Dell N3200-ON PowerSwitch N3200-ON/E3200-ON Series Installation Guide
Dell N3200-ON Manual
View all Dell N3200-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Dell N3200-ON manual content summary:
- Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 1
Dell PowerSwitch N3200-ON/E3200-ON Series Installation Guide May 2023 Rev. A12 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 2
data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2020 - 2023 Dell Inc. or its subsidiaries. All rights reserved. Dell Technologies, Dell, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 3
Chapter 1: About this guide...6 Related documents...7 Information symbols...7 Chapter 2: N3200-ON/E3200-ON Series switch 8 Introduction...8 Features...13 Physical dimensions...14 LED display...14 LED behavior...14 Prerequisites...18 N3200-ON/E3200-ON Series switch configurations 18 Luggage tag - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 4
9: Installation using ONIE 74 Before you install an operating system...74 Check your switch...75 Uninstall an existing OS...75 Install a NOS...76 Automatic NOS installation...76 Manual NOS installation...77 Chapter 10: Specifications...79 Chassis physical design...79 PoE Budget Specifications - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 5
Electromagnetic compatibility ...86 Product recycling and disposal...87 Chapter 11: Dell support...88 Contents 5 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 6
About this guide This guide provides site preparation recommendations, step-by-step procedures for rack mounting and desk mounting your switch, inserting guide before you install and power on this equipment. This equipment contains two power cables. Disconnect both power cables before servicing. - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 7
the Dell PowerSwitch N2200-ON and N3200-ON/E3200-ON Series Switches ● N3248TE-ON only: Enterprise SONiC Distribution by Dell Technologies User Guide ● N3248TE-ON only: Release Notes for Enterprise SONiC Distribution by Dell Technologies÷ NOTE: For the most recent documentation, see Dell support: www - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 8
-ON/E3200-ON Series switch The following sections describe the Dell N3200-ON/E3200-ON Series (N3208PX-ON, N3224T-ON, N3224F-ON/E3224FON, N3224P-ON, N3224PX-ON, N3248TE-ON, N3248P-ON/E3248P-ON, N3248X-ON, and N3248PXE-ON/E3248PXE-ON) switches: Topics: • Introduction • Features • Physical dimensions - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 9
Table 1. N3200-ON/E3200-ON Series switch summary (continued) Marketing model name (MMN) Description ● Two ports 100G QSFP28 stacking N3248TE-ON ● 48 ports -T RJ45 with 802.3bt Type-4 (90 W) PoE 4. RJ45 serial management port 6. USB Type-A port 8. Status LEDs N3200-ON/E3200-ON Series switch 9 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 10
Ethernet console port 6. Stack ID 8. Status LEDs 1. Luggage tag 3. RJ45 serial management port 5. USB Type-A port 7. Micro-USB Type-B port 9. 10G SFP+ ports 10 N3200-ON/E3200-ON Series switch 2. 1GBASE-T RJ45 with 802.3at Type-2 (30 W) PoE 4. RJ45 Ethernet console port 6. Stack ID 8. Status LEDs - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 11
8. Status LEDs 1. Luggage tag 3. RJ45 serial management port 5. USB Type-A port 2. 1GBASE-T RJ45 with 802.3at Type-2 (30 W) PoE 4. RJ45 Ethernet console port 6. Stack ID N3200-ON/E3200-ON Series switch 11 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 12
management port 5. USB Type-A port 7. Micro-USB Type-B port 9. 10G SFP28 ports N3200-ON/E3200-ON Series PSU-side views: N3208PX-ON PSU-side view 2. 10GBASE-T RJ45 with 802.3bt Type-4 (90 W) PoE 4. RJ45 Ethernet console port 6. Stack ID 8. Status LEDs 1. Fan 12 N3200-ON/E3200-ON Series switch - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 13
-ON, N3248PXE-ON/E3248PXE-ON PSU-side view 1. 100G QSFP28 stacking ports 3. EPS connections 2. Fans 4. AC or DC PSUs Features The N3200-ON/E3200-ON Series switch offers the following features: ● Ports: ○ N3208PX-ON-Compact, four ports 1GBASE-T RJ45 with 802.3bt Type-4 90W PoE, four ports 5GBASE - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 14
the PSU and fan tray handle: ● N3208PX-ON: ○ 43.5 mm x 279.4 mm x 312 mm (H x W x D) ○ 1.71 in x 11 in x 12.28 in (H x W x D) ● All N3200-ON/E3200-ON Series switches except the N3208PX-ON: ○ 43.5 mm x 434 mm x 400 mm (H x W x D) ○ 1.71 in x 17.09 in x 15.75 in (H x W x D) (PSU and fan tray handle - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 15
-management port on the right side 4. Stack ID LED 6. System Status/health LED 8. Fan LED 10. Stacking port activity LEDs Table 2. N3200-ON/E3200-ON Series switch LED behavior LED Description 7-Segment LED for stacking ● Off-No power ● Solid green-Hex digit representing the stack unit ID Stack - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 16
