    2Gb SANbloc Series Installation Guide P/N: MAN-FC2002-001 Revision: 1.4 September 2003
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 2
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 3
    manual and the equipment described herein without notice. ADAPTEC has made all reasonable effort to insure that the information in this manual is accurate and complete. However, ADAPTEC a ADAPTEC 2Gb SANbloc system and is unable to resolve the problem via phone with ADAPTEC Technical Support a
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 4
    SANbloc component in question, and will then return the product to the Purchaser, freight prepaid. Cable Warranty - All ADAPTEC to connectors, adapters, and other items not a part of the basic product. ADAPTEC shall have return to ADAPTEC and installation of its replacement. On-site services are not
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 5
    at Purchaser's expense. All returned material must be accompanied by a Return Materials Authorization (RMA) number assigned by ADAPTEC. For RMA numbers contact ADAPTEC Customer Support Monday-Friday 3am-5pm PST at: Telephone: email: WWW: 321-207-2000 (RAID, FC, External Storage) 408-934-7274
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 6
    6 THE EXPRESSED WARRANTIES SET FORTH IN THIS AGREEMENT ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING W I T H O U T L I M ITAT I O N , A N Y WA R R A N T I ES O F MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, AND ALL SUCH OTHER WARRANTIES ARE HEREBY DISCLAIMED AND
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 7
    7 Table of Contents Preface 13 Audience 13 Conventions Used In This User Guide 13 Getting Support 14 FCC Statement 14 VCCI ...15 European Community Statement 15 Safety Statements 16 Chapter 1: Introduction 19 Introduction 19 Features ...19 Disk Drive Carrier 20 Power
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 8
    Host Bus Adapters 35 Supported Cables 36 Copper Cables 36 Optical Cables 36 Chapter 3: JBOD Configurations 37 Setting the Enclosure ID 37 Configurations 40 JBOD Configurations 41 Dual FC Loop Configuration 41 Quad Loop Configuration 44 Connecting a Power Source 45 Connecting an AC Power
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 9
    RAID Controller Configuration 59 Connecting a Power Source 62 Connecting an AC Power Source 62 Disk Drive Spin Up Sequence 63 Chapter System Monitoring 65 Overview 65 LS Module 65 LS Module Features 66 2Gb SANbloc Enclosure LEDs 66 Disk Drive LEDs 69 Power Supply LEDs 71 Advanced Cooling
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 10
    10 Removing a Disk Drive Carrier 77 Installing and Removing an LS Module 79 Installing an LS Module 79 Removing an LS Module 79 Installing and Removing a Power Supply 81 Installing a Power Supply 81 Removing a Power Supply 81 Installing and Removing an Advanced Cooling Module 82 Installing
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 11
    11 AC Power Supply Input 97 Temperature 97 Humidity 97 Altitude ...98 Operational Mark 99 Electromagnetic Radiation 99 Appendix C: Configuration Loop Diagrams 101 Appendix D: Upgrading a 2Gb SANbloc JBOD Array to a RAID Array 105 Equipment and parts necessary for upgrade 105 Upgrading from
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 12
    12
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 13
    describes the installation and operation of the 2Gb SANbloc Series. The following products are covered: FC2101CDT2-AC, FC2101CDR2-AC, FC2101ODT2-AC, FC2101ODR2-AC, FC2101MDT2-AC, FC2101MDR2-AC. Audience This Installation Guide is intended for use by the person installing and operating the 2Gb
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 14
    SANbloc Series you can contact our World Wide Support Centre for assistance Monday-Friday 3am to 5pm Pacific: Telephone: 321-207-2000 (RAID, FC, External Storage) 408-934-7274 (Hardware) email: ask.adaptec.com WWW http://www.adaptec.com/support accordance with the instruction manual, may cause
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 15
    for Interference by Information Technology Equipment. If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. European Community Statement This equipment complies with the following European
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 16
    16 Safety Statements The following safety statements must be read before installation. For language translations of these statements refer to Appendix B. CAUTION: This equipment is intended only for installation in a restricted access location. CAUTION: Allow disk drives and power supplies to reach
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 17
    17 CAUTION: The tower skin set is not a field replaceable unit and therefore must not be removed from the Storage Array. CAUTION: After removing the LS Module the resulting hole must be blocked, by installing a blanking plate or by installing a replacement LS Module. Failure to do so can disrupt air
