Acer P1200 Acer P1200i Projector Service Guide - Page 69
PC MODE, Frequency and Tracking Boundary - manual
View all Acer P1200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 69 highlights
4-6 PC MODE Note: - When getting into function test, adjust "Zoom Ring" to guarantee the lens at the highest state and the image maximum, and adjust the focus to guarantee the image at the clearest, then start test. - Test signal: 1024(H) x 768(V) (P1200i/P1200B) 800(H) x 600(V) (P1100C) - Here we take P1200i for example. 1. Frequency and Tracking Boundary Procedure Inspection item Criteria - Test equipment: video generator - Test signal: 1024(H) x 768(V) - Test Pattern: General-1 or Master - Check and see if the image sharpness is well performed. - If not, re-adjust by the following steps: (1) S elect "Frequency" function to adjust the total pixel number of pixel clock in one line period. (2) S elect "Tracking" function and use right or left arrow key to adjust the value to minimize video flicker. - Adjust Resync or Frequency/Tracking/H. Position/V. Position to the inner screen. - Eliminate visual wavy noise by Resync, Frequency or Tracking selection. - Check if there is noise on the screen. - Horizontal and vertical position of the video should be adjustable to the screen frame. - If there is noise on the screen, the product is considered as failure product. - If there is noise on the screen, use auto or manual "frequency" function or "tracking" function to adjust the screen. - The PC mode functionally sure be workable include support format with frequency and auto detected functional will be workable. General-1 Master P1100C/P1200i/P1200B Confidential 4-