Dell PowerStore 500T EMC PowerStore Networking Guide for PowerStore T Models
Dell PowerStore 500T Manual
View all Dell PowerStore 500T manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell PowerStore 500T manual content summary:
- Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 1
Dell EMC PowerStore Networking Guide for PowerStore T Models Version 2.x June 2021 Rev. A01 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 2
and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2020 - 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 3
T model initial deployment and storage network configuration 7 Supported switches...8 Part I: Initial Deployment...9 Chapter 2: Initial deployment of PowerStore T model overview 10 Initial deployment of PowerStore T model...10 Chapter 3: Prepare to configure the Management switch and networks - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 4
services 50 Chapter 11: Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-ofRack switches...52 Configuring with Dell EMC Top-of-Rack switches to support NAS networks 63 Chapter 12: Cable Dell PowerSwitch Series ToR switches for Storage services 65 Cable the base enclosure - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 5
with ToR switches and no VLT interconnect......... 79 Steps to configure PowerStore T model with ToR switches without VLT 79 Appendix D: Other Dell EMC PowerSwitch Series configuration operations 80 Dell EMC SmartFabric Services ...80 Reset the switch to factory settings...80 Running configuration - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 6
PowerStore Documentation page at https:// www.dell.com/powerstoredocs. ● Troubleshooting For information about products, software updates, licensing, and service, go to https://www.dell.com/support and locate the appropriate product support page. ● Technical support For technical support and service - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 7
and networks: ● PowerStore Quick Start Guide ● PowerStore Planning Guide ● PowerStore Hardware Information Guide ● Installation and Service Guide for PowerStore 1000, 3000, 5000, 7000, and 9000 Models ● Installation and Service Guide for PowerStore 500T Model PowerStore T model initial deployment - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 8
storage services can include support for Network Attached Storage (NAS). Supported switches PowerStore can be purchased with the following Dell EMC PowerSwitch Series running OS10 Enterprise Edition (OS10EE). ● S4148F-ON ● S4148T-ON ● S5248F-ON The planning, and requirements sections of this guide - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 9
. Topics: • Initial deployment of PowerStore T model overview • Prepare to configure the Management switch and networks • Switch and network requirements for initial deployment • Configuring Dell PowerSwitch Series for Initial Deployment • Discovering PowerStore Appliances • Initial configuration of - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 10
Manager Initial Configuration Wizard. After you have completed initial deployment, PowerStore T model will be configured to support Fibre Channel Connectivity. If you want to support services such as iSCSI host connectivity, replication, import, clustering or Network Attached Storage (NAS) you - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 11
and network resources you will be using to deploy a PowerStore T model appliance see Switch and network requirements for initial deployment. If you will be configuring Top-of-Rack (ToR) switches for additional protocols and services after initial deployment, you may also want to reserve the - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 12
PowerStore, you will be guided through the Initial Configuration Wizard to create your first PowerStore cluster. For a sample of a completed Management Network Preparation Worksheet for Dell ) or Block Optimized Appliance Service Tags Enter the service tag. The service tag appears on the black - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 13
the address used to manage the cluster. VLAN (Optional, defaults to Netmask/Prefix 0) Length Gateway IP Addresses 3 IPs for each PowerStore T model appliance Infrastructure Services Record IP addresses for your DNS and NTP servers. It is recommended that you specify at least two addresses for - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 14
password provided after initial log in to the PowerStore T model appliance. For a sample of a completed Initial Configuration Worksheet for Dell PowerSwitch Series see, Get your completed Initial Configuration Worksheet. If you plan to add services, in addition to Fibre Channel connectivity, to your - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 15
IP requirements for initial deployment Management switch requirements Deployment with at least one out-of-band management switch is required for all PowerStore T model deployments. Node to Management switch The Management switch is connected through the 1 GbE management port on each of the appliance - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 16