Table 2. N3200-ON/E3200-ON Series switch LED behavior (continued) LED Description ● Solid yellow-Critical system error; major fault ● Flashing yellow-Noncritical system error ● Off-No activity and PoE power off ● Solid yellow-No port activity and PoE power on 16 N3200-ON/E3200-ON Series switch - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 17
green, ~30ms-port activity at maximum speed, 100G ● Flashing yellow, ~30ms-port activity at speed less than 100G ● Flashing yellow, 1 second on/off-port beacon N3200-ON/E3200-ON Series switch 17 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 18
is a list of components that are required for successful switch installation: NOTE: For detailed installation instructions, see Site preparations and N3200-ON/E3200-ON Series switch installation. ● N3200-ON/E3200-ON Series switch or multiple switches, if stacking ● AC or DC country- and regional - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 19
N3208PX-ON, N3224F-ON/E3224F-ON, N3224P-ON, N3224PX-ON, and N3224T-ON luggage tag 1. Product ID QRL 3. Service tag 5. Express service code 2. Product information QRL 4. MAC address N3248P-ON/E3248P-ON, N3248PXE-ON/E3248PXE-ON, N3248TE-ON, N3248X-ON luggage tag N3200-ON/E3200-ON Series switch 19 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 20
1. Product ID QRL 3. Service tag 5. Express service code 2. Product information QRL 4. MAC address N3200-ON/E3200-ON series reset button The reset button is accessed through the pinhole on the upper right-hand corner on the I/O-side of the switch, and enables performing a hard reset. To reset the - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 21
complete clean request. The operating system performs a complete reset of any user configured parameters and sets a reset bit for the CPLD to perform a cold reboot. N3200-ON/E3200-ON Series switch 21 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 22
Site selection Install the switch equipment in restricted access areas. A restricted access area is one in which service personnel can only gain information about switch storage and environmental temperatures, see Specifications. Cabinet placement Install the N3200-ON/E3200-ON Series switch only in - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 23
service in your area uses. The ground path must be permanent. Switch ground Dell Technologies recommends you ground your switch. Use the N3200-ON/E3200-ON Series switch stock keeping unit (SKU) type. The N3200-ON/E3200-ON Series switch has SKUs that support the following configurations: ● AC or DC - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 24
the module power. You do not see module LEDs when the switch powers up in ONIE. Storing components If you do not install your N3200-ON/E3200-ON Series switch and components immediately, properly store the switch and all components using these guidelines: ● Storage location temperature must remain - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 25
an ESD-preventive wrist or heel ground strap when handling the N3200-ON/E3200-ON Series switch and components. As with all electrical devices of this type, : This document is a condensed reference. Read the safety instructions in your Safety, Environmental, and Regulatory information booklet before - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 26
not a suitable grounding point. Desktop One mounting option is to place the N3200-ON/E3200-ON Series switch on a desktop. The mounting supplies for this installation ship with the switch. 1. Locate the four rubber feet shipped with the switch. 2. Remove the paper backing on the bottom of one of the - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 27
only. NOTE: Do not use this installation procedure for the full-width N3200-ON/E3200-ON Series switches. The mounting supplies for this installation ship with the switch. To complete this installation, you need a pencil, drill, and Phillips-head drill bit. 1. Locate the ceiling mount tray, ceiling - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 28
only. NOTE: Do not use this installation procedure for the full-width N3200-ON/E3200-ON Series switches. The mounting supplies for this installation ship with the switch. To complete this installation, you need a pencil, drill, and Phillips-head drill bit. 1. Locate the wall mount tray, wall anchors - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 29
6. Slide the switch into the wall mount tray. 7. Line up the two mushroom-heads on the switch to the wall mount tray hook cutouts until the switch locks into place. 8. Fix the switch to the wall mount tray using two screws on each side. N3200-ON/E3200-ON Series switch installation 29 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 30