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 18
    18 Safety Statements
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 19
    performance storage solution that evolves to meet your changing needs. Based on a modular, "building block" enclosure design, the 2Gb SANbloc Series offers exceptional scalability. Each enclosure supports up to 14 disk drives, or 1TB of capacity in a dense 3U form factor. As your storage needs grow
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 20
    factor. • Scalable to 8.2TB (112 drives), support for 15K rpm drives. • Enhanced enclosure services (SES) monitoring and reporting. • No single point • Dual AC power supplies. Disk Drive Carrier The disk drive carrier supports one inch, SCA-2 direct attach disk drives. The 2Gb SANbloc Series can
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 21
    21 Cooling System Cooling is provided by the two Advanced Cooling Modules (ACMs) located at the rear of the enclosure. Each of the ACM units contain two variable speed fans. The enclosure requires four fans for normal operation, but will operate correctly with one fan failed (redundancy is lost if
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 22
    22 I/O Option Modules The two rear I/O option slots (A and B) can contain a range of different option modules. The LS module will detect the type of option module installed. 1 1 2 2 I 0 I 0 I/O Option Slot B The available option modules are: I/O Option Slot A I/O Expansion Module - Copper
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 23
    RAID Controller The 2Gb SANbloc RAID Controller is a high performance controller, providing two host fibre channel and two device fibre channel interfaces. It is an intelligent, caching controller that supports RAID levels 0, 1, 3, 5, 0+1, and JBOD. The controller enables multiple hosts to access
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 24
    24 Figure 1-2: 2Gb SANbloc Series Tower Model SAN bloc Series 2Gb 0 1 2 3 4 5 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 0 1 2 3 4 5 Features
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 25
    SAN bloc Series 0 1 2 3 4 5 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F Figure 1-3: 2Gb SANbloc Series Rack Model 25 2Gb 0 1 2 3 4 5 Features
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 26
    26 Features
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 27
    27 Chapter 2: Installation and Setup This Chapter describes the installation and set up of the 2Gb SANbloc Series. Important safety instructions are discussed along with the electrical, mechanical and environmental precautions that need to be taken. Items that need to be set prior to operating the
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 28
    CAUTION 28 Safety Statements The following safety statements must be read before you install or operate the 2Gb SANbloc Series. For language translations of these statements refer to Appendix B. CAUTION: This equipment is intended only for installation in a restricted access location. CAUTION:
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 29
    29 CAUTION: It is recommended that, if interconnecting equipment resides within more than one equipment rack cabinets, these equipment racks should be at the same ground potential. WARNING: A possible shock hazard may exist in the area of the fan connection. WARNING: Disconnect the power cords
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 30
    for any signs of damage. If any damage is found the carrier and Adaptec should be informed immediately, and they will advise you of the appropriate action . Installing the System in an Equipment Rack Before installing the 2Gb SANbloc Series in an equipment rack, it is essential that the following
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 31
    are blocked, and that the system is a minimum of one meter from a solid surface such as a wall or partition. Air flow through the 2Gb SANbloc Series is from front to rear. Mechanical Loading Consideration should be given to the loading of any equipment racks. To maintain a low centre of gravity
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 32
    Electrical Considerations When installing the 2Gb SANbloc Series the following electrical considerations must do during steady state operation. Setting Fibre Channel Loop Speed (2Gb or 1Gb) The 2Gb SANbloc Series can be operated with fibre channel loop speeds of either 2Gb or 1Gb. The loop speed
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 33
    33 1Gb Operation To set the fibre channel loop speed to 1Gb operation: 1 Remove the LS module from the front of the enclosure. 2 On the LS Module locate the jumper position JP2 (Figure 2-1). 3 For 1Gb operation there should be no jumper installed at JP2. If one is installed, remove it. 4 Replace