T model, the Management switch ports must support untagged native VLAN traffic. The following diagram shows where the management ports are located on the PowerStore T model base enclosure nodes. Node A Management Port Node B Management Port Figure 2. PowerStore T model base enclosure node management - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 17
model with multiple and unique VLANs to separate the traffic. However, if only one VLAN is available, you have the option to deploy PowerStore T model with a single VLAN and multiple unique subnets as demonstrated below. The following networks must be configured on the Management switch for initial - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 18
T model networks Subnet Description Management network traffic which provides access to: ● Infrastructure services such as DNS, NTP, and SMTP. ● PowerStore REST API, PowerStore Manager, and PowerStore CLI ● SupportAssist ● VASA provider Remote discovery network is generated automatically by the - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 19
examples of the different VLAN options for initial deployment of PowerStore T model. PowerStore T - Untagged Management VLAN Management Management switch PowerStore T Sample ID 100 100 Traffic Remote Discovery PowerStore Management Untagged Traffic Tagged Traffic Subnet 169.254.x.x/16 y.y.y.y/24 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 20
requirements for initial deployment You will need IP addresses to configure the networks in PowerStore through the Initial Configuration Wizard (ICW) which runs automatically after you discover PowerStore. Management network IP address requirements You will need to reserve a total of 4 IP addresses - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 21
requirements for the Storage network during initial deployment. However, you will need IP address for the Storage networks if you are adding them later in PowerStore Manager, REST API, or CLI. See Add Storage Services. Switch and network requirements for initial deployment 21 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 22
S4148, and S5200F model switches into the PowerStore T model cabinet. Table 6. Dell PowerSwitch Series installation resources Dell EMC PowerSwitch Series Link Dell EMC PowerSwitch S4100-On Series Installation Guide dell.com/support/manuals/en-us/networking-s4128f-on,networkings4148f-on/s4100f - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 23
use a direct connection or a remote connection to discover your PowerStore. Once you have successfully discovered your PowerStore, you will be guided through the Initial Configuration Wizard to create your first PowerStore cluster. Configuring Dell PowerSwitch Series for Initial Deployment 23 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 24
base enclosure nodes, validate the configuration before discovering the PowerStore T model appliance. For validation options see: Validate the to the Dell EMC PowerSwitch S4100-ON Series Installation Guide located at: https://www.dell.com/support/home/us/en/04/product-support/product/networking- - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 25
Guide Dell EMC are available for download on Dell Digital Locker (www.dell.com/support/software/). OS10# show license status System Information Vendor Name : Dell EMC Product Name : S4148F-ON Hardware Version: A00 Platform Name : x86_64-dellemc_s4100_c2538-r0 PPID : CN00Y2VTCES0082O0038 Service - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 26
to connect to PowerStore T model: ● 2 ports for connectivity to the Management Uplink switch. ● 2 ports to connect to PowerStore T model. ● ethernet ports on the switch that will connect to the PowerStore T model management ports. interface ethernet 1/1/2 description "PowerStoreNodeA_MgmtPort" - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 27
switch Cable the Management switch to the appliance base enclosure nodes and the management uplink. Examples in this guide demonstrate deploying the PowerStore T model appliance with Dell EMC PowerSwitch S4148-ON switches. Cable the management ports on the nodes to the Management switch The - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 28
of the Management switch. Cable the Management switch to the management uplink The Management switch must also be cabled to the management uplink. 28 Configuring Dell PowerSwitch Series for Initial Deployment - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 29
switch, and cabled the switches to your PowerStore T model nodes, validate the switch configuration prior to discovering PowerStore T model. 1. Establish a terminal session Vlan Tagged-Vlans A 100 - A 100 - - - A 100 - Configuring Dell PowerSwitch Series for Initial Deployment 29 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 30
/1/53 Dell EMC PowerStore 00:60:16:9e:e6:2c cyc-coreos mgmt1/1/1 MGMT-01 ethernet1/1/41 68:4f:64:68:c7:1d 6. Review the support account to download the NVT. You can create an account from www.dell.com/support. Once you have downloaded the NVT, see the Network Validation Tool for PowerStore - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 31
