Fluke TiS75 Product Manual

Fluke TiS75 Manual

Fluke TiS75 manual content summary:

  • Fluke TiS75 | Product Manual - Page 1
    TiS55+/TiS75+ Thermal Imager Users Manual É October 2020 (English) © 2020 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. MyFlukeStore Shop for Fluke products online at: www. .com 1.888.
  • Fluke TiS75 | Product Manual - Page 2
    not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available
  • Fluke TiS75 | Product Manual - Page 3
    Table of Contents Title Page Introduction...1 Contact Fluke Corporation 1 Safety Information 2 Product Familiarization 2 Features ...2 The 18 Display Menu ...19 Marker ...19 Delta-T...20 Spot Box ...20 Fluke Connect Menu 21 Asset Identification (Asset ID 22 Assign Asset ID Tag with a
  • Fluke TiS75 | Product Manual - Page 4
    TiS55+/TiS75+ Users Manual Assign a Different Asset ID Tag 23 Fluke Connect Tools 23 Connection Icons 24 Save Images to Fluke Connect Cloud 25 Sign in to Fluke Connect WiFi Network 25 Sign out of Fluke Connect WiFi Network 26 Sign in to Fluke Connect Cloud 26 Sign out of Fluke Connect Cloud
  • Fluke TiS75 | Product Manual - Page 5
    Battery Charger Base 45 AC Power Socket on Imager 45 Optional 12 V Vehicle Charger 46 Radio Frequency Data 46 Specifications ...46 iii MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 6
    Introduction The Fluke TiS55+/TiS75+ Thermal Imagers (the Product or Imager) are handheld, infrared imaging cameras for use in many applications. These applications include equipment troubleshooting, preventive and predictive maintenance, building diagnostics, and research and development. The
  • Fluke TiS75 | Product Manual - Page 7
    of the Imager. Table 1. Features Feature TiS55+ TiS75+ Focus/Image Enhancement Advanced manual focus EdgeSharp Technology IR-Fusion Technology                  3 5 3 5    2 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 8
    WiFi Bluetooth Fluke Connect Connect to Fluke tools Fluke Connect/desktop software Stream video (radiometric streaming) The Product Table 2 shows the front of the Product. Table 2. Front 3 2 Thermal Imager Product Familiarization TiS55+    TiS75+     7 8 9 4 5 1 6 Item
  • Fluke TiS75 | Product Manual - Page 9
    TiS55+/TiS75+ Users Manual Table 3 shows the back of the Product. Table 3. Back 10 19 11 12 13 14 15 16 18 17 Item J K L M N Description Retractable Lens Cover Infrared Camera Lens Visual Light Camera Lens Laser Pointer Secondary Trigger Item O P Q R S Description Primary Trigger Manual
  • Fluke TiS75 | Product Manual - Page 10
    Menu (Memory Gallery). Push to move the cursor and highlight an option. With Level/Span set to Manual, push to adjust the Level and Span. See Level/Span. With Level/Span set to Auto, push to move the marker. See Marker. 5 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 11
    TiS55+/TiS75+ Users Manual Touch Screen (Display) The touch screen is the primary user interface of the Product. The touch screen has a the main menu. 2. Tap an icon on the main menu to open a sub-menu. See Table 7. 6 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 12
    . Add or remove an asset ID tag. See Asset Identification (Asset ID). Toggle to add or remove a flag. See Flag an Image. 7 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 13
    TiS55+/TiS75+ Users Manual Basic Operation Turn On Manual Focus Control until the inspection object is in proper focus. To simulate fixed focus at 1.2 m, align the raised bar on the focus control with the marker on the case. See Figure 1. Figure 1. Fixed Focus 1.2 m 8 MyFlukeStore Shop for Fluke
  • Fluke TiS75 | Product Manual - Page 14
    ID, or tap Remove Asset ID to remove an asset ID tag from the image. See Asset Identification (Asset ID). 4. Tap Save. 9 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 15
    TiS55+/TiS75+ Users Manual Save Image To save an Product. b. Copy and paste or drag the images to a directory on the PC. 4. Remove the USB cord from the PC and the Product. To save images to a PC from the memory card: . 10 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 16
    M Display Set the features to show on the display. See Display Menu. Save images over a WiFi connection. See Fluke Connect Menu. F Fluke Connect Note The Fluke Connect system is not available in all countries. S Device Settings Set user preferences and view information about the Product. See
  • Fluke TiS75 | Product Manual - Page 17
    TiS55+/TiS75+ Users Manual Measurement Menu Table 8 is a list of the options available in the Measurement menu. Table 8. Measurement Menu Option Menu Level/Span Emissivity Option Auto Manual Set Level/Span Custom Value Description Sets the Level/Span to adjust automatically or manually
  • Fluke TiS75 | Product Manual - Page 18
    sets Level/Span based on the total temperature range. With Level/Span set to Manual, the level setting moves the thermal span up or down within the total temperature range. move the span to a lower temperature level. 13 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 19