Use the DIN buckle with wall- or ceiling-mount installations. This switch installation procedure applies to the compact N3208PXON switch only. NOTE: Do not use this installation procedure for the full-width N3200-ON/E3200-ON Series switches. This installation requires both the DIN rail mount kit and - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 31
. Use these brackets for front- or center-mount installation. NOTE: Do not use this installation procedure for the full-width N3200-ON/E3200-ON Series switches. You must order the mounting supplies for this installation separately. For a front-mount installation, align the standard bracket rackmount - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 32
supply, see the External Power Supply (EPS) Installation for the Dell PowerSwitch N2200-ON and N3200-ON/ E3200-ON Series Switches at www.dell.com/support. The mounting supplies for this installation ship with the switch. 1. Locate the mounting brackets and screws. 2. Insert the mounting brackets - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 33
supply, see the External Power Supply (EPS) Installation for the Dell PowerSwitch N2200-ON and N3200-ON/ E3200-ON Series Switches at www.dell.com/support. The mounting supplies for this installation ship with the switch. 1. Locate the mounting brackets and screws. 2. Insert the mounting brackets - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 34
install an external power supply, see the External Power Supply (EPS) Installation for the Dell PowerSwitch N2200-ON and N3200-ON/ E3200-ON Series Switches at www.dell.com/support. NOTE: Do not wall mount the switch with the I/O ports facing up or down. You must order the mounting supplies for this - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 35
- or ceiling-mount dimensions 5. Drill eight 8 mm (0.3 in) holes in the wall or ceiling at the pencil marks. 6. Install the eight anchors into the holes. N3200-ON/E3200-ON Series switch installation 35 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 36
the switch onto the screws and tighten the screws to secure the switch in place. Torque the screws to 24 in-lbs. Wall mount 9. Screw the remaining four M5 screws into the anchors and tighten the screws. Torque the screws to 24 in-lbs. Wall mount 36 N3200-ON/E3200-ON Series switch installation - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 37
ceiling mount One RU ReadyRails installation Install the N3200-ON/E3200-ON Series switch, excluding the N3208PX-ON switch, using one of the following installation instructions. You can install the ReadyRails system using the 1U tool-less square-hole method or one of three possible 1U threaded round - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 38
Tool-less mount ReadyRails installation This switch installation procedure is for the full-width N3200-ON/E3200-ON Series switches only. NOTE: Do not use this installation procedure for the compact N3208PX-ON switch. NOTE: For more installation instructions, see the installation labels attached to - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 39
rail. Flush-mount ReadyRail installation This switch installation procedure is for the full-width N3200-ON/E3200-ON Series switches only. NOTE: Do not use this installation procedure for the compact N3208PX-ON switch. NOTE: For more installation instructions, see the installation labels attached to - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 40
rail. Center-mount ReadyRail installation This switch installation procedure is for the full-width N3200-ON/E3200-ON Series switches only. NOTE: Do not use this installation procedure for the compact N3208PX-ON switch. NOTE: For more installation instructions, see the installation labels attached to - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 41
rail. Threaded ReadyRails installation This switch installation procedure is for the full-width N3200-ON/E3200-ON Series switches only. NOTE: Do not use this installation procedure for the compact N3208PX-ON switch. NOTE: For more installation instructions, see the installation labels attached - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 42
optics, see the specification sheets at www.dell.com/support or contact your Dell Sales representative. CAUTION: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the N3200-ON/E3200-ON Series switch and components. WARNING: When - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 43
or heel ground strap when handling the N3200-ON/E3200-ON Series switch and components. After switch placement After you have securely installed and powered on the N3200-ON/E3200-ON Series switch: ● For switch documentation and resources, see https://www.dell.com/support. ● For ONIE documentation and - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 44
11. Copy the backed-up switch configuration to the new switch. copy tftp://hostip/filepath running-config NOTE: For firmware update procedures, see the most current switch-specific release notes at www.dell.com/support, Drivers and Downloads section. 44 N3200-ON/E3200-ON Series switch installation - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 45