correctly configured. The NVT can be downloaded from Dell EMC Central Solutions at https://psapps.emc.com/central/solutions. ● Ensure that your workstation's Network adapter is configured as follows: ○ Connected directly to the PowerStore service port on node A. ○ Configured with a static IP address - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 32
downloaded from Dell EMC Central Solutions at https://psapps.emc.com/central/solution/ NVT-PowerStore. ● or antivirus services. 1. From your workstation or virtual machine, launch the PowerStore Discovery Utility. You can discover PowerStore systems remotely using a static IP. Review the following - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 33
to validate that your networks are correctly configured. The NVT can be downloaded from Dell EMC Central Solutions at https://psapps.emc.com/central/solution/ NVT-PowerStore. ● Ensure that your workstation or virtual machine is connected directly to the same switch that the base enclosure is - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 34
Block-optimized for Fibre Channel only deployments and to add services after initial configuration such as iSCSI host connectivity, replication, clustering and import. ● Management network If you want to use the native VLAN for any of your PowerStore networks, you must enter VLAN ID 0 (zero) for any - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 35
see PowerStore Virtualization Infrastructure Guide. Get your completed Initial Configuration Worksheet You should have worked with your network administrator to complete the Initial Configuration Worksheet. The following worksheet has been completed with the resources configured on the on the Dell - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 36
. 192.168.1.10 VLAN (Optional, defaults to 0) Netmask/Prefix Length Gateway IP Addresses 3 IPs for each PowerStore T model appliance 0 255.255.255.0/24 192.168.1.1 192.168.1.11-13 Infrastructure Services Record IP addresses for your DNS and NTP servers. It is recommended that you specify at - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 37
Table 12. Initial Configuration Worksheet (completed) (continued) Password This is the user-defined password provided N/A after initial log in to the PowerStore T model appliance. Initial configuration of the PowerStore T model appliance 37 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 38
and network requirements for deployments with ToR switches • Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-of-Rack switches • Cable Dell PowerSwitch Series ToR switches for Storage services • Validate PowerSwitch Series configuration with ToR switches • Configure Storage - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 39
To add Storage services you must connect the PowerStore T model appliance to two Top-of-Rack (ToR) switches. This document describes the steps to deploy PowerStore T model with a single cluster consisting of one appliance with a single base enclosure connected to Dell PowerSwitch Series S4148 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 40
services. For a sample of a Switch Resources for Storage services Worksheet completed for Dell PowerSwitch Series see, Completed example of Switch Resources for Storage services create the Storage networks in PowerStore Manager. Table 13. Switch Resources for Storage services (blank) Step Step - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 41
services (blank) (continued) Step Step details Notes 4. Reserve and record the IP addresses necessary to configure the ToR switches below: Management IP address for ToR Switch 1 Management IP address for ToR Switch 2 Default gateway NTP server 5. Dell EMC supports deploying PowerStore - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 42
Table 13. Switch Resources for Storage services (blank) (continued) Step Step details Notes 11. As a best practice You will need to reserve the following resources to create Storage networks in PowerStore Manager. Work with your network administrator to complete the Storage Network Configuration - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 43
services Top-of-Rack (ToR) switch connectivity options and requirements In addition to the Management switch configured during your initial deployment of the PowerStore T model appliance, you must add two ToR switches to support 1. Multi-chassis Link Dell highly recommends using MC-LAG - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 44
of Rack Switch 2 Port 0 Port 1 Node A Port 1 Port 0 Node B PowerStore T Appliance Legend: 10 Gb 1 Gb Figure 10. ToR switches with MC-LAG interconnect Vendor specific MC-LAG technology Vendor Proprietary MC-LAG technology Dell Virtual Link Trunking (VLT) Cisco Virtual PortChannel (vPC) - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 45
speed ports are located on your switch. ● Use two cables that support connectivity between the high speed ports. For example 100Gbps Direct Attached Cables connect the ToR switches is an acceptable alternative to MC-LAG for PowerStore deployments. With a non-MC-LAG L2 connection you can port-channel - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 46