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 34
    . CAUTION: Enclosures operating in split loop mode can not be daisy chained to other enclosures. Setting Up Split Loop Operation To operate the 2Gb SANbloc Series enclosure in split fibre channel loop mode, follow this procedure: 1 Remove the LS module from the front of the enclosure. 2 On the LS
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 35
    require 2Gb disk drives. • Disk drive blanks must be ordered for any empty drive slots. Supported Host Bus Adapters Only the following QLogic Host Bus Adapters should be used with the 2Gb SANbloc Series enclosures: • QLA-2300 (Rev. C or higher) • QLA-2310 (Rev. C or higher) Configuration Rules
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 36
    36 Supported Cables WARNING: Only the following APPROVED cables must be used with the 2Gb SANbloc Series enclosures. This section lists the cables that must be used with the 2Gb SANbloc Series enclosure. Failure to adhere to these guidelines may cause the enclosure to operate incorrectly. Copper
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 37
    is also provided along with instructions on how to set the enclosure ID. Setting the Enclosure ID Each of the fourteen disk drive slots of the 2Gb SANbloc Series has a unique identifier assigned operation is required. Note: Only QLogic 2300 and 2310 adapters should be used. Setting the Enclosure ID
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 38
    38 Figure 3-1 Location of Enclosure ID Switch 1 1 2 2 I 0 I 0 Enclosure ID Switch 1 This enclosure ID switch can be set to 0 through 7. The graphic below shows the slot number and location. Slot location when viewed from the front of the enclosure LSM Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 39
    39 Enclosure ID Drive Slot The fourteen disk drive slots (0 to 13), will be assigned an identifier based on the enclosure ID and the slot number as shown in Table 3-1. Table 3-1 Disk Drive Identifier Table 0 1 2 3 4 5 6 7 Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 40
    40 Configurations This section describes the procedures for cabling the main configurations of the 2Gb SANbloc Series JBOD. Note: The following configuration procedures refer to connecting the 2Gb SANbloc Series directly to the host system. It is also possible to connect the system using a Hub/
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 41
    JBOD Configurations There are two JBOD configurations covered in this Installation Guide: • Dual FC Loop mode (including how to daisy host: Note: You will need two HBA's in your host system, or a single HBA with support for two connections. A hub, switch or two hosts with HBA may also be used. 1
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 42
    42 To HBA Note: For details on your host and/or HBA refer to the documentation that was supplied with the host / HBA. Figure 3-2 Connecting dual FC Loop configuration to a host To HBA 1 1 2 2 I 0 I 0 See Appendix C for Loop Diagram. To daisy chain enclosures together, connect link cables from
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 43
    To HBA 43 Figure 3-3 Daisy chaining dual FC Loop enclosures To HBA 1 1 2 2 0 0 I I 1 1 2 2 0 0 I I To next enclosure See Appendix C for Loop Diagram. To next enclosure CAUTION: When daisy chaining enclosures, you must ensure that each enclosure has a unique Enclosure ID. JBOD
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 44
    44 Quad Loop Configuration To HBA Note: Quad loop configuration requires that the enclosure be configured in split loop mode. To set split loop mode, a jumper must be installed at jumper location JP3 on each LS module in the enclosure. This section describes the procedure for connecting the
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 45
    Connecting a Power Source The 2Gb SANbloc enclosure supports dual AC power supplies. Only one power supply is required for normal operation. However, a second, optional power supply may be added to provide a redundant power system. Each power supply has its own AC power inlet. CAUTION: Power supply
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 46
    numeric SEL_ID of the disk drive. Once the enclosure is powered up and all 14 drives are spun up as depicted above, the enclosure will support immediate drive spin up with two power supplies present. Modulo 8 The drive spin up sequence above uses modulo 8 to calculate the spin up delay. Modulo
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 47
    RAID Controller Introduction The 2Gb SANbloc RAID Controller is a high performance controller, providing two host fibre channel and two device fibre channel interfaces. It is an intelligent, caching controller that supports RAID levels 0, 1, 3, 5, 0+1, and JBOD. The controller enables multiple
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 48