describes how to attach the power adapter holder assembly to the switch. This EPA installation instruction procedure applies to the N3208PX-ON switch only. NOTE: Do not use this installation procedure for the full-width N3200-ON/E3200-ON Series switches. You can use one or two EPAs with your adapter - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 46
the EPA cable. Wall or ceiling installation To install a single EPA power adapter holder on a wall or ceiling: NOTE: This installation instruction procedure applies to the external power adapter. You must order the mounting supplies for this installation separately. You need a drill and a pencil - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 47
Wall mount 5. Install the AC power cable to the EPA and secure with the wire clip. 6. Bend the AC power cable 180 degrees along the holder wall and through the cable cutout. External power adapter 47 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 48
DIN rail installation To install an external power adapter to DIN rails: NOTE: This installation instruction procedure applies to the external power adapter only. You must order the mounting supplies for this installation separately. 1. Remove the two DIN buckles and screws - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 49
EPA power adapter holder on the side of your switch in a four-post rack: NOTE: This installation instruction procedure applies to the N3208PX-ON switch only. 1. Install the single EPA in the power adapter holder using the instructions in Power adapter holder assembly. 2. Align the two mushroom - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 50
. Slide the power adapter holder forward to lock it in place. 3. Use two screws to secure the power adapter holder to the side of the switch. 4. Install the AC power cable to the EPA and secure with the wire clip. 5. Bend the AC power cable 180 degrees along the holder wall - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 51
only. 1. Install the single EPA in the power adapter holder using the instructions in Power adapter holder assembly. 2. Align the two mushroom heads on the switch with the two holes on the power adapter holder. Slide the power adapter holder forward to lock it in place. 3. Use two screws to secure - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 52
Dual-EPAs two-post front-mount installation To install two EPA power adapter holders in a front-mount two-post rack: NOTE: This installation instruction procedure applies to the N3208PX-ON switch only. NOTE: For this installation, you need two-rack units of space in your mounting rack. Install the - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 53
wire clip. 8. Bend the AC power cable 180 degrees along the holder wall and through the cable cutout. 9. Install the dual-EPA assembly above the switch in the two-post rack. For rack installation instructions, see N3200-ON/E3200-ON Series switch installation. External power adapter 53 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 54
Dual-EPAs two-post center-mount installation To install two EPA power adapter holders in a center-mount two-post rack: NOTE: This installation instruction procedure applies to the N3208PX-ON switch only. NOTE: For this installation, you need two-rack units of space in your mounting rack. Install the - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 55
wire clip. 8. Bend the AC power cable 180 degrees along the holder wall and through the cable cutout. 9. Install the dual-EPA assembly above the switch in the two-post rack. For rack installation instructions, see N3200-ON/E3200-ON Series switch installation. External power adapter 55 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 56
56 External power adapter - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 57
on your requirement. To install an external power supply, see the External Power Supply (EPS) Installation for the Dell PowerSwitch N2200-ON and N3200-ON/E3200-ON Series Switches at www.dell.com/support. Table 11. AC PSU input voltage AC PSU Input voltage Output DPS-320AP (For N3208PX-ON only - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 58
supply with integrated fan ● AC or DC power supply with integrated reverse-flow fan NOTE: Reserve airflow is only supported on the N3224T-ON, N3248TE-ON, and N3248X-ON switches. For the N3200-ON/E3200-ON Series switches, power supply 1 (PSU1) and power supply 2 (PSU2) are on the right side of the - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 59
. When you install the PSU correctly, the power connector is on the right side of the PSU. 1. Remove the PSU slot cover from the N3200-ON/E3200-ON Series switch using a small #1 Phillips screwdriver. The PSU slot cover has two screws on the top and two screws on the bottom of the platform - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 60