interconnect Upstream Switch 1 Upstream Switch 2 Port Channels Top of Rack Switch 1 Top of Rack Switch 2 Port 0 Port 1 Node A Port 1 Port 0 Node B PowerStore T Appliance Legend: 10 Gb 1 Gb Figure 11. ToR switches with a non-MC-LAG L2 interconnect NOTE: Port location for the reliable - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 47
and Port 1 on Node B must connect to opposite switches Network configuration when adding Storage services All of the Storage, NAS Server, and Internal traffic is routed through the Top-of-Rack (ToR) switches. PowerStore T model requires all networks to be unique. It is highly recommended to deploy - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 48
is being routed properly for all networks that PowerStore T model is utilizing. Table 17. PowerStore T model networks when adding Storage services Subnet Description Node transport ports Storage network (block) traffic including PowerStore T model model ISCSI target portals for front-end - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 49
with IPSEC. ● For intra-cluster data mobility traffic such as storage migration between appliances. ● To enable file services on an Unified appliance, communication will be routed within the PowerStore T model appliance rather than the ToR switch. First 2 ports of the 4-port card (LACP bond) While - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 50
VLANs if you are running multiple NAS servers. Storage network IP address requirements for adding Storage services You will need to reserve IP addresses to add one or more Storage network to your PowerStore T model appliance. You will need to reserve a total of 3 IP address for each Storage network - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 51
Table 18. Storage network IP address requirements IP Addresses per Assigned to Appliance Node A iSCSI Target Node B iSCSI Target Cluster Global Storage Discovery IP Address (iptional) Number of IP Addresses required 1 1 1 You can choose to assign either IPv4 or IPv6 addresses to the storage - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 52
S4148, and S5200F model switches into the PowerStore T model cabinet. Table 19. Dell PowerSwitch Series installation resources Dell EMC PowerSwitch Series Dell EMC PowerSwitch S4100-On Series Installation Guide Link dell.com/support/manuals/en-us/networking-s4128f-on,networkings4148f-on/s4100f - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 53
the switches into the cabinet. Configure Dell PowerSwitch Series for Storage services At a minimum you will need to configure one out-of-band (OOB) management switch, and two Top-of-Rack (ToR) switches for PowerStore T model to support iSCSI host connectivity, replication, import, clustering - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 54
Table 20. Switch resources for Storage services worksheet (completed) (continued) Step Step details Notes Node A, Port 1 to .0.100.11/24 Default gateway 100.0.100.1 NTP server 100.0.100.200 5. Dell EMC supports deploying PowerStore T model with two Top-of-Rack (ToR) switches with a layer 2 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 55
Switch resources for Storage services worksheet (completed) (continued the Dell EMC PowerSwitch S4100-ON Series Installation Guide located at: https://www.dell.com/support/home/us/en/04/product-support/ None Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-of-Rack switches 55 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 56
Guide Dell EMC are available for download on Dell Digital Locker (www.dell.com/support/software/). OS10# show license status System Information Vendor Name : Dell EMC Product Name : S4148F-ON Hardware Version: A00 Platform Name : x86_64-dellemc_s4100_c2538-r0 PPID : CN00Y2VTCES0082O0038 Service - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 57
Protocol) is enabled globally on each interface by default. You can use LLDP for troubleshooting and validation. It is recommended that you enable all of the optional TLVs (type terminal hostname Switch2 Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-of-Rack switches 57 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 58
details. VLTi is required to configure Link Aggregation Control Protocol between the PowerStore nodes. 1. Establish a terminal connection to the first ToR switch (Switch1 described in this guide. peer-routing 58 Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-of-Rack switches - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 59
peer-routing primary-priority 8192 vlt-mac 00:00:00:00:00:01 Configure PowerStore T model Native VLAN on the Top-of-Rack switches NOTE: Remote Discovery, vlan 1 description Internal_Network no shutdown exit Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-of-Rack switches 59 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 60
shutdown switchport mode trunk switchport access vlan 1 8. Configure the ports that are connected to PowerStore T model nodes as spanning tree protocol (STP) edge ports. spanning-tree port type LACP mode. 60 Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-of-Rack switches - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 61
