Products List and the Microsoft® Hardware Compatibility List. Vendor supported driver NOTE If the NIC used is the same as the Intra-cluster LAN - HP D5970A | HP Netserver LC 2000 NetRAID-4M Config Guide - Page 4
local storage. This diagram depicts using slot P5 for the shared storage NetRAID-4M. 3. Cables between the servers and shared storage cabinets can be any HP LVD SCSI (offset) cable up to 10 meters. See "Cables"for Rack Storage/12 in the - HP D5970A | HP Netserver LC 2000 NetRAID-4M Config Guide - Page 5
Power Cabling to Separate Power Circuits 5 - HP D5970A | HP Netserver LC 2000 NetRAID-4M Config Guide - Page 6
Versions 6 June 2001 Initial release © Copyright 2001, Hewlett-Packard Company 6
![](/manual_guide/products/hewlettpackard-lh3000r-hp-netserver-lc-2000-netraid4m-config-guide-414c6d5/1.png)
1
HP Netserver LC 2000
with
NetRAID-4M (HP Rack Storage/12)
Windows NT
Server 4.0 Enterprise Edition
Cluster Configuration Guide
6 June 2001
(see
Versions
at the end of this document)
Introduction
This document defines the configurations that Hewlett-Packard supports for the HP Netserver LC 2000,
HP Rack Storage/12 and Microsoft
Cluster Server.
These configurations minimize single points of
failure (SPOF) and provide extended availability.
The specific configuration certified and supported by
both Hewlett-Packard and Microsoft
is defined, as are other guidelines to assist you in configuring your
clustered Netservers.
This guide is prescriptive; it describes the configurations supported by HP.
Any
deviance to these configurations can result in an inoperative cluster or an operating cluster with degraded
performance, hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in a Cluster
•
Cluster
•
SPUs
•
Local and Shared Storage
•
Intra-cluster and Client LANs
•
Shared Storage Cabling
Cluster
Type of SPUs
HP Netserver LC 2000
Each node must be the same SPU, but may have different clocks speeds,
main memory sizes, cache sizes, and number of CPUs.
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-4M controller and HP disks.
See
Shared Storage
below.
LANs:
Client LAN
Any NIC that is HP and Microsoft
approved.
See
Client LAN
below.
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable or equivalent. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power