as this action may damage the PSU or the N3200-ON/E3200-ON Series switch. NOTE: If a PSU fails, you must replace the entire unit. There are no field serviceable components in the PSU. To request a hardware replacement, see www.dell.com/support/. 1. Disconnect the power cable from the PSU. 2. Use the - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 61
5000 m. The product must be supplied by a UL-Listed DC power source that is separated from AC mains by double or reinforced insulation when the switch is connected to 1300W DC power. For more information, contact your - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 62
be smaller than the conductors supplying power. Secure all screws and ground-wire connections. NOTE: Dell Technologies recommends using a 40 A circuit breaker. Before you supply 1300W DC current to the switch, review the current rating of your protective device. NOTE: You need a user-supplied flat - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 63
information about the external power supply, see External Power Supply (EPS) Installation for the Dell PowerSwitch N2200-ON and N3200-ON/E3200-ON Series Switches at www.dell.com/support. NOTE: The EPS power cable supports a maximum of 2400 W. If you require more power than 2400 W, you must connect - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 64
NOTE: If you are connecting a single EPS power cable to your switch, always use primary A-slot. Leave the secondary B-slot DC power cover in place, as shown: 2. Unscrew the DC-power-OUT cover from the rear of - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 65
3. Connect the EPS power cable to the EPS-DC-In on the switch. Torque the screw to 10 in-lbs. One EPS power cable connected Two EPS power cables connected 4. Connect the other end of the DC cable to either a MPS-1S shelf or MPS-3S shelf. Power supply 65 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 66
Torque the screw to 10 in-lbs. One EPS power cable connected to a MPS-1S shelf. One EPS power cable connected to a MPS-3S shelf Two EPS power cables connected to a MPS-3S shelf 66 Power supply - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 67
5. Repeat until all EPS power cables are connected. To disconnect an EPS power cable, unscrew the cable and disconnect the cable from the switch. Power supply 67 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 68
-ON, and N3248PXE-ON/E3248PXE-ON-three pluggable fans The N3200-ON/E3200-ON Series switch supports two airflow direction options. Do not mix airflow types in a switch. You can use only a single airflow direction in a switch. If the airflow directions are mismatched, you must correct the mismatched - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 69
state. ● Off-Fan is off. Fan module installation The fan module in the N3200-ON/E3200-ON Series switch, excluding N3208X-ON, is field replaceable. 1. Remove the fan slot cover from the N3200-ON/E3200-ON Series switch using a small #1 Phillips screwdriver. The fan slot cover has one screw on the - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 70
Fan module replacement To request a hardware replacement, see www.dell.com/support/. 1. Take the replacement fan module out of the shipping box. 2. Slide the installed fan module out of the bay. 3. Slide the replacement module into the bay. 70 Fans - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 71
port access • MicroUSB Type-B console port access • USB storage mount RJ45 console port access For the N3200-ON/E3200-ON Series switch, the management ports are on the I/O-side of the switch. N3208PX-ON management ports 1. Out-of-band management port (right), RJ45 console port (left) N3224F-ON - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 72
(left) NOTE: Ensure that any equipment that is attached to the serial port can support the required 115200-baud rate. NOTE: If the serial port of your system cannot console port is on the I/O side of the switch. NOTE: The N3200-ON/E3200-ON Series switches use the Silicon Labs CP2102 USB-B chip. To - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 73
port, contact Dell technical support for assistance. 1. Start up the computer. 2. Connect the USB Type-A end of cable into an available USB port on the computer. 3. Connect the microUSB Type-B end of cable into the microUSB Type-B console port on the switch. 4. Start up the switch. 5. Install the - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 74
Drivers and Downloads page for your switch at www.dell.com/support. Topics: • Before you install an operating system • Check your switch • Uninstall an existing OS • Install a NOS Before you install an operating system After powering on the N3200-ON/E3200-ON Series switch, it goes through a power-on - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 75