). 2. Enter global configuration mode. configure terminal 3. Configure the port-channel for the uplinks. interface port-channel 30 description Uplink no shutdown switchport mode trunk Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-of-Rack switches 61 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 62
to your completed Network Preparation Worksheet for Storage services, for a list of VLAN IDs you should have reserved prior to this step. 1. Establish a terminal connection to the first ToR switch (Switch1). 62 Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-of-Rack switches - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 63
Optionally, configure Top-of-Rack switches to support NAS networks Network Attached Storage is only supported with Unified deployments. 1. Establish a terminal connection to the first ToR switch (Switch1). Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-of-Rack switches 63 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 64
switchport trunk allowed 300 exit interface port-channel 20 switchport trunk allowed 300 exit interface port-channel 30 switchport trunk allowed 300 exit 64 Configuring PowerStore T model with Dell PowerSwitch Series S4148 Top-of-Rack switches - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 65
12 Cable Dell PowerSwitch Series ToR switches for Storage services This chapter contains the following information. Topics: • Cable the base enclosure to the 4 Connect Port 0 of the top node (B), to Port 54 of the top switch (2). Cable Dell PowerSwitch Series ToR switches for Storage services 65 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 66
PowerStore dual switch deployments with VLT, requires that the two Top of Rack (ToR) switches are cabled together. 1 2 Figure 16. Switch-to-switch connectivity Use two cables that support to 100 GbE port 26 of the top switch (2). 66 Cable Dell PowerSwitch Series ToR switches for Storage services - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 67
-ON ToR switch connections to the core uplinks Table 28. Steps to connect to the Dell EMC PowerSwitch Series S4148-ON ToR switches to the core uplinks 1 Connect port 30 of the uplink ports to which the ToR switches will connect. Cable Dell PowerSwitch Series ToR switches for Storage services 67 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 68
. Topics: • Validate configuration on the Top-of-Rack (ToR) switches • Network Validation Tool after adding the Top-of-Rack switches to your PowerStore T model deployment Validate configuration on the Top-of-Rack (ToR) switches Once you have configured and cabled your ToR switches, validate the - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 69
Advertised 00:e0:ec:da:e4:f2 00:e0:ec:da:e4:f2 ethernet1/1/1 Dell EMC PowerStore 00:e0:ec:da:e4:e2 cyc-coreos ethernet1/1/25 Switch2 ethernet1/1/25 e4 00:e0:ec:da:84:4f 00:e0:ec:da:84:4f ethernet1/1/54 Dell EMC PowerStore 00:e0:ec:da:84:3f cyc-coreos mgmt1/1/1 MGMT-01 ethernet1/1/42 68 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 70
2 2 10. Repeat steps on ToR switch 2. 11. Review the running configuration for ToR switch 1, and repeat on ToR PowerStore T model appliance Storage services. The NVT is available for download from Dell EMC Central Solutions (https://psapps.emc.com/central/solutions). You must have an online support - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 71
Network Attached Storage (NAS) services in PowerStore Manager Create iSCSI storage networks in PowerStore Manager Once you have configured the ToR switches for Storage services, you will need to create Storage Networks for iSCSI support in PowerStore Manager. PowerStore supports up to 32 Storage - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 72
Create Network Attached Storage (NAS) services in PowerStore Manager NAS services are enabled when you select Unified mode in the PowerStore Manager Initial Configuration Wizard. Once you have configured PowerStore Manager, the networks are created in PowerStore Manager when you create NAS servers - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 73
an example of cabling port 2 of the 4-port card to two Dell PowerSwitch Series S4148 Top-of-Rack (ToR) switches. To use these instructions, a storage network, and the ToR switches must have been configured as described in Add Storage Services. The following example uses port 2 of the 4-port card - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 74
Configure the VLAN on the ToR switches The following steps provide an example of configuring VLANs on two Dell PowerSwitch Series S4148 Top-of-Rack (ToR) switches. You can cable the PowerStore T model appliance nodes to the switches before or after you perform these steps. For steps, see Cable the - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 75
automatically maps the unused IP addresses you added in Step 5. 11. Select Map Network again in the Map Storage Network confirmation dialog box. PowerStore Manager will automatically map the Storage network to both the port you selected, and the corresponding port on the other node. 12. To validate - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 76