    TiS55+/TiS75+ Users Manual The scale along the right side of the display shows the thermal span increasing or decreasing even when adjustments to the emissivity and reflected background adjustments are performed properly. 14 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 20
    the window, adjust the transmission percentage in the Imager or in Fluke Connect desktop software to improve the accuracy of the measurement. When you do a visible image with every infrared image to show where a potential problem might be. See IR-FusionTM Technology Shows the infrared image imposed
  • Fluke TiS75 | Product Manual - Page 21
    TiS55+/TiS75+ Users Manual IR-FusionTM Technology IR-FusionTM technology makes it potential problem might be, and then allows you to more effectively communicate it to others. Note The visible image and infrared image can be customized or separated in SmartView and Fluke Connect Software when
  • Fluke TiS75 | Product Manual - Page 22
    or areas that are below the calculated dew point. Use the arrows to adjust the ambient temperature and the relative humidity. 17 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 23
    TiS55+/TiS75+ Users Manual Note On the TiS55+, you can use the low-temperature color alarm function as a dew point color alarm. Determine and to the selected palette. See Figure 3. Figure 3. Palette and Range Bar Selection 18 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 24
    Display Menu Thermal Imager Display Menu Use the Display menu to set which features show on the display. To show the Fluke logo on the display, see Settings Menu. Table 12 lists the options in the Display menu. Table 12. Display Menu Option Description Spot Temp (Min/
  • Fluke TiS75 | Product Manual - Page 25
    TiS55+/TiS75+ Users Manual Delta-T Use Delta-T to set the center point or a spot marker to use as a temperature reference mark. The Box. Or, Push: • W to decrease the vertical size. • X to increase the vertical size. 20 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 26
    Option Menu Option Description Assign images to an asset. Scan Asset ID NA Save Images to Fluke Connect Cloud WiFi WiFi Network Sign in to Scan a QR code or barcode attached to an asset or manually enter an asset identification. See Asset Identification (Asset ID). Turn on or turn off WiFi
  • Fluke TiS75 | Product Manual - Page 27
    TiS55+/TiS75+ Users Manual Asset Identification (Asset ID) Use Asset ID to save and organize images by asset like a motor or electrical panel. Use returns to camera mode, and the asset ID does not show on the display. 22 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 28
    tools to: • View the live measurement of each tool. • Capture the measurement of each tool in .is2 and .is3 images. To discover a Fluke Connect-supported tool: 1. Turn on each wireless tool and make sure the wireless feature is enabled. See the documentation of each tool for more information
  • Fluke TiS75 | Product Manual - Page 29
    TiS55+/TiS75+ Users Manual To disconnect from a connected tool: 1. On the Imager, tap connect to a Fluke Connect account. Or, Images are saving to a Fluke Connect account. WiFi is on, and the Product is connected to a Fluke Connect account. The Product is not connected to a Fluke Connect account.
  • Fluke TiS75 | Product Manual - Page 30
    Connect Instant Upload, the images you take with the Product automatically upload to your Fluke Connect account in the Fluke Cloud. You can view the images saved in the Fluke Cloud on the Fluke Connect website without the mobile device and Product connected to each other. Note The Instant Upload
  • Fluke TiS75 | Product Manual - Page 31
    TiS55+/TiS75+ Users Manual Sign out of Fluke Connect WiFi Network To sign out of a WiFi network: 1. Select F > Save Images to Fluke Connect Cloud > WiFi Network. 2. Tap the name of the connected network. 3. Tap Forget Network. 4. Tap F to return to camera mode. Sign in to Fluke Connect Cloud To sign
  • Fluke TiS75 | Product Manual - Page 32
    Wireless System Thermal Imager Fluke Connect Menu The Product supports the Fluke Connect Wireless System. The Fluke Connect system wirelessly connects your Fluke test tools with an app on a mobile device. It shows images from the Product on your mobile device. Note The Fluke Connect system is not
  • Fluke TiS75 | Product Manual - Page 33
    TiS55+/TiS75+ Users Manual a. Go to Settings > Wi-Fi. b. Select the Wi-Fi network that begins with Fluke.... 3. On the Fluke Connect app, select Thermal Imager from the list. The pictures you take with the Product are saved on your mobile device and on the Product. Note To save images to the Fluke
  • Fluke TiS75 | Product Manual - Page 34
    Connect Menu b. Tap Next. c. Use the keyboard to enter a password. d. Tap Sign In. e. Tap OK. The display returns to the Save to Fluke Connect menu. 5. Sign in to a shared folder. See Sign in to Shared Folder. Sign out of Shared Folder WiFi Network To sign out: 1. Select F > Save
  • Fluke TiS75 | Product Manual - Page 35