    disk drive enclosure (device) and host as well as general support functions. It also contains the switching power supply, which generates the controller, and connections for debug and out-of-band service to the host and device PCI busses. The RAID SANbloc Series RAID Controller Introduction
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 49
    failback with multiple target ID support The I/O circuit board includes a Battery Backup Unit (BBU) that maintains memory content in case of AC power failure. Power for the I/O circuit board to the disk arrays in the 2Gb SANbloc enclosure. The controller circuit board performs these operations with a
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 50
    the interface between the enclosure and a host, as well as general support functions. The I/O circuit board provides the following: • Connections to board provides a 10BASE-T/100BASETX LAN connection for out of band service for the RAID controller. Features of the ethernet circuit board include
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 51
    51 RAID Controller Location It has a 32 bit, 33 MHz maximum PCI interface and features scatter-gather bus mastering, which enables it to perform high speed data transfers on the PCI bus. It operates in either full duplex mode or half duplex mode. It has a four wire interface to a serial EEPROM,
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 52
    52 The main parts of the RAID Controller are described in Figure 4-3. Figure 4-3 Main components of RAID controller 1 2 3 Status LEDs 4 5 6 7 FC Host Connectors (SSF optical) RS232 HSSDC Connector Ethernet Connection RAID Controller Status LEDs The RAID controller has 7 Status LEDs as shown
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 53
    a combination of the Slot number and the enclosure ID. The enclosure ID is set, using the enclosure ID switch, located on the rear of the SANbloc (see Figure 4-4). Note: The enclosure ID must be set prior to powering on the enclosure. Note: Each enclosure must have a separate ID when daisy chained
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 54
    54 Figure 4-4 Location of Enclosure ID Switch 1 1 2 2 I 0 I 0 Enclosure ID Switch 1 This enclosure ID switch can be set to 0 through 7. The graphic below shows the slot number and location. Slot location when viewed from the front of the enclosure LSM Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 55
    55 Table 6-2 Disk Drive Identifier Table Enclosure ID Drive Slot 0 1 2 3 4 5 6 7 Slot 0 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9 Slot 10 Slot 11 Slot 12 Slot 13 3 18 33 48 63 78 93 108 4 19 34 49 64 79 94 109 5 20 35 50 65 80 95 110 6 21 36 51 66 81 96 111 7 22 37
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 56
    enclosure's I/O slot. The second I/O slot must contain an I/O module or a blank plate. Note: The following configuration procedures refer to connecting the 2Gb SANbloc Series directly to the host system. It is also possible to connect the system using a Hub/ Switch. CAUTION: Before working on the
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 57
    57 Figure 4-5 Single RAID Controller to Host Connector HBA 1 1 1 HBA 2 2 21 2 3 4 5 6 7 I 0 I 0 Daisy Chaining a Single Controller Enclosure To daisy chain the RAID enclosure to an expansion enclosure, connect link cables from the RAID controller to the top connectors of the I/O
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 58
    58 I/O Module Figure 4-6 Daisy Chaining Single Controller Enclosure RAID Controller HBA 1 1 1 HBA 2 2 2 1 2 3 4 5 6 7 0 0 I I Link Cable Connect this cable for dual loop operation 1 2 Link Cable 1 2 0 0 I I To next enclosure Total of 8 enclosures may be daisy chained
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 59
    59 In this configuration two RAID Controllers are installed in the enclosures I/O slots. Note: The following configuration procedures refer to connecting the 2Gb SANbloc Series directly to the host system. It is also possible to connect the system using a Hub/ Switch. CAUTION: Before working on the
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 60
    60 Host B HBA 1 HBA 2 1 2 3 4 5 6 7 Figure 4-7 Dual RAID Controller Configuration 1 1 2 2 1 2 3 4 5 6 7 Host A HBA 1 HBA 2 I 0 I 0 Daisy Chaining a Dual Controller Enclosure To daisy chain the RAID enclosure to an expansion enclosure, connect link cables from the RAID enclosure to the
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 61
    Host B HBA 1 HBA 2 1 2 3 4 5 6 7 61 Figure 4-8 Daisy Chaining a Dual Controller Enclosure Host A HBA 1 1 1 HBA 2 2 2 1 2 3 4 5 6 7 0 0 I I Link Cable 1 2 Link Cable 1 2 0 0 I I To next enclosure Total of 8 enclosures may be daisy chained together. To next enclosure
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 62
    Connecting a Power Source The 2Gb SANbloc enclosure supports dual AC power supplies. Only one power supply is required for normal operation. However, a second, optional, power supply may be added to provide a redundant power system. Each power supply has its own AC power inlet. CAUTION: Power supply