, see the Open Networking Hardware Diagnostic Guide for N2200-ON and N3200-ON/E3200ON Series Switches at www.dell.com/support. NOTE: After you have securely installed and powered on the N3200-ON/E3200-ON Series switch, to configure your switch, see your third-party ONIE-compatible operating - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 76
the Console port and the Management port, see the platform-specific Installation Guide at www.dell.com/support. Install the NOS For an ONIE-enabled switch, go to the ONIE boot menu. An ONIE-enabled switch boots with preloaded diagnostics (DIAGs) and ONIE software. |*ONIE: Install OS | | ONIE - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 77
Hardware Diagnostic Guide on the Dell Support site. interface ONIE: Starting ONIE Service Discovery Info: Fetching tftp:// -installer Press or to enter setup. Welcome to GRUB! Manual NOS installation If . 2. Power up the switch and select ONIE Rescue for manual installation. 3. (optional) - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 78
After the installation process completes, the switch automatically reboots into the new OS. Install manually using a USB drive You can manually install the NOS software image using a USB device. Verify that the USB device supports a FAT or EXT2 file system. For instructions to format a USB device in - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 79
10 Specifications This section lists the N3200-ON/E3200-ON Series switch specifications. CAUTION: Operate the product at an ambient temperature not higher than 45°C (113°F). NOTE: For RoHS information, see Restricted Material Compliance. Topics: • Chassis physical - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 80
.26 W = 383.05 BTU/Hr ● N3248PXE-ON/E3248PXE-ON: 325.72 W = 1111.40 BTU/Hr 10,000 feet (3,048 m) 39,370 feet (12,000 meters) Dell Spec SV0115 Specifications ● AC: 100-240 VAC 50/60 Hz ● DC: -40 VDC to -60 VDC ● N3208PX-ON: 1.12 Amps @ 110 VAC and 0.56 Amps @ 220 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 81
Ports with 802.3at Type-2 (30W) PoE ● N3248PXE-ON/E3248PXE-ON: 48x10GBase-T Ports with 802.3bt Type-4 (90W) PoE NOTE: 802.3bt Type-4 can support a minimum of 90 W and a maximum of 99.99 W at PSE output. Table 16. AC power requirements Parameter Power supply Maximum current draw per system Maximum - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 82
PoE power reduces if you connect the MPS-3S shelf to more than one PoE switch. N3248P-ON/E3248P-ON Max PoE power: ● One internal PSU: 813 W maximum PoE power reduces if you connect the MPS-3S shelf to more than one PoE switch. N3248PXE-ON/E3248PXE-ON Max PoE power: ● One internal PSU: 1056 W ● Two - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 83
PoE power reduces if you connect the MPS-3S shelf to more than one PoE switch. PoE load condition-low-line AC input N3208PX-ON Max PoE power: ● One PoE power reduces if you connect the MPS-3S shelf to more than one PoE switch. N3248PXE-ON/E3248PXE-ON Max PoE power: ● One internal PSU: 406 W ● - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 84
802.1s ● 802.3u, 802.3bz Agency compliance The N3200-ON/E3200-ON Series switch is designed to comply with the following safety and agency and used in accordance to the instructions, it may cause harmful interference to order to meet FCC emission limits. Dell is not responsible for any radio or - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 85
Community Contact Dell, EMEA - Central Dahlienweg 19 66265 Heusweiler Germany Tel: +49 172 6802630 Email: EMEA Central Sales India (N-Series only) This such trouble occurs, the user may be required to take corrective actions. NOTE: Use the AC power cords with Dell equipment only. Do not use Dell AC - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 86
Edition ● EN 60950-1, 2nd Edition ● EN 60825-1, 1st Edition ● EN 60825-1 Safety of Laser Products-Part 1: Equipment Classification Requirements and User's Guide ● EN 60825-2 Safety of Laser Products-Part 2: Safety of Optical Fibre Communication Systems ● EN 62368-1 ● FDA Regulation 21CFR 1040.10 and - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 87
scope of the WEEE, are labeled with the crossed-out wheelie-bin symbol, as shown above, as required by WEEE. For information on Dell product recycling offerings, see the WEEE Recycling instructions on Support. For more information, contact the Dell Technical Assistance Center. Specifications 87 - Dell N3200-ON | PowerSwitch N3200-ON/E3200-ON Series Installation Guide - Page 88
is valid. ONIE:/ # To access switch documentation, go to www.dell.com/manuals/ and enter your switch type. To search for drivers and downloads, go to the Drivers & Downloads tab for your switch. To participate in Dell community blogs and forums, go to www.dell.com/community. 88 Dell support
Dell PowerSwitch N3200-ON/E3200-ON
Series
Installation Guide
May 2023
Rev. A12