    TiS55+/TiS75+ Users Manual 4. Tap Save. Depending on your security environment, enter a username and password: a. Tap Username and Password. b. Use the to the Save to Shared Folder menu. 2. Tap F to return to camera mode. 30 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 36
    from the IR-PhotoNotes photo annotation system into a single file. To customize or separate the visible and infrared images, use SmartView software or the Fluke Connect app. Saves images as a .jpg file. Units Distance JPEG Visible Light Camera Resolution Units Choose the .jpg file
  • Fluke TiS75 | Product Manual - Page 37
    TiS55+/TiS75+ Users Manual Table Use the QR code reader for Asset Tagging. Logo NA Show or hide the Fluke logo on the display. Language Set the language to use on the display the version, certificates, and Open Source Software Licenses of the Imager. Version NA Firmware version of
  • Fluke TiS75 | Product Manual - Page 38
    the .is3 video format when video modification and IS3 maximum resolution is needed. Video File Fomat To edit the .is3 video file, use SmartView software or the Fluke Connect app. Save videos as an .avi file with .mpeg encoding. AVI Choose the .avi video format when video modification is not
  • Fluke TiS75 | Product Manual - Page 39
    TiS55+/TiS75+ Users Manual View Video To play a video: 1. Push m. 2. Select a file to play. All video files point where the temperature will be monitored. • To start the Auto Capture manually, select Manual Trigger. Start manual trigger Auto Capture: 1. Select s > Capture Settings > Start Capture.
  • Fluke TiS75 | Product Manual - Page 40
    or spot box reaches the trigger condition. Bluetooth Headset Connect a Bluetooth Headset to support audio features. To connect a Bluetooth Headset: 1. Put the Bluetooth Headset into pairing the date and exit the menu. 35 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 41
    TiS55+/TiS75+ Users Manual Time Time shows as: 24 hour or 12 hour. To set the time format: 1. Select s > Time. 2. Select 24 hour or needed, tap first. If no notes are saved with the image, a keyboard opens on the display. 36 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 42
    m > image > ... > Audio Note. 1. Tap Record and begin recording. You can record up to 60 seconds of audio. To cancel, tap Cancel. 37 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 43
    TiS55+/TiS75+ Users Manual 2. To pause, tap Pause. You can save or playback while the recording is paused. • To save, tap Save. The recording files at a later time. Images that have IR-PhotoNotes show with the icon (C). 38 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 44
    image. 1. For each image to save, push the primary trigger to take an image. Note The TiS55+ can take one IR-PhotoNote only. Thermal Imager Image Annotation 2. To stop taking images and return again to remove the flag. 39 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 45
    TiS55+/TiS75+ Users Manual Manage Images You can delete images from Memory or during review. Delete an Image To delete only one delete all of the images at the same time: 1. Select m > > Delete All Images. 2. Tap Delete. 40 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 46
    Image is saving to a shared folder Image saved to a shared folder Image is not saved. Return to WiFi range to save. 41 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 47
    TiS55+/TiS75+ Users Manual View Image To open an image in fullscreen mode: 1. Push m. 2. If image in fullscreen mode, and the asset ID does not show on the display. Fluke Connect Desktop Software Fluke Connect desktop software for a PC is available to use with the Product and contains features to
  • Fluke TiS75 | Product Manual - Page 48
    , follow the instructions to install Fluke Connect software. 4. Administrator privileges are required for the installation. 5. Restart the PC when installation is complete. Update Firmware To update the firmware: 1. On the PC, open Fluke Connect software. 2. Connect one end of the USB cord into your
  • Fluke TiS75 | Product Manual - Page 49
    TiS55+/TiS75+ Users Manual Maintenance The Product requires minimum maintenance. Clean the Case Clean the case with a damp cloth and a weak life. Without use, the battery will self-discharge in approximately six months. 44 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 50
    Imager. bz flashes on the display while the battery charges. 2. Charge until the charge indicator on the display does not flash. 45 MyFlukeStore Shop for Fluke products online at: www. .com 1.888.610.7664
  • Fluke TiS75 | Product Manual - Page 51
    TiS55+/TiS75+ Users Manual If you remove the Imager from the charger before a full charge shows, it can have and Imager when battery is fully charged. Radio Frequency Data See Table 15 for instructions on how to access digital copies of the Certificate IDs on the Imager. 46 MyFlukeStore Shop for
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

TiS55+/TiS75+
Thermal Imager
Users Manual
É
October 2020
(English)
© 2020 Fluke Corporation. All rights reserved.
Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore
.com