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 63
    numeric SEL_ID of the disk drive. Once the enclosure is powered up and all 14 drives are spun up as depicted above, the enclosure will support immediate drive spin up with two power supplies present. Modulo 8 The drive spin up sequence above uses modulo 8 to calculate the spin up delay. Modulo
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 64
    64 Disk Drive Spin Up Sequence
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 65
    . LS Module The LS Module (Loop Resiliency and SES Module) provides monitoring and control for the 2Gb SANbloc Series. The module reports status and receives control information over the Enclosure Services Interface (ESI) port of any of the fourteen disk drives installed in the enclosure. The LS
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 66
    memory for the microcontroller • Temperature sensor • Audible alarm with manual and software disable • FC link monitoring and status information and module status • I/O option slot status monitoring 2Gb SANbloc Enclosure LEDs The 2Gb SANbloc Series has six LEDs located on each of the front
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 67
    67 Figure 5-1 Location of 2Gb SANbloc Enclosure LEDs SAN bloc Series 0 1 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 2 3 4 5 2Gb 0 1 2 3 4 5 LED 0 0 LED 1 1 LED 2 2 LED 3 3 LED 4
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 68
    68 Table 5-1 Enclosure LED Descriptions LED 0 LED 1 LED 2 LED 3 LED 4 LED 5 Description Color Indication Power On Shelf Fault Green Amber FC Loop A FC Loop B LS Fault Green Green Amber 2Gb Operation Green Normally ON, indicates power is applied. OFF indicates no power. Normally OFF
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 69
    69 Disk Drive LEDs Each disk drive carrier has two LED indicators visible from the front of the 2Gb SANbloc enclosure. The green disk drive ready LED is controlled by the disk drive, and the bi-colour LED is controlled by the LS Module. The
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 70
    70 Figure 5-2 Disk Drive Carrier LEDs Disk Drive Ready (Green) BiColor LED (Green/Amber) 18F Disk Drive LEDs
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 71
    71 Power Supply LEDs The 2Gb SANbloc Series uses two AC power supplies. The AC power supplies provide 853W peak output power and 673W continuous output power. The 2Gb SANbloc Series power supply has two LED indicators on it, which are visible from the rear of the enclosure. The green Power OK LED is
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 72
    has two variable speed fans per advanced cooling module. Each of the two ACMs on the rear of the 2Gb SANbloc Series enclosure has two fault LEDs visible from the rear of the enclosure. The LEDs are labeled "1" and "2" to correspond with the two fans inside
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 73
    73 RAID Controller LEDs The RAID controller has 7 LEDs located and numbered as shown. Figure 5-5 RAID controller LEDs 1 2 3 Status LEDs 4 5 6 7 FC Host Connectors (SSF optical) RS232 HSSDC Connector Ethernet Connection The table below describes the LEDs meaning. Table 5-3 Controller Status LEDs
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 74
    74 RAID Controller LEDs
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 75
    75 Chapter 6: Installing and Removing Components This Chapter describes the procedures for installing and removing the replaceable components in the 2Gb SANbloc Series. WARNING: The module handles are to facilitate the easy insertion and removal of the modules, they should not be used to lift and/or
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 76
    76 Location of the Components SAN bloc Series 0 1 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 18F 2 3 4 5 2Gb 0 1 2 3 4 5 LS Module Disk Drives ACMs 1 2 LS Module 1 2 I 0 I 0 I/O Module/ RAID Controller Power Supplies I/O Module/ RAID Controller Location of the
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 77
    , and the drive locked in place, when the lever "clicks" into position. Removing a Disk Drive Carrier 1 Using your finger, release the locking tab by pressing it in the direction shown in Figure 5-1, and pull the cam lever towards you. 2 Fully open the cam lever. (approx. 90o to enclosure). 3 With
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 78
    18F 78 Figure 6-1 Disk Drive Carrier Push locking tab in this direction to open Cam Lever Installing and Removing a Disk Drive Carrier
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 79
    , and the LS Module locked in place, when the lever "clicks" into position. Removing an LS Module 1 Using your finger, release the locking tab by pressing it in the direction shown in Figure 5-2, and pull the cam lever towards you. 2 Fully open the cam lever (approx. 90o to enclosure). 3 Gently