in Add Storage Services. If you did not use the same Dell EMC PowerSwitch Series S4148 ToR switches described in this guide, then replace configure an additional port on which to create a new Storage network on the PowerStore T model appliance. 1. Cable the nodes to the ToR switches. 2. Configure a - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 77
Dell PowerSwitch Series S4148 Top-of-Rack (ToR) switches. To use these instructions, a storage network, and the ToR switches must have been configured as described in Add Storage Services network on two Dell PowerSwitch Series S4148 Top-of-Rack (ToR) switches. You can cable the PowerStore T model - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 78
for sample values. 4. Select the checkbox next to the name of the first port over which the storage traffic will run for the Storage network. PowerStore Manager will automatically map the Storage network to both the port you selected, and the corresponding port on the other node. 5. To validate the - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 79
are the steps required to deploy PowerStore T model with two Top-or-Rack switches without a Virtual Link Trunking interconnect. Specific code sample for the following steps for configuring PowerSwitch Series are available in Configuring Dell PowerSwitch Series for deployments with ToR switches - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 80
Architecture Guide https://infohub.delltechnologies.com/l/dell-emc-smartfabricservices-with-dell-emc-powerstore-reference-architectureguide-1/deploying-powerstore-with-smartfabric-services PowerStore: Configuring SmartFabric for a PowerStore environment https://www.dell.com/support/kbdoc - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 81
used in PowerStore T model deployments Use the following command to generate a running configuration file when Dell PowerSwitch Series S4148 19 04:19:20 2020 ! snmp-server contact http://www.dell.com/support hostname powerstoreMgmtSwitch interface breakout 1/1/25 map 100g-1x interface breakout 1/1/ - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 82
shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/15 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! 82 Other Dell EMC PowerSwitch Series configuration operations - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 83
Uplink no shutdown channel-group 10 mode active no switchport flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/29 no shutdown switchport access vlan 1 Other Dell EMC PowerSwitch Series configuration operations 83 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 84
! interface ethernet1/1/40 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/41 shutdown switchport access vlan 1 flowcontrol receive off 84 Other Dell EMC PowerSwitch Series configuration operations - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 85
shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/53 description PowerStoreNodeB_MgmtPort no shutdown switchport access vlan 100 flowcontrol receive off Other Dell EMC PowerSwitch Series configuration operations 85 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 86
mode trunk switchport access vlan 1 ! Version 10.4.1.4 ! Last configuration change at Mar 19 04:24:55 2020 ! snmp-server contact http://www.dell.com/ support hostname Switch1 interface breakout 1/1/25 map 100g-1x interface breakout 1/1/26 map 100g-1x interface breakout 1/1/29 map 100g-1x interface - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 87
access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/10 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/11 Other Dell EMC PowerSwitch Series configuration operations 87 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 88
flowcontrol transmit off ! interface ethernet1/1/21 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/22 shutdown switchport access vlan 1 88 Other Dell EMC PowerSwitch Series configuration operations - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 89
/1/33 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/34 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off Other Dell EMC PowerSwitch Series configuration operations 89 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 90
vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/45 shutdown switchport access vlan 1 flowcontrol receive off flowcontrol transmit off ! interface ethernet1/1/46 90 Other Dell EMC PowerSwitch Series configuration operations - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 91
10/24 ipv6 address autoconfig ! management route 0.0.0.0/0 100.0.100.1 ! support-assist ! vlt-domain 1 backup destination 100.0.100.11 shutdown switchport ! management route 0.0.0.0/0 100.0.100.1 ! support-assist ! vlt-domain 1 Other Dell EMC PowerSwitch Series configuration operations 91 - Dell PowerStore 500T | EMC PowerStore Networking Guide for PowerStore T Models - Page 92
:01 backup destination 100.0.100.10 discovery-interface ethernet1/1/25-1/1/26 peer-routing primary-priority 1 vlt-mac 00:00:00:00:00:01 92 Other Dell EMC PowerSwitch Series configuration operations
Dell EMC PowerStore
Networking Guide for PowerStore T Models
Version 2.x
June 2021
Rev. A01