    READ AND SAVE THESE INSTRUCTIONS ATOMICAL™ 52" Damp Location Ceiling Fan Owner's Manual Model No. CF930BS02 CF930ORB02 CF930WW02 Net Weight: 18.0 Lbs. Part No. F40BP73320002 Form No. BP7332-2 UL Model No.: CF930
  • Emerson CF930 | Owner Manual - Page 2
    , or working near the fan. Always turn off the power to the ceiling fan before servicing. 4. Do not put anything into the fan blades while they are turning. 5. Do not operate reversing switch until fan blades have come to a complete stop. Additional Safety Instructions for Installation 1. To avoid
  • Emerson CF930 | Owner Manual - Page 3
    sizes: ! WARNING Before assembling your ceiling fan, refer to section on proper method of wiring your fan (Page 9). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician. Unpacking Instructions For your convenience, check-off boxes
  • Emerson CF930 | Owner Manual - Page 4
    COVER C. CEILING COVER D. FAN BLADES E. LOWER HOUSING K. 60-WATT CANDELABRA BULBS F. LIGHT KIT ASSEMBLY G. HANGER BRACKET I. LOWER GLASS J. FAN/LIGHT REMOTE hub in the motor housing assembly. IMPORTANT 3. Remove the fan motor assembly from the protective plastic bag. Place all carton
  • Emerson CF930 | Owner Manual - Page 5
    Emerson Electric SW406 Wall Control may also be used to control your ceiling fan. How to Assemble Your Ceiling Fan ! WARNING To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked "Acceptable for Fan Support DOWNROD SETSCREW Figure 1 5 UL Model No.: CF930
  • Emerson CF930 | Owner Manual - Page 6
    correctly (Figure 3). CEILING CANOPY ! WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed (as shown in Figure 2) could result in the fan falling. HAIRPIN CLIP
  • Emerson CF930 | Owner Manual - Page 7
    ceiling fan on the styrofoam halves, with the fan motor assembly using three M4 x 10mm serrated head screws. Rotate the lower housing to securely tighten by engaging the screws in the two key hole slots (Figure 7). LOWER HOUSING M4 x 10mm SERRATED HEAD SCREW (3) Figure 7 7 UL Model No.: CF930
  • Emerson CF930 | Owner Manual - Page 8
    not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt. LIGHT KIT ASSEMBLY 1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 11). KEY HOLE SLOT (2) Figure 9 8 UL Model No.: CF930
  • Emerson CF930 | Owner Manual - Page 9
    fan could wobble or fall. How to Wire Your Ceiling Fan If ceiling fan must be properly grounded as a precaution against possible electrical shock. 2. Carefully lift the fan CEILING COVER, SUPPLY WIRES AND FAN the fan, light fan and the fan motor wires fan motor white wire to the receiver white (TO MOTOR
  • Emerson CF930 | Owner Manual - Page 10
    AC IN L ANTENNA GREEN GROUND WIRE FROM HANGER BRACKET 1-1/4" THREADED STUD (2) Figure 13 FAN BLACK WIRE FAN BLUE WIRE FAN WHITE WIRE RECEIVER WHITE WIRE TO 120VOLT SUPPLY STANDARD ON-OFF WALL SWITCH OR OPTIONAL SW406 BLUE WHITE BLACK BLUE WHITE HANGER BALL Figure 14 10 UL Model No.: CF930
  • Emerson CF930 | Owner Manual - Page 11
    through the holes in the ceiling cover (Figure 15). 5. Secure the ceiling cover in place by ceiling cover fits snugly against the ceiling. 1-1/4" THREADED STUD (2) #8 EXTERNAL TOOTH LOCKWASHER (2) Figure 15 CEILING not pinched between the ceiling cover and the ceiling. FLAT AREA (3) Figure 17 LOWER
  • Emerson CF930 | Owner Manual - Page 12
    Emerson Ceiling Fan/Light Remote Control consists of hand-held transmitter and a receiver which is mounted under the fan ceiling cover. The remote control is designed to separately control your ceiling fan the transmitter battery compartment and replace the battery cover. 12 UL Model No.: CF930
  • Emerson CF930 | Owner Manual - Page 13
    Fan installation must be completed, including the installation of the fan fan and light (Figure 19). NOTE: Prior to operation of the fan and light from the remote control, set the fan speed to HIGH (....) and turn the light ON ( ). 1. To set the desired fan speed, hold the FAN LIGHT FAN BUTTON LIGHT
  • Emerson CF930 | Owner Manual - Page 14
    INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan ceiling fan Ceiling Fan this fan Emerson Electric Co. could result in personal injury or property damage. Trouble Shooting Remote Control Fan/Light Fails to Operate • Check that the speed switch on the fan fan when close to
  • Emerson CF930 | Owner Manual - Page 15
    FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. TROUBLE 1. Fan will not start. Trouble Shooting Ceiling Fan PROBABLE CAUSE 1. Fuse or circuit breaker blown. 2. Loose power line connections to the fan. 3. Code switches in remote control receiver and Fan/Light Wall Control are not set
  • Emerson CF930 | Owner Manual - Page 16
    REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • PART DESCRIPTION • NAME OF ITEM • MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing. For repair parts, phone 1-800-654-3545. 16 UL Model No
  • Emerson CF930 | Owner Manual - Page 17
    Head, M4 x 10mm (7) 13 Kit, Balancing (1) 14 Cover, Ceiling (1) 15 Cover, Coupling (1) 16 Housing, Lower (1) 17 Harness, Wiring Blade Set (full set for one fan) 21 Receiver, Remote Control (1) 22 Transmitter, SR401 (1) - Owner's Manual (1) Model No. CF930BS02 761655- 17 UL Model No.: CF930
  • Emerson CF930 | Owner Manual - Page 18
    can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that all requirements of the Canadian InterferenceCausing Equipment Regulations. 18 UL Model No.: CF930
  • Emerson CF930 | Owner Manual - Page 19
    . What Will Emerson Electric Co. Do To Correct Problems: Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage CF930
  • Emerson CF930 | Owner Manual - Page 20
    Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP73320002 Printed in China 09/10 Form No. BP7332-2 UL Model No.: CF930
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Part No. F40BP73320002
Form No. BP7332-2
UL Model No.: CF930
READ AND SAVE THESE INSTRUCTIONS
Net Weight:
18.0
Lbs.
ATOMICAL
52” Damp Location
Ceiling Fan Owner's Manual
CF930BS02
CF930ORB02
CF930WW02
Model No.