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 80
    80 Figure 6-2 LS Module Push locking tab in this direction to open 0 1 2 3 4 5 Cam Lever Installing and Removing an LS Module
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 81
    it out of the enclosure. CAUTION: Immediately replace the power supply carrier or install a power supply carrier blank to maintain correct airflow. Figure 6-3 Power Supply I 0 AC Inlet Handle On/Off Switch Installing and Removing a Power Supply
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 82
    82 Installing and Removing an Advanced Cooling Module The advanced cooling modules are located in the rear of the enclosure. Follow these procedures to install and remove the advanced cooling modules. Installing an Advanced Cooling Module 1 Select the advanced cooling module slot into which the
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 83
    83 Installing and Removing an I/O Module/RAID Controller Note: In the following section, "I/O Module" is taken to include the RAID Controller in addition to the I/O Module. Installing an I/O Module/RAID Controller Removing an I/O Module/RAID Controller The I/O module is located in the rear of
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 84
    84 Installing and Removing an I/O Module/RAID Controller
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 85
    CAUTION 85 Appendix A: Safety Statement Translations CAUTION: This equipment is intended only for installation in a restricted access location. ACHTUNG: Dieses Gerät sollte nur an einem Ort mit Zugangskontrolle installiert werden. FÖRSIKTIGHET: Denna utrustning får endast installeras på ställe med
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 86
    CAUTION 86 CAUTION: Allow disk drives and power supplies to reach room ambient temperature before powering on the shelf. ACHTUNG: Ehe Laufwerke und Netzteile an die Stromversorgung angeschlossen werden, sollten sie sich an die Raumtemperatur angepasst haben. FÖRSIKTIGHET: Låt skivdrivenheter och
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 87
    CAUTION 87 CAUTION: It is recommended that if interconnecting equipment resides within more than one equipment rack cabinet, these rack cabinets should be at the same ground potential. ACHTUNG: Befinden sich Verbindungselemente in mehr als einem Rack-Gehäuse, sollten die Racks dasselbe
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 88
    CAUTION 88 CAUTION: Before attempting to install or remove any of the components, ensure that anti-static precautions have been taken. The minimum requirement is a properly grounded antistatic wrist strap and grounding wire. ACHTUNG: Vor dem Entfernen oder Installieren einer Komponente sollte
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 89
    CAUTION 89 trisitet. Minimumskravet er riktig jordet antistatisk håndleddstropp og jordingsledning. CAUTION: When installing or removing a rackmount shelf, remove all power supplies and disk drives. It is recommended that you work with at least one other person when installing a disk shelf. This is
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 90
    CAUTION 90 FORSIGTIG: Når en rackmonteret hylde installeres eller fjernes, skal al strømforsyning og alle drev fjernes. Det anbefales, at der mindst er én anden person til stede, når en drevhylde installeres. Det er nødvendigt for at undgå personskade og beskadigelse af hylden. OBS: Når hylle for
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 91
    CAUTION 91 CAUTION: The tower skin set is not a field replaceable unit and therefore must not be removed from the Storage Array. ACHTUNG: Das Tower-Gehäuse kann nicht am Einsatzort ausgetauscht werden und sollte deshalb nicht entfernt werden. FÖRSIKTIGHET: Det yttre höljet är inte en utbytbar enhet
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 92
    CAUTION 92 CAUTION: After removing the LS Module the resulting hole must be blocked by installing a blanking plate or by installing a replacement LS Module. Failure to do this can disrupt airflow and seriously reduce cooling. ACHTUNG: Nach dem Entfernen des LS Module muss die entstehende Lücke
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 93
    WARNING 93 OBS: Når en LS Module er fjernet, må hullet blokkeres ved å installere en maskeringsplate eller ved å sette inn en annen LS Module. Dersom dette ikke gjøres, kan det forstyrre lufttilstrømningen og gi sterkt redusert kjøling. WARNING: A possible shock hazard may exist in the area of the
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 94
    94
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 95
    two Fibre Channel interfaces, 200MB\s each, 400 MB\s total. • External hub and switch support. Disk Drive Interface • Dual independent Fibre Channel interfaces, 200MB\s each, 400MB\s total. System . • Up to 14 disk drives, removable from the front. • Two independent AC power inlets. Host Interface
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 96
    96 Physical Dimensions Deskside Enclosure Height: 20 inches (50.8cm) Width: 9 inches (22.9cm) Depth: 20 inches (50.8cm) Weight: 60 lbs (29.5kg) maximum Rack Enclosure Height: 5.22 inches (13.3cm) Width: 17.5 inches (44.5cm) Depth: 20 inches (50.8cm) Weight: 60 lbs (29.5kg) maximum Warranty
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 97
    97 Disk Drives Power Supply AC Power Supply Input Temperature Humidity Rotational Velocity: Form factor: Height: Interface: 10K; 15K 3.5" 1.0" Fibre Channel (2Gb FC support) Input Voltage: Current Rating Input Frequency: Max. Peak Output Power Max. Average Output Power 85 - 264 VAC 10 - 5 Amps
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 98
    98 Altitude • Altitude Operating: -200 to 10,000 feet • Altitude Storage: -200 to 40,000 feet Operational Shock Half sine shock: 3G half sine shock with a pulse duration of 11 milliseconds or less. No permanent damage will occur at or below this level. Operational Vibration Sinusoidal vibration
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 99
    99 Regulatory Agency Compliance Product Safety Standards • UL1950 Information Technology Equipment (US) • CSA C22.2 No 950 Information Technology Equipment (Canadian Law) • EN 60950 Information Technology Equipment (European Norm) Product Safety Third Party Certifications • UL Listed USA • CSA
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 100
    100 Regulatory Agency Compliance
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 101
    101 Appendix C: Configuration Loop Diagrams External Loop Diagram for a Single Enclosure System - Single Loop 3 4 5 6 7 8 9 Enclosure ID 0 16 15 14 13 10 12 11 Circles denote disk drives with drive ID shown.
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 102
    102 External Loop Diagram for a Dual Enclosure System - Single Loop 3 4 5 6 7 8 9 Enclosure ID 0 16 15 14 13 10 12 11 18 19 20 21 22 23 24 Enclosure ID 1 25 31 30 29 28 27 26 Circles denote disk drives with drive ID shown.
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 103
    103 External Loop Diagram for a Single Enclosure System - Dual Loop 3 4 5 6 7 8 9 Enclosure ID 0 16 15 14 13 10 12 11 Circles denote disk drives with drive ID shown.
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 104
    104 External Loop Diagram for a Dual Enclosure System - Dual Loop 3 4 5 6 7 8 9 Enclosure ID 0 10 16 15 14 13 12 11 18 19 20 21 22 23 24 Enclosure ID 1 25 31 30 29 28 27 26 Circles denote disk drives with drive ID shown.
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 105
    for the upgrade from JBOD to RAID: • Anti-static wrist strap and properly earthed grounding wire. • Phillips head screw driver. • 2Gb SANbloc RAID Controller (2 controllers if dual controller operation is required) • FC host cables to connect RAID controller to host/hub/switch Upgrading from JBOD
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 106
    I I 0 0 106 driver. 1 2 RAID Controller Installed 1 2 1 2 3 4 5 6 7 RAID Controller Screws 0 I 5 If you are upgrading to a dual RAID configuration then repeat steps 2 through 4 to install the second RAID controller. 6 Attach the host cable(s) to the host connector on the RAID
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 107
    107 Installing the Battery Backup Unit The battery backup unit (BBU) for the RAID controller is installed on the ACM unit (see Figure D-1). Figure D-1 Location of Battery Backup Unit on ACM BBU goes here ACM Assembly Follow this procedure to install the Battery Backup Unit (BBU): 1 Remove the
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 108
    and attach to the connector Tabs Tabs BBU 4 Feed the BBU cable through the hole provided and connect it to the BBU connector (see Figure D-2). 5 Press the BBU into position and secure it by ensuring the four tabs "click" into place. 6 Replace the ACM in the enclosure and tighten the ACM
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 109
    A advanced cooling module, leds, 72 advanced cooling modules, 21, 81, 82 air flow, 31 ambient temperature, 30 audience, 13 B battery backup unit (BBU) 107 battery backup unit, location 107 C cabling, dual i/o module, 41 circuit overloading, 32 communication, esi, 65 compliance, agency, 99
  • Adaptec FC2101CDR2-AC | Installation Guide - Page 110
    shock, operational, 98 single i/o module, configuration, 41 single raid controller configuration 56 specifications, technical, 95 spin up sequence 46, 63 support, 5, 14 T technical specifications, 95 temperature, 30, 97 translations, safety statements, 85 U unpacking, 30 upgrading jbod to raid 105
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

2Gb SANbloc Series
Installation Guide
P/N: MAN-FC2002-001
Revision: 1.
4
September
200
3